Special Forums IP Networking What RJ11 Cables Should I Use? Post 302916730 by Corona688 on Thursday 11th of September 2014 02:34:43 PM
Old 09-11-2014
The middle two conductors are the usual pair your telephone uses. The rest would be used to carry other telephone lines if you had more.

So, just about anything should work if you only care about the first telephone line.
This User Gave Thanks to Corona688 For This Post:
 

7 More Discussions You Might Find Interesting

1. Solaris

Scsi cables - which ones?

Is there any specific scsi cables that you need to get when connecting a tape drive or external storage or does one type of cable fit all? ie. I can buy the following: HD68 to HD68 with Ferrites supports S-E Ultra/Wide transfer rates. But will this work for tape drives and storage? I... (1 Reply)
Discussion started by: frustrated1
1 Replies

2. IP Networking

fc cables

hi friends, we are using fc cables and fc switches,u might be aware of the cost factor of it so just wanted to know that Why do we need FC switches and fiber-optic cables? Is it not possible to use, say, twisted-pair copper cables instead of fiber-optic cables, and achieve almost comparable... (3 Replies)
Discussion started by: mxms755
3 Replies

3. Solaris

pinout DB9 to RJ11 of T3 Array Disk?

Hello friends, i have a problem with the pinout of T3 Array Disk cuz i don't know to build this serial cable :( please anybody help me! (1 Reply)
Discussion started by: nikoxve
1 Replies

4. Solaris

1 or 2 Fiber cables?

Hi Community, I'm working on Solaris 10 installation with 1 Server V490 and 1 StoredgeTek 3510 (Standalone configuration). I'd connect the Server to the Storedge with a fiber cable but I' m in doubt becouse I don't know if using 1 or 2 fiber cable. Could you provide me any solution? ... (2 Replies)
Discussion started by: Sunb3
2 Replies

5. Solaris

SUNFIRE V240 procedure to shutdown with safety in order to replace power cables

Question: Which commands to use to shutdown with safety the server; (2 Replies)
Discussion started by: doudou2012
2 Replies

6. Hardware

Flat cables vs normal circular cables

Do flat cables have any advantage over normal circular cables? I was looking at this. 6ft 2M Flat USB Sync Data Cable Charger Cord for iPhone4 4S 3G iPad1 2 3 Orange | eBay (2 Replies)
Discussion started by: cokedude
2 Replies

7. War Stories

Following Cables for Fun!

Hi Folks, I came accross this picture taken a number of years ago now, I just thought I'd share it with you guys. We were in the process of removing equipment from the Data Centre and had followed the cable through to this area, where one of the old patch areas had been. When we lifted the... (2 Replies)
Discussion started by: gull04
2 Replies
ct(1C)							      Communication Commands							    ct(1C)

NAME
ct - spawn login to a remote terminal SYNOPSIS
ct [options] telno... DESCRIPTION
The ct utility dials the telephone number of a modem that is attached to a terminal and spawns a login process to that terminal. The telno is a telephone number, with equal signs for secondary dial tones and minus signs for delays at appropriate places. (The set of legal char- acters for telno is 0 through 9, -, =, *, and #. The maximum length telno is 31 characters). If more than one telephone number is speci- fied, ct will try each in succession until one answers; this is useful for specifying alternate dialing paths. ct will try each line listed in the file /etc/uucp/Devices until it finds an available line with appropriate attributes, or runs out of entries. After the user on the destination terminal logs out, there are two things that could occur depending on what type of port monitor is moni- toring the port. In the case of no port monitor, ct prompts: Reconnect? If the response begins with the letter n, the line will be dropped; otherwise, ttymon will be started again and the login: prompt will be printed. In the second case, where a port monitor is monitoring the port, the port monitor reissues the login: prompt. The user should log out properly before disconnecting. OPTIONS
The following options are supported: -h Normally, ct will hang up the current line so that it can be used to answer the incoming call. The -h option will prevent this action. The -h option will also wait for the termination of the specified ct process before returning control to the user's terminal. -sspeed The data rate may be set with the -s option. speed is expressed in baud rates. The default baud rate is 1200. -v If the -v (verbose) option is used, ct will send a running narrative to the standard error output stream. -wn If there are no free lines ct will ask if it should wait, and for how many minutes, before it gives up. ct will continue to try to open the dialers at one-minute intervals until the specified limit is exceeded. This dialogue may be overridden by specifying the -wn option. n is the maximum number of minutes that ct is to wait for a line. -xn This option is used for debugging; it produces a detailed output of the program execution on stderr. n is a single number between 0 and 9. As n increases to 9, more detailed debugging information is given. FILES
/etc/uucp/Devices /var/adm/ctlog ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWbnuu | +-----------------------------+-----------------------------+ SEE ALSO
cu(1C), login(1), uucp(1C), ttymon(1M), attributes(5) NOTES
The ct program will not work with a DATAKIT Multiplex interface. For a shared port, one used for both dial-in and dial-out, the ttymon program running on the line must have the -r and -b options specified (see ttymon(1M)). SunOS 5.10 14 Sep 1992 ct(1C)
All times are GMT -4. The time now is 11:33 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy