Sponsored Content
Operating Systems Solaris Cannot remove disk added to zpool Post 302933685 by LittleLebowski on Sunday 1st of February 2015 01:56:40 PM
Old 02-01-2015
Quote:
Originally Posted by bartus11
If adding more disks is possible, then you could create mirrored vdevs, by attaching mirror disks to c3t5000CCA012B3E751d0 and c3t5000CCA012B39541d0. See manual for zpool attach command.
Why not just wipe out the zpool mirror that I just added and mirror using those? Pretty much out of disks at this point.
 

10 More Discussions You Might Find Interesting

1. Solaris

Remove the exported zpool

I had a pool which was exported and due to some issues on my SAN i was never able to import it again. Can anyone tell me how can i destroy the exported pool to free up the LUN. I tried to create a new pool on the same pool but it gives me following error # zpool create emcpool4 emcpower0c... (0 Replies)
Discussion started by: fugitive
0 Replies

2. Solaris

Can't remove a LUN from a Zpool!

I am not seeing anyway to remove a LUN from a Zpool... Am I missing something? or do i have to destroy the zpool and recreate it? (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies

3. Red Hat

Partitioning newly added disk to Redhat

Hi Everyone, I have added new Virtual disk to OS. The main point is I need to bring this whole Disk into LVM control, is it necessary to partition the disk using fdisk command and assign partition type as '8e', or can I directly add that disk into LVM, by running pvcreate command with out... (2 Replies)
Discussion started by: bobby320
2 Replies

4. AIX

Remove the disk online

Hi I have one of the disk missing in my NIMVG. My doubt is can I remove this hdisk2 online ? few of the file systems seems to be spread over 7 PV's. that's why i'm worried. Can someone suggest if I can replace this disk online. Also how to check if there is some data present in hdisk2 alone... (2 Replies)
Discussion started by: newtoaixos
2 Replies

5. Solaris

Bad exchange descriptor : not able to remove files under zpool

Hi , One of my zone went down and when i booted it up i could see the pool in degraded state with some check sum errors . we have brought the pool online after scrubbing. But few files are showing this error Bad exchange descriptor Please let me know how to remove these files (2 Replies)
Discussion started by: chidori
2 Replies

6. Solaris

Add disk to zpool

Hi, Quick question. I have a data zpool that consists of 1 disk. pool: data state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM data ONLINE 0 0 0 c0t50002AC0014B06BEd0 ONLINE... (2 Replies)
Discussion started by: general_lee
2 Replies

7. AIX

LPAR cannot added disk

Dear All, I created a new partition through "Integrated Virtualization Manager" but there have an error when I added a new disk to the partition. The disk already created without any issue, Below error is to add the disk to the partition An error occured while modifying the assignments... (5 Replies)
Discussion started by: lckdanny
5 Replies

8. Solaris

Exporting zpool sitting on different disk partition

Hello, I need some help in recovering ZFS pool. Here is scenerio. There are two disks - c0t0d0 - This is good disk. I cloned it from other server and boot server from this disk. c0t1d0 - This is original disk of this server, having errors. I am able to mount it on /mnt. So that I can copy... (1 Reply)
Discussion started by: solaris_1977
1 Replies

9. Solaris

Replace zpool with another disk

issue, I had a zpool which was full pool_temp1 199G 197G 1.56G 99% ONLINE - pool_temp2 199G 196G 3.09G 98% ONLINE - as you can see, full so I replaced with a larger disk. zpool replace pool_temp1 c3t600144F0FF8BA036000058CC1DB80008d0s0... (2 Replies)
Discussion started by: rrodgers
2 Replies

10. Solaris

How to clear a removed single-disk pool from being listed by zpool import?

On an OmniOS server, I removed a single-disk pool I was using for testing. Now, when I run zpool import it will show it as FAULTED, since that single disk not available anymore. # zpool import pool: fido id: 7452075738474086658 state: FAULTED status: The pool was last... (11 Replies)
Discussion started by: priyadarshan
11 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), gvinum(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 03:08 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy