Operating Systems Solaris Sun Fire V245 patching issue Post 302916890 by gull04 on Friday 12th of September 2014 11:27:16 AM
Old 09-12-2014
Hi,

You can try the following;

From the ok prompt "boot -F" or "boot -F failsafe" - if you are able to get the M/C up and running it looks like the FCA's need a firmware upgrade and they may not work on the upgraded version without it.

However if the box boots in failsafe mode you should have some more information on the diagnostic output. In which case you'll have to follow the advice.

Regards

Dave
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Sun Fire v1280 is crashing

I still haven't got an answer to this question... Excerpt from My SysAd Blog A colleague of mine is having a problem with a Sun Fire v1280 server crashing. He tried Googling for the error message in red but hasn't found anything yet. Your insights would be greatly appreciated. "cannot... (2 Replies)
Discussion started by: esofthub
2 Replies

2. UNIX for Dummies Questions & Answers

Sun Fire 280R

Hello all, I'm lost and can't figure this problem out. I have a Sun fire 280R running Solaris 8. Everything was working great. I have one drive in bay 1(not 0). But when I reboot the system it trys to open files in /dev/rdsk/c1t1d0s0. Should it have been opeing /dev/rdsk/c1t0d0s0, the... (4 Replies)
Discussion started by: larryase
4 Replies

3. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

4. Solaris

Sun Fire 280R Sun Solaris CRT/Monitor requirements

I am new to Sun. I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor? Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies

5. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

6. Solaris

Sun Fire 4800 is not powering-on

I switched on the power to the server. But, the server did not power on i.e., none of the 3 LEDs on the front panel is lighted. (Power supplies are showing only amber LEDs with "Ready to remove" sign). I tried to turn on the power supplies via System Controller menu (platform shell), but it... (6 Replies)
Discussion started by: solind
6 Replies

7. Solaris

Sun-Fire-V490 Printer Issue After Upgrade of Solaris

Hey Guys I am new here, dont know if any one can assist me with this issue. I have a Sun-Fire-V490 machine that was upgraded to version 9 and patched a few months back. Problem is a few network printers managed by the server is printing an extra page that comes out before and after every print... (0 Replies)
Discussion started by: mprogams
0 Replies

8. Hardware

SUN V245 Connecting To router Through Alom

Hello. I have a sun v245 and I have no hard drive for it yet but i would like to connect it to my home router by ethernet cable so I can use Alom remotely. Could someone please tell me how to set it up. Thank You (1 Reply)
Discussion started by: SunV245
1 Replies

9. Solaris

Sun fire x2270

Hello, I have purchaced an old SUn fire x2270 server . I wanted to make ILOM upgrade to the latest version of software : ILOM 3.0.9.18.a r126592 BIOS vers. 2.09 Server 2.2.3 (10-Aug-2018) Because my version is very outdated. But i can't download the updatebecause it's require... (4 Replies)
Discussion started by: LouisLakoute
4 Replies
UPSLUG2(8)						      System Manager's Manual							UPSLUG2(8)

NAME
upslug2 - utility to upgrade the firmware of a NSLU2 via the network SYNOPSIS
upslug2 [options] DESCRIPTION
upslug2 is a command line program intended to allow the upgrade the firmware of a Linksys NSLU2 (Network Storage Link for USB 2.0 Disk Drives) to new or different versions. When a NSLU2 in the local network is put in upgrade mode, upslug2 can connect to it and upload a new firmware. upslug2 will accept a full firmware image but it can also upgrade the flash from individual files holding the kernel, ramdisk and root filesystem. upslug2 provides status information during the upgrade process and verifies the written image after the upgrade. OPTIONS
-C, --Complete-reprogram Reprogram the complete flash, including the RedBoot boot loader and the SysConf partition holding configuration information. Using this option may result in the NSLU2 becoming permanently unusable! By default, upslug2 will not touch these two partitions since this allows flashing a new firmware if an uploaded firmware does not work. This is not possible if RedBoot itself is damaged. Use with caution. -d, --device The network device on the host machine connected to the network on which the NSLU2 is located. (Default: eth0). -e, --endian The endianness of the files to be uploaded. upslug2 will usually detected the endianness automatically but this option can be used to force byte swapping to occur. This option accepts three values, separated by comma: endianness of kernel, data and RedBoot FIS directory. Valid values are l (little endian), p (pdp endian) and b (big endian). (Default: ,b,b) -f, --from The MAC address of the host system. -h, --help Show summary of options. -i, --image The complete flash image to use. -j, --rootfs A root filesystem, usually of type jffs. -k, --kernel A compressed kernel zImage image. -n, --no-reboot Do not reboot after upgrade -p, --payload FIS directory payload. There are about 140 Kb in the last block (between the FIS dir and the trailer at the end) which can be used for data. -r, --ramdisk A compressed ramdisk image. -R, --ram-payload A ram paylod (replaced ramdisk). (FIXME: if it replaced the ramdisk, why cannot you just use the -r option? What's the difference) -t, --target The MAC address of the NSLU2 to upgrade. Without this option, upslug2 will only perform an upgrade if there is just one NSLU2 in upgrade mode. -U, --no-verify Do not verify the image, only upgrade. -v, --verify Do not write to flash, only verify the image. Options to specify firmware information The following options should be used when individual kernel, ramdisk and root filesystem files are specified rather than a complete firmware image. -E, --extra-version Extra version information, a 2 byte value. (Default: 0x90f7) -F, --firmware-version The firmware version, a 2 byte value. (Default: 0x2329) -P, --product-id The product ID, a 2 byte value. (Default: 1) -T, --protocol-id The protocol ID, a 2 byte value. (Default: 0) USING UPSLUG2 In order to use upslug2 the NSLU2 which is to be upgraded has to be put in upgrade mode: 1. Disconnect any disks and/or devices from the USB ports. 2. Power off the NSLU2 3. Press and hold the reset button (accessible through the small hole on the back just above the power input). 4. Press and release the power button to power on the NSLU2. 5. Wait for 10 seconds watching the ready/status LED. After 10 seconds it will change from amber to red. Immediately release the reset but- ton. 6. The NSLU2 ready/status LED will flash alternately red/green (there is a 1 second delay before the first green). The NSLU2 is now in upgrade mode. If you decide not to flash the image the NSLU2 can be rebooted by disconnecting the power. If the ready/status LED does not turn green after step four it will remain red for several seconds then flash amber. This happens if you do not release the reset button in time - pull the power, reconnect it and repeat from the second step. Once the NSLU2 is in upgrade mode it will remain in this state until either the power is connected or a new image has been flashed. If the flash fails the NSLU2 will (eventually) return to upgrade mode EXAMPLES
The most common use of upslug2 is the following: upslug2 --image NSLU2_V23R63.bin This specifies a complete firmware image which will be written to flash. Alternatively, kernel, ramdisk and root filesystem can be specified individually: upslug2 -k nslu2-zImage -r ramdisk -j root.jffs In this case, the options -E, -F, -P and -T should typically be specified as well. By default, upslug2 will search for the NSLU2 on the network on your eth0 network interface. If the network is on a different interface, you can easily specify it: upslug2 -d eth1 --image NSLU2_V23R63.bin If there are potentially more than one NSLU2 in your network which may be in upgrade mode, you can specify its MAC address: upslug2 -t 00:11:85:12:34:56 --image NSLU2_V23R63.bin SEE ALSO
slugimage(1) AUTHOR
John Bowler <jbowler@acm.org> January 2006 UPSLUG2(8)
All times are GMT -4. The time now is 01:02 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy