03-24-2015
Is autonegotiation enabled?
10 More Discussions You Might Find Interesting
1. Programming
Hi all,
Can someone advice, why I'm getting a segmentation fault on a Linux system for a program which looks like the below one--:
typedef struct idev{
int p,
char q;
} Idev;
typedef struct abc{
int i;
Idev *idev_ptr;
} ABC;
int main(){
ABC a_var;
char str;
int... (4 Replies)
Discussion started by: Praveen_218
4 Replies
2. Solaris
Is there a limit to the number of LUNS that can be concatenated using Solaris Volume manager with Soft partitions?
I have worked with some AIX admins in the past and there was such a limitation therefore limiting the size the filesystem could grow to.
Is there such a limitation in Solaris 9... (6 Replies)
Discussion started by: BG_JrAdmin
6 Replies
3. Shell Programming and Scripting
I'm piping the results of a tcpdump into a shell script and want certain commands executed (specifically the firing of an SNMP alert) based on a grep for certain contents in the output of tcpdump.
For example, I have
#!/bin/bash
while read str; do
grep 'ttl 64' -q && sudo snmptrap -v 1... (2 Replies)
Discussion started by: paulobrad
2 Replies
4. Solaris
System: Sun M3000 and M4000
OS: Solaris 10 (fully up to date with latest patches)
iSCSI HBA: 2x QLE4060C (QLogic)
In each system are 2 QLE4060C iSCSI adapters.
I manage to set up both HBA's to connect to the LUNs on the SAN
However I don't manage to enable multi-pathing.
Made the... (4 Replies)
Discussion started by: sb008
4 Replies
5. Solaris
hi,
what are the steps to detect and configure a new attached lun in Solaris 10.
Is there any difference between cfgadm and luxadm command ?
rgds,
snjksh (5 Replies)
Discussion started by: snjksh
5 Replies
6. Linux
Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
echo "1" > /sys/class/fc_host/host<n>/issue_lip
and
echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies
7. Red Hat
need to do LUN masking at qlogic HBA level..at RHEL 5.x
I am using qla* module at part of the Unix kernel, it is not OEM drivers that come with the HBA card, so I can't use Sansurfer to do this..
Is there a way to do this at all ??
:wall: (0 Replies)
Discussion started by: ppchu99
0 Replies
8. Solaris
Hi All,
I'm using Solaris server, SunOS 5.10 Generic_144488-08 sun4u sparc SUNW, SPARC-Enterprise.
There is a newly created LUN of 250GB (EMC). I've scanned the system and able to see the new LUN.
For example:
103. emcpower19a <DGC-VRAID-0430 cyl 48638 alt 2 hd 256 sec 16>... (4 Replies)
Discussion started by: superHonda123
4 Replies
9. Shell Programming and Scripting
Hi,
GetName()
{
if
then
echo " Please enter the name: "
read Name
tempvar=0
while read line
do
if
then
tempvar=`expr $tempvar + 1`
echo $tempvar
... (10 Replies)
Discussion started by: rituparna_gupta
10 Replies
10. Solaris
How to get LUN WWN (i.e LUN mapped from a storage box say Symmetrix or clariion) in Solaris. fcinfo command does give the Target port wwn but what i'm looking for is the LUN WWN. Any help is appreciated. (2 Replies)
Discussion started by: Manish00712
2 Replies
LEARN ABOUT XFREE86
rgephy
RGEPHY(4) BSD Kernel Interfaces Manual RGEPHY(4)
NAME
rgephy -- RealTek RTL8168/8169/8110/8211 series 10/100/1000 Gigabit Ethernet PHY driver
SYNOPSIS
To compile all available PHY drivers into the kernel, place the following line in your kernel configuration file:
device miibus
Alternatively, to selectively compile this driver into the kernel, place the following lines in your kernel configuration file instead:
device mii
device rgephy
DESCRIPTION
The rgephy driver supports the RealTek RTL8168, RTL8169, RTL8110 and RTL8211 series integrated 10/100/1000 Gigabit Ethernet PHYs.
In order to get a list of media types and options supported by a specific instance of the rgephy driver, run ifconfig -m on the instance of
its parent MAC driver.
Additionally, the rgephy driver supports the following special media option:
flag0 When manually setting media type and options via ifconfig(8), the rgephy driver by default also triggers an autonegotiation advertis-
ing the selected media. This is done in order to work around hardware issues in certain scenarios. It is believed that this behavior
does not cause harm in general but in fact can have an adverse effect in edge cases. In order to manually set the media type and
options without also triggering an autonegotiation, the rgephy driver allows to turn this behavior off via the flag0 media option.
Note that this special media option will not show up in the output of ifconfig(8), even when set.
EXAMPLES
Manually set 100BASE-TX full-duplex without also triggering an autonegotiation:
ifconfig re0 media 100baseTX mediaopt full-duplex,flag0
SEE ALSO
intro(4), miibus(4), ifconfig(8)
BSD
January 16, 2011 BSD