Operating Systems AIX System can't boot up after power outage Post 302938060 by agent.kgb on Wednesday 11th of March 2015 02:54:14 PM
Old 03-11-2015
Quote:
Originally Posted by rbatte1
Engineering call, I would suggest.
9111-285 are Power5 Intellistations. They are out of support.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

boot fails after power faliure

Hi, i was installing solaris 8 on sunfire v250 and the power fails :mad: , now it does not boot from cd rom and get the next msg: ð Sun Fire V120 (UltraSPARC-IIe 648MHz), No Keyboard OpenBoot 4.0, 512 MB memory installed, Serial #56338483. Ethernet address 0:3:ba:5b:a8:33, Host ID: 835ba833. ... (1 Reply)
Discussion started by: agustincm
1 Replies

2. Solaris

Booting up problem after power outage

hi guys, i'm new so don't bite too hard. having a problem booting up a V210 running sol9 on after a power outage... an init5 was done but not a init0 before the power cut... so now when booting up it gives the ff: SC Alert: Host System has Reset Probing system devices Probing memory... (2 Replies)
Discussion started by: lungsta
2 Replies

3. SCO

file system not getting mounted in read write mode after system power failure

After System power get failed File system is not getting mounted in read- write mode (1 Reply)
Discussion started by: gtkpmbpl
1 Replies

4. AIX

AIX does not boot after power on

We have a RS6000, model B50, type 7046, where I installed AIX 4.3.3 But, if the power goes off, the operating system does not restart, and I have to go there and push the button to start AIX again. Is there any way this procedure to be avoided, this is, I want the AIX to start automatically... (9 Replies)
Discussion started by: sebastia.net
9 Replies

5. AIX

Role of sys admin during power outage in Data center

i am new to aix environment and all my servers are @ remote location just curious to know , what issues/tasks we will be facing when there is a power outage in a data centre, i heard outage's will be a challenging task for administrators.. any example of that sort will be a great help (2 Replies)
Discussion started by: rigin
2 Replies

6. Linux

Administrator responsibilities, in case of power outage?

Hi guys, I was wondering if you could share some of your knowledge, in the event of a power outage. Let presume you are on duty and you get a call at midnight because half of your cabinets have no power, air conditioning is down and you deal with a ton of 500 error messages on your boxes. ... (9 Replies)
Discussion started by: TECK
9 Replies

7. AIX

IBM Power Pseries Open Firmware boot / VIOS POWERVM VET CODE

Hello, I installed PowerVM IVM Virtual I/O on P-550 but later found out that the machine isn't activated for CoD VET code for virtualization. So when booted , it goes into OPEN Firmware I/O Hosting requires a hosting partition boot not permitted exit called > ok Panel shows > IO... (3 Replies)
Discussion started by: filosophizer
3 Replies

8. Solaris

Configure Power Settings on Boot

Hi all, this is my first question on this forum, so if it isn't in the correct location, please let me know where to post. We are using Solaris 8 and with the power setting enabled the monitor will not wake up. It can take anywhere from 5 to 30 minutes for the monitor to display. One of the... (3 Replies)
Discussion started by: Wrongway
3 Replies

9. AIX

Automatic Server bootup after power outage?

Hi everyone, We had a power outage few days ago, and I got the servers up and running but I was informed to look into, if there is a way to bring up the servers automatically/defaultly. I was told the windows admin has their server set up where the servers are up automatically if there is a... (11 Replies)
Discussion started by: Adnans2k
11 Replies

10. AIX

IBM Power 740 won't boot after firmware update

A team member installed the wrong version of License Code on a Power 740 system used in our Development environment. The system will no longer boot. Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
dxpower(8)						      System Manager's Manual							dxpower(8)

NAME
dxpower - controls energy saving features on systems that can be power managed SYNOPSIS
/usr/bin/X11/dxpower DESCRIPTION
The Power Manager application, dxpower, is used to maintain and manage the power management features on computers and peripherals that can be power managed. Power Manager lets you place monitors in three power saving modes: Standby, Suspend, or Off and lets you selectively spin down inactive disks to reduce power consumption. You also can specify when you want power management features to be active: always, never, or only at a specific time of day. Privileged (root) users have the capability to set system wide power management values. Non-privileged users set power management values on their monitors for the current log in session. The Power Manager application can be invoked from: The CDE Application Manager Application Group: System_Admin System Admin Subgroup: Dai- lyAdmin If you are not using CDE, start Power Manager from the command line: # /usr/bin/X11/dxpower For more information about how to use the Power Manager application, start the application and click on the Help button. An alternative to using the Power Manager application is to set and control power management attributes from the command line by using the sysconfig command. Refer to System Administration for more information about setting and controlling power management from the command line. SEE ALSO
Commands: sysconfig(8) System Administration dxpower(8)
All times are GMT -4. The time now is 01:04 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy