10-15-2014
Yes,your understanding is correct.
However,just once this problem has come for faulty processor card and cable in the frame so for replacement it would take at least 4 hours I was curious if there is a way which would take less than 4 hrs may by migrating/mapping lpar in other frame so that we don't get into performance issues for loading one node completely during the time the hardware replacement would be carried out on the frame in which there is other node of cluster.
Because of licensing I think there is issue on increasing resources on other lpar
Best regards,
Vishal
10 More Discussions You Might Find Interesting
1. AIX
I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies
2. AIX
Hi,
I have 2 lpars on my AIX that needs to be started manually after each reboot.
Because the servers are storing the NFS and NIS info, other servers won't run correctly until they start up.
I found in IBM documentation the steps to make it automatic.
My question is, I want to know if... (2 Replies)
Discussion started by: rahzzbietel
2 Replies
3. AIX
I am planning for System P with 2 number of 2-core processor (4 core in total).
Can I make 3 LPARS with this processor configuration without the support of micropartitioning, that means with simple LPAR only. (3 Replies)
Discussion started by: pchangba
3 Replies
4. AIX
can i get a step b syep explanation in creating LPAR... i have searched for tutorials i couldn't find the right one.... (2 Replies)
Discussion started by: udtyuvaraj
2 Replies
5. AIX
I have created a new LPAR using IVM.
I activated the LPAR, and start the window terminal (java), it prompt me for the padmin password.
After keyin the password, it will shows BOOTP parameter.
I am just wondering how come it didnt go to screen where i can select to go into SMS menu to pick... (0 Replies)
Discussion started by: wingcross
0 Replies
6. AIX
Hi all,
I have the following configuration
2 ds3524 storage disk systems located over 2 locations
2 P720 server located over 2 locations
DS3524 are connected to san switch.
Each vio server has 1 fc adapter attached to a san switch.
per p720 server 2 virtual io servers. Vio 1 has 1 lun... (2 Replies)
Discussion started by: markiemark
2 Replies
7. AIX
Hi Folks,
I am a newbie in AIX.
Can someone please tell me how to do root mirroring in AIX LPAR which is created from mksysb image via HMC/NIM. ?
AIX 5.3/6.1
Let me know.
Thanks in advance (2 Replies)
Discussion started by: snchaudhari2
2 Replies
8. AIX
Hi Gurus,
Can a AIX server with 4 LPARs, each having it's own hostname on the same physical host. Is this possible?
Thanks,
S (2 Replies)
Discussion started by: svajhala
2 Replies
9. AIX
There can be configurations in IBM Server wherein a
standalone partition is created on some supported IBM Server
Or
A VIOS - VIOC LPARs created.
Now in both cases they are lpars. But if I want to differentiate b/w a standalone LPAR vs an VIOC LPAR how can I do..?
On a... (2 Replies)
Discussion started by: Manish00712
2 Replies
10. AIX
I'm New to AIX / VIOS
We're doing a FC switch cutover on an ibm device, connected via SAN.
How do I tell if one path to my remote disk is lost? (aix lvm)
How do I tell when my link is down on my HBA port?
Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin