Old 01-11-2015
Dear Hicks ,

Thanks for the reply. Pl find the below outputs of the Server implemented Hardware raid. Kindly guide me , I have not done patching in these Hardware raid implemented Servers.

1. Uname -a :
Code:
SunOS  -03 5.10 Generic_142900-02 sun4v sparc SUNW,SPARC-Enterprise-T5220

2.
Code:
cat /etc/release
                      Solaris 10 10/09 s10s_u8wos_08a SPARC
           Copyright 2009 Sun Microsystems, Inc.  All Rights Reserved.
                        Use is subject to license terms.
                           Assembled 16 September 2009

3. df -h
Code:
# df -h
Filesystem             size   used  avail capacity  Mounted on
/dev/dsk/c1t0d0s0       14G   7.8G   6.5G    55%    /
/devices                 0K     0K     0K     0%    /devices
ctfs                     0K     0K     0K     0%    /system/contract
proc                     0K     0K     0K     0%    /proc
mnttab                   0K     0K     0K     0%    /etc/mnttab
swap                   7.4G   1.5M   7.4G     1%    /etc/svc/volatile
objfs                    0K     0K     0K     0%    /system/object
sharefs                  0K     0K     0K     0%    /etc/dfs/sharetab
/platform/SUNW,SPARC-Enterprise-T5220/lib/libc_psr/libc_psr_hwcap2.so.1
                        14G   7.8G   6.5G    55%    /platform/sun4v/lib/libc_psr.so.1
/platform/SUNW,SPARC-Enterprise-T5220/lib/sparcv9/libc_psr/libc_psr_hwcap2.so.1
                        14G   7.8G   6.5G    55%    /platform/sun4v/lib/sparcv9/libc_psr.so.1
fd                       0K     0K     0K     0%    /dev/fd
/dev/dsk/c1t0d0s3      4.8G   1.1G   3.6G    24%    /var
swap                    14G   6.9G   7.4G    49%    /tmp
swap                   7.4G    32K   7.4G     1%    /var/run
/dev/dsk/c1t0d0s4      4.8G   2.0G   2.7G    43%    /export
/dev/dsk/c1t0d0s5       35G    18G    16G    53%    /space

echo |format
root@  # echo |format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c1t0d0 <LSILOGIC-LogicalVolume-3000 cyl 65533 alt 2 hd 16 sec 136>
          /pci@0/pci@0/pci@2/scsi@0/sd@0,0
Specify disk (enter its number): Specify disk (enter its number):

#### raidctl -l
Controller: 1
        Volume:c1t0d0
        Disk: 0.0.0
        Disk: 0.1.0

Thanks and regards ,
Rj

Last edited by DukeNuke2; 01-11-2015 at 02:25 PM..
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

3. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Patching on Raid 0 Disk

Dear All , We need to do patching on one Solaris Server , where we have raid 0 configured. What is the process to patch a Server if RAID 0 (Concat/Stripe) is there. Below is the sample output. # metadb flags first blk block count a m pc luo 16 ... (1 Reply)
Discussion started by: jegaraman
1 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
disks(1M)						  System Administration Commands						 disks(1M)

