09-12-2014
Hi,
You can try the following;
From the ok prompt "boot -F" or "boot -F failsafe" - if you are able to get the M/C up and running it looks like the FCA's need a firmware upgrade and they may not work on the upgraded version without it.
However if the box boots in failsafe mode you should have some more information on the diagnostic output. In which case you'll have to follow the advice.
Regards
Dave
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
I still haven't got an answer to this question...
Excerpt from My SysAd Blog
A colleague of mine is having a problem with a Sun Fire v1280 server crashing. He tried Googling for the error message in red but hasn't found anything yet. Your insights would be greatly appreciated.
"cannot... (2 Replies)
Discussion started by: esofthub
2 Replies
2. UNIX for Dummies Questions & Answers
Hello all,
I'm lost and can't figure this problem out.
I have a Sun fire 280R running Solaris 8. Everything was working great. I have one drive in bay 1(not 0). But when I reboot the system it trys to open files in /dev/rdsk/c1t1d0s0. Should it have been opeing /dev/rdsk/c1t0d0s0, the... (4 Replies)
Discussion started by: larryase
4 Replies
3. Solaris
Hello,
I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies
4. Solaris
I am new to Sun.
I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor?
Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies
5. Solaris
Hi,
I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is
Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken.
Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
6. Solaris
I switched on the power to the server. But, the server did not power on i.e., none of the 3 LEDs on the front panel is lighted.
(Power supplies are showing only amber LEDs with "Ready to remove" sign).
I tried to turn on the power supplies via System Controller menu (platform shell), but it... (6 Replies)
Discussion started by: solind
6 Replies
7. Solaris
Hey Guys I am new here, dont know if any one can assist me with this issue.
I have a Sun-Fire-V490 machine that was upgraded to version 9 and patched a few months back.
Problem is a few network printers managed by the server is printing an extra page that comes out before and after every print... (0 Replies)
Discussion started by: mprogams
0 Replies
8. Hardware
Hello.
I have a sun v245 and I have no hard drive for it yet but i would like to connect it to my home router by ethernet cable so I can use Alom remotely. Could someone please tell me how to set it up.
Thank You (1 Reply)
Discussion started by: SunV245
1 Replies
9. Solaris
Hello,
I have purchaced an old SUn fire x2270 server .
I wanted to make ILOM upgrade to the latest version of software :
ILOM 3.0.9.18.a r126592
BIOS vers. 2.09
Server 2.2.3
(10-Aug-2018)
Because my version is very outdated.
But i can't download the updatebecause it's require... (4 Replies)
Discussion started by: LouisLakoute
4 Replies
LEARN ABOUT OPENSOLARIS
device_remap
device_remap(1M) System Administration Commands device_remap(1M)
NAME
device_remap - administer the Solaris I/O remapping feature
SYNOPSIS
/usr/platform/sun4v/sbin/device_remap [-v | -R dir]
DESCRIPTION
Certain multi-node sun4v platforms, such as T5440 and T5240 servers, have an integrated PCI topology that cause the I/O device paths to
change in a CPU node failover condition. The device remapping script, device_remap, remaps the device paths in /etc/path_to_inst file and
the symlinks under /dev to match the hardware.
OPTIONS
The following options are supported:
-v
Displays the /etc/path_to_inst and /dev symlink changes.
-R dir
Perform remapping on the /etc/path_to_inst and /etc/path_to_inst files in the root image at dir.
USAGE
The primary function of device_remap is to remap the device paths in the /etc/path_to_inst file and the symlinks under /dev in a CPU node
failover condition to match the hardware.
After adding CPU node(s) or removing CPU node(s), boot the system to the OBP prompt and use the following procedure:
1. Boot either the failsafe miniroot using: boot -F failsafe , or an install miniroot using boot net -s or similar command.
2. Mount the root disk as /mnt.
3. Change directory to the mounted root disk:
# cd /mnt
4. Run device_remap script:
# /mnt/usr/platform/sun4v/sbin/device_remap
5. Boot the system from disk.
All the error messages are self-explanatory, except for the error message "missing ioaliases node" which means the firmware on the system
does not support device remapping.
EXAMPLES
Example 1 Displaying Changes Following Failover
The following command displays the path_to_inst and /dev changes following a CPU node failover.
# device_remap -v
Example 2 Changing Directory Prior to Any Changes
The following command changes the directory on which the boot image is mounted prior to making any changes.
# device_remap -R /newroot
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWkvm.v |
+-----------------------------+-----------------------------+
|Interface Stability |Unstable |
+-----------------------------+-----------------------------+
SEE ALSO
boot(1M), attributes(5)