Sorry for Interrupting,
Vishal,
As per my understanding to your post, I observe that your environment has 2 FRAMES, each with 1 LPAR and DB running on both lpars.
Your question is as your Frame1 keeps troubling , so want to migrate permanently the Lpar in Frame1 to Frame2, am I right?
If so, What if your trustful frame2 goes down.
10 More Discussions You Might Find Interesting
1. AIX
I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies
2. AIX
Hi,
I have 2 lpars on my AIX that needs to be started manually after each reboot.
Because the servers are storing the NFS and NIS info, other servers won't run correctly until they start up.
I found in IBM documentation the steps to make it automatic.
My question is, I want to know if... (2 Replies)
Discussion started by: rahzzbietel
2 Replies
3. AIX
I am planning for System P with 2 number of 2-core processor (4 core in total).
Can I make 3 LPARS with this processor configuration without the support of micropartitioning, that means with simple LPAR only. (3 Replies)
Discussion started by: pchangba
3 Replies
4. AIX
can i get a step b syep explanation in creating LPAR... i have searched for tutorials i couldn't find the right one.... (2 Replies)
Discussion started by: udtyuvaraj
2 Replies
5. AIX
I have created a new LPAR using IVM.
I activated the LPAR, and start the window terminal (java), it prompt me for the padmin password.
After keyin the password, it will shows BOOTP parameter.
I am just wondering how come it didnt go to screen where i can select to go into SMS menu to pick... (0 Replies)
Discussion started by: wingcross
0 Replies
6. AIX
Hi all,
I have the following configuration
2 ds3524 storage disk systems located over 2 locations
2 P720 server located over 2 locations
DS3524 are connected to san switch.
Each vio server has 1 fc adapter attached to a san switch.
per p720 server 2 virtual io servers. Vio 1 has 1 lun... (2 Replies)
Discussion started by: markiemark
2 Replies
7. AIX
Hi Folks,
I am a newbie in AIX.
Can someone please tell me how to do root mirroring in AIX LPAR which is created from mksysb image via HMC/NIM. ?
AIX 5.3/6.1
Let me know.
Thanks in advance (2 Replies)
Discussion started by: snchaudhari2
2 Replies
8. AIX
Hi Gurus,
Can a AIX server with 4 LPARs, each having it's own hostname on the same physical host. Is this possible?
Thanks,
S (2 Replies)
Discussion started by: svajhala
2 Replies
9. AIX
There can be configurations in IBM Server wherein a
standalone partition is created on some supported IBM Server
Or
A VIOS - VIOC LPARs created.
Now in both cases they are lpars. But if I want to differentiate b/w a standalone LPAR vs an VIOC LPAR how can I do..?
On a... (2 Replies)
Discussion started by: Manish00712
2 Replies
10. AIX
I'm New to AIX / VIOS
We're doing a FC switch cutover on an ibm device, connected via SAN.
How do I tell if one path to my remote disk is lost? (aix lvm)
How do I tell when my link is down on my HBA port?
Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies
stopped(7) Miscellaneous Information Manual stopped(7)
NAME
stopped - event signalling that a job has stopped
SYNOPSIS
stopped JOB=JOB INSTANCE=INSTANCE RESULT=RESULT [PROCESS=PROCESS] [EXIT_STATUS=STATUS] [EXIT_SIGNAL=SIGNAL] [ENV]...
DESCRIPTION
The stopped event is generated by the Upstart init(8) daemon when an instance of a job has stopped. The JOB environment variable contains
the job name, and the INSTANCE environment variable contains the instance name which will be empty for single-instance jobs.
If the job was stopped normally, the RESULT environment variable will be ok, otherwise if the job was stopped because it has failed it will
be failed.
When the job has failed, the process that failed will be given in the PROCESS environment variable. This may be pre-start, post-start,
main, pre-stop or post-stop; it may also be the special value respawn to indicate that the job was stopped because it hit the respawn
limit.
Finally in the case of a failed job, one of either EXIT_STATUS or EXIT_SIGNAL may be given to indicate the cause of the stop. Either
EXIT_STATUS will contain the exit status code of the process, or EXIT_SIGNAL will contain the name of the signal that the process received.
The normal exit job configuration stanza can be used to prevent particular exit status values or signals resulting in a failed job, see
init(5) for more information.
If neither EXIT_STATUS or EXIT_SIGNAL is given for a failed process, it is because the process failed to spawn (for example, file not
found). See the system logs for the error.
init(8) emits this event as an informational signal, services and tasks started or stopped by this event will do so in parallel with other
activity. It is typically combined with the starting(7) event by services when inserting themselves as a dependency.
Job configuration files may use the export stanza to export environment variables from their own environment into the stopped event. See
init(5) for more details.
EXAMPLE
A service that wishes to be running whenever another service would be running, started before and stopped after it, might use:
start on starting apache
stop on stopped apache
A task that must be run after another task or service has been stopped might use:
start on stopped postgresql
SEE ALSO
starting(7) started(7) stopping(7) init(5)
Upstart 2009-07-09 stopped(7)