NAME
disks - creates /dev entries for hard disks attached to the system SYNOPSIS
/usr/sbin/disks [-C] [-r rootdir] DESCRIPTION
devfsadm(1M) is now the preferred command for /dev and should be used instead of disks. disks creates symbolic links in the /dev/dsk and /dev/rdsk directories pointing to the actual disk device special files under the /devices directory tree. It performs the following steps: 1. disks searches the kernel device tree to see what hard disks are attached to the system. It notes the /devices pathnames for the slices on the drive and determines the physical component of the corresponding /dev/dsk or /dev/rdsk name. 2. The /dev/dsk and /dev/rdsk directories are checked for disk entries - that is, symbolic links with names of the form cN[tN]dNsN, or cN[tN]dNpN, where N represents a decimal number. cN is the logical controller number, an arbitrary number assigned by this program to designate a particular disk controller. The first controller found on the first occasion this program is run on a system, is assigned number 0. tN is the bus-address number of a subsidiary controller attached to a peripheral bus such as SCSI or IPI (the target number for SCSI, and the facility number for IPI controllers). dN is the number of the disk attached to the controller. sN is the slice number on the disk. pN is the FDISK partition number used by fdisk(1M). (x86 Only) 3. If only some of the disk entries are found in /dev/dsk for a disk that has been found under the /devices directory tree, disks creates the missing symbolic links. If none of the entries for a particular disk are found in /dev/dsk, disks checks to see if any entries exist for other disks attached to the same controller, and if so, creates new entries using the same controller number as used for other disks on the same controller. If no other /dev/dsk entries are found for slices of disks belonging to the same physical con- troller as the current disk, disks assigns the lowest-unused controller number and creates entries for the disk slices using this newly-assigned controller number. disks is run automatically each time a reconfiguration-boot is performed or when add_drv(1M) is executed. When invoking disks(1M) manually, first run drvconfig(1M) to ensure /devices is consistent with the current device configuration. Notice to Driver Writers disks considers all devices with a node type of DDI_NT_BLOCK, DDI_NT_BLOCK_CHAN, DDI_NT_CD, DDI_NT_BLOCK_WWN or DDI_NT_CD_CHAN to be disk devices. disks(1M) requires the minor name of disk devices obey the following format conventions. The minor name for block interfaces consists of a single lowercase ASCII character, a through u. The minor name for character (raw) inter- faces consists of a single lowercase ASCII character, a through u, followed by ,raw. disks translates a through p to s0 through s15, while it translates q through u to p0 through p4. SPARC drivers should only use the first 8 slices: a through h, while x86 drivers can use a through u, with q through u corresponding to fdisk(1M) partitions. q represents the entire disk, while r, s, t, and u represent up to 4 additional partitions. To prevent disks from attempting to automatically generate links for a device, drivers must specify a private node type and refrain from using a node type: DDI_NT_BLOCK, DDI_NT_BLOCK_CHAN, DDI_NT_CD, or DDI_NT_CD_CHAN when calling ddi_create_minor_node(9F). OPTIONS
The following options are supported: -C Causes disks to remove any invalid links after adding any new entries to /dev/dsk and /dev/rdsk. Invalid links are links which refer to non-existent disk nodes that have been removed, powered off, or are otherwise inaccessible. -r rootdir Causes disks to presume that the /dev/dsk, /dev/rdsk and /devices directory trees are found under rootdir, not directly under /. ERRORS
If disks finds entries of a particular logical controller linked to different physical controllers, it prints an error message and exits without making any changes to the /dev directory, since it cannot determine which of the two alternative logical-to-physical mappings is correct. The links should be manually corrected or removed before another reconfiguration-boot is performed. EXAMPLES
Example 1: Creating Block and Character Minor Devices The following example demonstrates creating the block and character minor devices from within the xkdisk driver's attach(9E) function. #include <sys/dkio.h> /* * Create the minor number by combining the instance number * with the slice number. */ #define MINOR_NUM(i, s) ((i) << 4 | (s)) int xkdiskattach(dev_info_t *dip, ddi_attach_cmd_t cmd) { int instance, slice; char name[8]; /* other stuff in attach... */ instance = ddi_get_instance(dip); for (slice = 0; slice < V_NUMPAR; slice++) { /* * create block device interface */ sprintf(name, "%c", slice + 'a'); ddi_create_minor_node(dip, name, S_IFBLK, MINOR_NUM(instance, slice), DDI_NT_BLOCK_CHAN, 0); /* * create the raw (character) device interface */ sprintf(name,"%c,raw", slice + 'a'); ddi_create_minor_node(dip, name, S_IFCHR, MINOR_NUM(instance, slice), DDI_NT_BLOCK_CHAN, 0); } } Installing the xkdisk disk driver on a Sun Fire 4800, with the driver controlling a SCSI disk (target 3 attached to an isp(7D) SCSI HBA) and performing a reconfiguration-boot (causing disks to be run) creates the following special files in /devices. # ls -l /devices/ssm@0,0/pci@18,700000/pci@1/SUNW,isptwo@4/ brw-r----- 1 root sys 32, 16 Aug 29 00:02 xkdisk@3,0:a crw-r----- 1 root sys 32, 16 Aug 29 00:02 xkdisk@3,0:a,raw brw-r----- 1 root sys 32, 17 Aug 29 00:02 xkdisk@3,0:b crw-r----- 1 root sys 32, 17 Aug 29 00:02 xkdisk@3,0:b,raw brw-r----- 1 root sys 32, 18 Aug 29 00:02 xkdisk@3,0:c crw-r----- 1 root sys 32, 18 Aug 29 00:02 xkdisk@3,0:c,raw brw-r----- 1 root sys 32, 19 Aug 29 00:02 xkdisk@3,0:d crw-r----- 1 root sys 32, 19 Aug 29 00:02 xkdisk@3,0:d,raw brw-r----- 1 root sys 32, 20 Aug 29 00:02 xkdisk@3,0:e crw-r----- 1 root sys 32, 20 Aug 29 00:02 xkdisk@3,0:e,raw brw-r----- 1 root sys 32, 21 Aug 29 00:02 xkdisk@3,0:f crw-r----- 1 root sys 32, 21 Aug 29 00:02 xkdisk@3,0:f,raw brw-r----- 1 root sys 32, 22 Aug 29 00:02 xkdisk@3,0:g crw-r----- 1 root sys 32, 22 Aug 29 00:02 xkdisk@3,0:g,raw brw-r----- 1 root sys 32, 23 Aug 29 00:02 xkdisk@3,0:h crw-r----- 1 root sys 32, 23 Aug 29 00:02 xkdisk@3,0:h,raw /dev/dsk will contain the disk entries to the block device nodes in /devices # ls -l /dev/dsk /dev/dsk/c0t3d0s0 -> ../../devices/[...]/xkdisk@3,0:a /dev/dsk/c0t3d0s1 -> ../../devices/[...]/xkdisk@3,0:b /dev/dsk/c0t3d0s2 -> ../../devices/[...]/xkdisk@3,0:c /dev/dsk/c0t3d0s3 -> ../../devices/[...]/xkdisk@3,0:d /dev/dsk/c0t3d0s4 -> ../../devices/[...]/xkdisk@3,0:e /dev/dsk/c0t3d0s5 -> ../../devices/[...]/xkdisk@3,0:f /dev/dsk/c0t3d0s6 -> ../../devices/[...]/xkdisk@3,0:g /dev/dsk/c0t3d0s7 -> ../../devices/[...]/xkdisk@3,0:h and /dev/rdsk will contain the disk entries for the character device nodes in /devices # ls -l /dev/rdsk /dev/rdsk/c0t3d0s0 -> ../../devices/[...]/xkdisk@3,0:a,raw /dev/rdsk/c0t3d0s1 -> ../../devices/[...]/xkdisk@3,0:b,raw /dev/rdsk/c0t3d0s2 -> ../../devices/[...]/xkdisk@3,0:c,raw /dev/rdsk/c0t3d0s3 -> ../../devices/[...]/xkdisk@3,0:d,raw /dev/rdsk/c0t3d0s4 -> ../../devices/[...]/xkdisk@3,0:e,raw /dev/rdsk/c0t3d0s5 -> ../../devices/[...]/xkdisk@3,0:f,raw /dev/rdsk/c0t3d0s6 -> ../../devices/[...]/xkdisk@3,0:g,raw /dev/rdsk/c0t3d0s7 -> ../../devices/[...]/xkdisk@3,0:h,raw FILES
/dev/dsk/* Disk entries (block device interface) /dev/rdsk/* Disk entries (character device interface) /devices/* Device special files (minor device nodes) ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ SEE ALSO
add_drv(1M), devfsadm(1M), fdisk(1M), attributes(5), isp(7D), devfs(7FS), dkio(7I), attach(9E), ddi_create_minor_node(9F) Writing Device Drivers BUGS
disks silently ignores malformed minor device names. SunOS 5.10 7 Nov 2002 disks(1M)
All times are GMT -4. The time now is 09:38 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy