Sponsored Content
Operating Systems Solaris How to increase the e1000g0 interface speed in Solaris? Post 302912367 by achenle on Thursday 7th of August 2014 03:49:05 PM
Old 08-07-2014
Quote:
Originally Posted by junior-helper
Hello gsrungav,
this is my humble approach (assuming you are allowed to shortly interrupt the g1 link): why don't you systematically troubleshoot that issue?

I'd do/check the following:

1. Is auto-negotiation active on g1? If yes, turn it on on g0 too.

2. What happens if you switch the network cables (from g1 to g0 and from g0 to g1).
Does g0 become 1000 Mbps? Does g1 become 100 Mbps only?
If both assumptions are true, then plug both cables back as it was before.
Now you can exclude the problem on the server side!

Start troubleshooting on the switch side, e.g. compare the configuration of the switch ports, where the g0 and g1 network cables are plugged in. It's possible, that the switch port, where the cable from g0 is plugged in, is configured for 100 Mbps only.

Hope this helps.
Exactly. There's a physical problem with the link that won't autonegotiate. If you're lucky, there's a good chance someone disabled autonegotiation on the switch side and pinned that switch port to 100fdx.

Again: disabling autonegotiation is bad. If a link won't autonegotiate the highest speed it's supposed to, SOMETHING IS WRONG. If a car gets a flat tire and doesn't handle well, you don't ignore it and just force it to continue going 120 kph/90 mph. You fix the flat.
This User Gave Thanks to achenle For This Post:
 

10 More Discussions You Might Find Interesting

1. Post Here to Contact Site Administrators and Moderators

Anybody Notice a Speed Increase?

Hi. I moved this site to a T3 facility and wanted to know if any of the long time users noticed a performance improvement? Thanks, Neo. (5 Replies)
Discussion started by: Neo
5 Replies

2. Solaris

how to force e1000g0 interface in solaris 10

Hi all, I encounter some problem with my e1000g interface running on sol 10. I can't permanently change the auto-nego to disable, if i use ndd commands, it will only stay until the next reboot. But i can't change the link speed either is set to /etc/init.d/nddconfig or using ndd commands. ... (1 Reply)
Discussion started by: mailbox80
1 Replies

3. Cybersecurity

how to increase the speed of sftp

hi , i have to tranfer some 12 - 13 gb of files from one server to anothier presently i m using the SFTP but it is taking to much time to trafer the files is there any way to use increase the efficiency of SFTP. i cant use the FTP (4 Replies)
Discussion started by: narang.mohit
4 Replies

4. Solaris

Command line Interface or GUI Interface not shown on solaris

Dear all, I am a newbie in solaris and I need your advice. I have a Solaris version 5.9 installed on Sunfire V240. I am able to ssh the machine from putty remotely. My problem is that I cannot see the display from KVM switch I have connected to it. I need also to be able to see the GUI... (2 Replies)
Discussion started by: mbouster
2 Replies

5. Solaris

hba speed Solaris 9

Hello, In Solaris 10 I can use fcinfo to find what speed the hba ports are running at, am I able to find this out using Solaris 9? I have tried a few variations on luxadm but cant find anything relevant. Thanks. (1 Reply)
Discussion started by: Actuator
1 Replies

6. Red Hat

Increase speed in linux server

Hi, Will removing space from the server increases the speed/performance. how are they related? please explain the relationship. thanks in advance regards, Pradeep (2 Replies)
Discussion started by: pradebban
2 Replies

7. Solaris

Solaris SPARC speed issue

Hello helpful Unix gurus! First, I appreciate any help I can get. I have a product that we have ported (for years now) on Solaris SPARC 7.x OS from 1998 (or around that time I guess) that is compiled to a 32 executable. It has run (with various modifications over the years) on any Solaris... (10 Replies)
Discussion started by: Pug
10 Replies

8. UNIX for Advanced & Expert Users

How to increase executions speed of loops.?

(2 Replies)
Discussion started by: Venkatesh1
2 Replies

9. Solaris

Interface e1000g0 not showing in running state

Hello all, I have a sun server SunOS PNR1RAD01 5.10 Generic_144488-09 sun4v sparc SUNW,Netra-T5220 where i have an interface e100g0. This was earlier in running state but now this doesnt show running state. I tried to reset the interface, checked the cable but it did not help. Can nyone pls... (10 Replies)
Discussion started by: rajjat2
10 Replies

10. AIX

AIX 4.2 increase ethernet speed

Hello. I have a server RS/6000 with AIX 4.2. The server have a network card with 10/100mbps speed, but for some reason, the ethernet only runs at 10Mbps, it doesn,t matter if I put the net cable on a 100Mbps switch, it keeps running at 10Mbps speed.... I know how to view/change ethernet speed... (1 Reply)
Discussion started by: little_ball
1 Replies
afe(7D) 							      Devices								   afe(7D)

NAME
afe - ADMtek Fast Ethernet device driver SYNOPSIS
/dev/afe DESCRIPTION
The afe driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on ADMtek (now Infineon) Centaur and Comet Fast Ethernet controllers. APPLICATION PROGRAMMING INTERFACE
The afe driver can be used as either a "style 1" or a "style 2" Data Link Service Provider. Physical points of attachment (PPAs) are inter- preted as the instance number of the afe controller as assigned by the Solaris operating environment. The relevant fields returned as part of a DL_INFO_ACK response are: o Maximum SDU is 1500. o Minimum SDU is 0. o The dlsap address length is 8. o MAC type is DL_ETHER. o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP. o Service mode is DL_CLDLS. o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff). If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are bound to SAP zero (the 802.3 SAP). PROPERTIES
The following properties may be configured using either ndd(1M) or the afe.conf configuration file as described by driver.conf(4): adv_autoneg_cap Enables (default) or disables IEEE 802.3u auto-negotiation of link speed and duplex settings. If enabled, the device negotiates among the supported (and configured, see below) link options with the link partner. If disabled, at least one of the link options below must be specified. The driver selects the first enabled link option according to the IEEE 802.3u specified preferences. adv_100T4_cap Enables the 100 BaseT4 link option. (Note that most hardware does not support this unusual link style. Also, this uses two pairs of wires for data, rather than one.) adv_100fdx_cap Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern equipment supports this mode.) adv_100hdx_cap Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.) adv_10fdx_cap Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps switch.) adv_10hdx_cap Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when the link partner is a 10 Mbps hub or is an older network card.) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SPARC, x86 | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ FILES
/dev/afe Special character device. /kernel/drv/afe 32-bit driver binary (x86). /kernel/drv/amd64/afe 64-bit driver binary (x86). /kernel/drv/sparcv9/afe 64-bit driver binary (SPARC). /kernel/drv/afe.conf Configuration file. SEE ALSO
ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P) IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002 SunOS 5.11 1 Apr 2007 afe(7D)
All times are GMT -4. The time now is 07:04 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy