Hi,
I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7).
I extend my vg vg000 (on the partition) and add the 2 hdisks.
I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Hello guys,
It would be so nice of you if someone can provide me with these informations.
1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
I have a DUAL VIO ( IBM Virtual I/O ) setup on p 570.
Two Vio server ( VIOS ) and many LPAR clients.
VIO ( latest version + service pack + applied the fix ) and AIX 6.1 ML2
When both VIOs are running, and if I turn on a Client LPAR, the LPAR hangs at LED 25b3 for more than 1 hour then it... (2 Replies)
Hello,
I have created mapping of 2 virtual adapters for Lpars using following command:
mkvdev -vdev ipanalyzerlv1 -vadapter vhost11
mkvdev -vdev ipanalyzerlv -vadapter vhost13
The above two commands were succesfull
but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Hi All,
Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great.
... (5 Replies)
I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518
Reference Code Selection
0518 (Time stamp: 12/18/12 12:10:20 AM UTC)
Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC)
AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Hi,
Just joined to new company with one Power 720 Express (8202-E4C) server and have no much experience with IBM systems.
I am trying to move everything I mentioned to different subnet as required by customer contract (currently sitting on same subnet as company lan). Access to this subnet will... (8 Replies)
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Hello,
In my environment, I have 2 VIOS. There is 1 lpar uses the first VIOS. Now we would like to move it to second VIOS.
My question is, can we migrate the virtual FC on the lpar to second VIOS?
If not, we have to create new virtual FC on second VIOS and map it to the lpar. This also... (3 Replies)
Discussion started by: Phat
3 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)