05-08-2015
device datasheet
Thank you all for your time and help. The device is a programmer NEC have a communication for the console so I want to send and receive text lines.
Serial interface (RS-232C) capable of handling communication at 9,600 (minimum) baud up to 115,200 baud. The DB-9 (female) PINOUT is configured this way:
SERIAL HOST -----------SIGNAL NAME
1------------------------------NC
2------------------------------RxD
3------------------------------TxD
4------------------------------NC
5------------------------------Vss (GND)
6------------------------------NC
7------------------------------RTS
8------------------------------CTS
9------------------------------NC
The RS-232C data transfer conditions are 9,600 baud, 8 data bits, 1 stop bit, no parity and selectable hardware handshake. The baud rate may be selected from 9,600 bps (default), 19,200 bps, 38,400 bps, 57,600 bps or 115,200 bps.
This is information about the device:
[URL="http://documentation.renesas.com/doc/DocumentServer/U15260EJ4V0UM00.pdf"]
Excuse, I'm new in UNIX, I'm trying learn.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
We're running SCO Unix Openserver 5.05 and I'm having trouble with serial communication between the com2 serial port and a handheld device. Downloading data from Unix to the handheld works perfectly, but the other way around creates a major problem. I don't know whether it's a buffer overflow or... (1 Reply)
Discussion started by: Aretha
1 Replies
2. UNIX for Advanced & Expert Users
Hi,
I am working on serial communication on Unix. Can anyone guide me through it. The steps required for RS 232 communication and can i do serial communication even if i dont have super user previledges.
Thankx,
Vicky (1 Reply)
Discussion started by: Vicky
1 Replies
3. UNIX for Dummies Questions & Answers
This isn't really a unix question, or even a programming question, but I hope you guys can help. I want to create a program to control the electricity on a model railway.
I have created the program to that it sends characters over the serial cable, but now I need to do the switch that will... (1 Reply)
Discussion started by: KrazyGuyPaul
1 Replies
4. IP Networking
I have serial modem connection between two computers. We have to login the remote computer through ip address. How can I get the ip address in this connection? (1 Reply)
Discussion started by: pcsaji
1 Replies
5. Programming
hello,
I am gettin problem while sending and recieving data through seial port...
when I am sending Data then the reciever end is not able to recieve that data .....
Reciever end is running in infinite loop just polling after some time to check that there is data on the port and then again... (9 Replies)
Discussion started by: arunchaudhary19
9 Replies
6. OS X (Apple)
Hi again,
I spoke with Keyspan and they assured me the USB to Serial device was working if I could use the Screen tool.
I asked why I was unable to redirect stdin/stdout to and from the /dev/tty. device and was told there was no reason I shouldn't be able to do so.
I have tried:
... (1 Reply)
Discussion started by: cpfogarty
1 Replies
7. Shell Programming and Scripting
Hi there
how can i get the result of a command to not give me its error. For example, on certain systems the 'zfs' command below is not available, but this is fine becaues I am testing against $? so i dont want to see the message " command not found" Ive tried outputting to /dev/null 2>&1 to no... (5 Replies)
Discussion started by: hcclnoodles
5 Replies
8. Ubuntu
Hello!
I am working on an application which reads environmental instruments which have serial ports. The application requires a serial port to be present to talk to the device (i.e. /dev/ttyS0 ). In some instances the environmental devices will be 100's of yards away from the computer, so a... (5 Replies)
Discussion started by: mvona
5 Replies
9. Programming
edit: never mind; mods please delete. I finally got so frustrated I figured it couldn't be the code and it must be the device on the other end. After pulling it out of its cradle, I realized it was a different model number than the one I was using before, and wasn't accepting my... (1 Reply)
Discussion started by: DreamWarrior
1 Replies
10. UNIX for Dummies Questions & Answers
Hey, I'm completely new at this and I was wondering if there is a way that I would be able to redirect the log files in a directories standard output and standard error into and excel spreadsheet in anyway?
Please remember don't use too advanced of terminology as I just started using shell... (6 Replies)
Discussion started by: killaram
6 Replies
ports(7) Miscellaneous Information Manual ports(7)
NAME
ports, port_names - Device (tty and lp) names for serial and parallel ports
SYNOPSIS
Default Serial Ports:
/dev/tty00
/dev/tty01 (not present on a single-port system)
Parallel Port:
/dev/lp0
DESCRIPTION
AlphaStation and AlphaServer systems provide one or two 9-pin serial communication ports. These ports are usually labelled 1 (COMM1) and 2
(COMM2), but they may be identified by different icons. Using the appropriate serial cable and terminator, you can connect a serial
printer, external modem, or character-cell terminal to a serial port. Most AlphaStation and AlphaServer systems also provide one parallel
port, for use with a parallel printer.
When you add a device to your system, the installation documentation may instruct you to map the device pathname to the port. These
devices are located in the /dev directory.
For serial-line ports, the two default device pathnames are: This pathname always maps to 1, COMM1, the lowest port number, an icon for a
terminal console, or the only serial port (on a single-port system). This pathname always maps to 2, COMM2, the next numbered port, or (if
one serial port is labeled with an icon for a terminal console) the remaining serial port.
If your system hardware has been extended to include additional serial ports, the pathnames /dev/tty02, /dev/tty03, and so forth, may also
be available to you. However, most systems have only /dev/tty00 and /dev/tty01 as the device pathnames for serial ports.
The one parallel port on an AlphaStation or AlphaServer may be labeled with the word printer or a printer icon. On some systems, the paral-
lel port may not be labeled. The device pathname for the parallel port is /dev/lp0. Currently, Tru64 UNIX does not fully support parallel
printers, so fewer devices are connected to this port as compared to serial ports.
If you are connecting a terminal console to your system, it must be connected to the serial port mapped to /dev/tty00. For other serial
devices, it does not matter which of the serial ports you choose for the connection. For example, suppose you are setting up a system that
has two serial ports, labeled 1 and 2. You intend to use a serial-line terminal rather than a workstation monitor as the system console and
also want to connect a serial-line printer to the system. In this case, you must connect the terminal to the port labeled 1 (with the
device pathname /dev/tty00). Therefore, you must connect the printer to the remaining port labeled 2 (with the device pathname /dev/tty01).
If, for the same type of system, you intend to use a workstation monitor as the system console, it does not matter which serial port you
use for a serial-line printer or modem. In other words, you can connect the printer to either port 1 (with pathname /dev/tty00) or port 2
(with pathname /dev/tty01). When prompted to enter a /dev/tty** pathname by the lprsetup script or the Print configuration tool in the CDE
Application Manager, you would specify /dev/tty00 if you connected the printer to port 1 or /dev/tty01 if you connected the printer to port
2.
See the System Administration manual for more information on setting up consoles (including remote consoles) and printers. See the
modem(7) reference page for more information on setting up modems.
SEE ALSO
Commands: lprsetup(8)
Devices: ace(7), modem(7)
System Administration delim off
ports(7)