Sponsored Content
Operating Systems AIX San disk appearing double in old AIX Post 302912176 by Tharsan on Wednesday 6th of August 2014 11:28:32 AM
Old 08-06-2014
DB San disk appearing double in old AIX

Hi guys, Smilie

I'm a studient in IT field (AIX)

I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00)

I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN

Code:
root@localhost # lscfg | grep hdisk
+ hdisk7           U787F.001.DPM35ZF-P1-C1-T2-W202400A0B868BF73-L0  fcparray Disk Array Device
+ hdisk8           U787F.001.DPM35ZF-P1-C1-T1-W202300A0B868BF73-L0  fcparray Disk Array Device

My senior told me there is a method for have an MPIO like.

Any one know how i can to that Smilie

Thanks for your help, and sorry for my english (from FRANCE) Smilie
 

10 More Discussions You Might Find Interesting

1. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

2. AIX

hard disk and san

Hello everyone I got several aix boxes with aix 5.3 I got a ibm san ds4500 My question is How can I do a match between my disks on aix and the san? I try to do a match with the LUN but for example. In my san I got several 1 LUN and on one of my aix box I got this If I type lscfg... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies

3. AIX

AIX 5.2/5.3 - rootvg on SAN disk - pros and cons

We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies

4. Solaris

SAN disk failure

hi all, have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ?? thanks in advance. (3 Replies)
Discussion started by: cesarNZ
3 Replies

5. Filesystems, Disks and Memory

SAN Disk w/o Cluster

Scenario: I've got 2 M5000's connected to a 9985 SAN storage array. I have configured the SAN disks with stmsboot, format and newfs. I can access the same SAN space from both systems. I have created files from both systems on the SAN space. Question: Why can't I see the file created... (3 Replies)
Discussion started by: bluescreen
3 Replies

6. UNIX for Dummies Questions & Answers

SAN and Disk I/O ... do we care?

Hi all, My main function is as a DBA. Another person manages the server and the SAN. I just want to know if I should be worried about high disk I/O or is it irrelevant as the I/O "load balancing" will be "taken care" of by the SAN? For example, I have hdisk1-5 and I can see that there are... (2 Replies)
Discussion started by: newbie_01
2 Replies

7. Solaris

I/O Error on SAN Disk

Hi, I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk. I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error. ... (6 Replies)
Discussion started by: Mack1982
6 Replies

8. AIX

SAN Disk Appearing double in AIX

Hello Folks, I have directly connected my IBM Pseries AIX machine to SAN Storage I have a dual port Fibre Channel Adapter Connected both fiber ports to SAN Box IBM DS4500 Controller A & Controller B Using IBM DS storage manager client 10 -- created one logical disk and assigned to a... (18 Replies)
Discussion started by: filosophizer
18 Replies

9. AIX

SAN DISK raid level in AIX

Hello All, Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ? Am having AIX 6.1 and EMC clarion 5.5. Regards, Gowtham.G (3 Replies)
Discussion started by: gowthamakanthan
3 Replies

10. UNIX for Beginners Questions & Answers

SAN vs. Local disk.

I am in the market looking to purchase a new E950 server and I am trying to decide between using local SSD drives or SSD based SAN. The application that will be running on this server is read-intensive so I am looking for the most optimal configuration to support this application. There are no... (2 Replies)
Discussion started by: ikx
2 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 09:38 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy