Sponsored Content
Special Forums Hardware Sunfire x4600 M2 NIC replacement Post 302908491 by Rockyc3400 on Tuesday 8th of July 2014 08:57:59 AM
Old 07-08-2014
Sunfire x4600 M2 NIC replacement

Hi All,

I am having an Sun fire X4600 M2 server where one of the interfaces is down.
I had requested for the replacement but had a bit problem in identifying the port.
As per the server service module, there are 4 NIC ports and one port is not flashing (e1000g0) but as per server, the port e1000g0 is fine but e1000g2 is down.

Also as per service manual, there are only for ports for this server but in the server output, i have 6 interfaces.


Code:
e1000g0         link: up        speed: 1000  Mbps       duplex: full
e1000g1         link: up        speed: 1000  Mbps       duplex: full
e1000g2         link: down      speed: 0     Mbps       duplex: half
e1000g3         link: up        speed: 1000  Mbps       duplex: full
e1000g4         link: up        speed: 1000  Mbps       duplex: full
e1000g5         link: up        speed: 1000  Mbps       duplex: full

e1000g0: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
e1000g0:1: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER> mtu 1500 index 2
e1000g1: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,PRIVATE,IPv4> mtu 1500 index 7
e1000g2: flags=xxxxxxx<UP,BROADCAST,MULTICAST,DEPRECATED,IPv4,NOFAILOVER,FAILED> mtu 1500 index 3
e1000g3: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,PRIVATE,IPv4> mtu 1500 index 6
e1000g4: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 4
e1000g4:1: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER> mtu 1500 index 4
e1000g4:2: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4> mtu 1500 index 4
e1000g5: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4,NOFAILOVER> mtu 1500 index 5
e1000g5:1: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4> mtu 1500 index 5
e1000g5:2: flags=xxxxxxx<UP,BROADCAST,RUNNING,MULTICAST,DEPRECATED,IPv4> mtu 1500 index 5.

Could you please help me in understanding this and how to proceed further with this to replace the NIC cable.

Regards,
Rocky

Last edited by DukeNuke2; 07-08-2014 at 10:15 AM..
 

9 More Discussions You Might Find Interesting

1. Solaris

console for x4600

Hi, I ;ve a SUN x4600 running solaris 10. I want to connect to the system remotely form console like we can connect to sparc sc or alom .. (9 Replies)
Discussion started by: fugitive
9 Replies

2. Solaris

x4600 iLOM issue

I need to configure the iLOM for x4600 server. before I can set the IP details and commit, I need to set network state should be enabled. However my firmware is already the latest and I need not upgrade. I am not able to set the /SP/network state to enable. pls assist. i BELIEVE the bug was fixed... (5 Replies)
Discussion started by: incredible
5 Replies

3. Solaris

x86 Solaris 10 nic driver added but not attached. NIC is not detected.

I couldn't install my nic in solaris 10. I compiled and added the driver but failed to attach the driver and ifconfig output shows only loopback dev. Please see the following output and tell me whether my nic has been detected and why the driver failed to attach? My nic is detected in linux... (0 Replies)
Discussion started by: vectrum
0 Replies

4. Solaris

Sunfire X4600 Errors on Bootup

Hi Folks, Has anyone seen these errors on bootup. Mar 15 12:22:30 svc.startd: svc:/system/device/local:default: Method "/lib/svc/method/devices-local" failed due to signal SEGV.ht (c) 1983, 2010, Oracle and/or its affiliates. All rights reserved. Configuring devices. ... (1 Reply)
Discussion started by: ESSTEAM
1 Replies

5. IP Networking

squid proxy: one NIC for inbound & one NIC for outbound?

I am new in squid proxy. My question is how to (and if it's necessary) to set one NIC for inbound traffic (http requests) and one NIC for outbound traffic (http answers)? Thank you in advance! (4 Replies)
Discussion started by: aixlover
4 Replies

6. Red Hat

I want to tune NIC's rps, rfs and xps value. which NIC device should I modify.

Dear All I want tune my NIC's rps, rfs and xps value. In my system I have two NIC (eth0, eth1) and I have a bond0 ( eth0, eth1). Here is the question? Which device should I modify ? eth0 and eth1? or just modify bond0 or modify all device (eth0, eth1, bond0) Any advice is welcome.... (0 Replies)
Discussion started by: nnnnnnine
0 Replies

7. Solaris

SunFire V240 CPU Heat Sink Replacement

I got a replacement Heatsink and Fan unit, but the OEM unit has the SUN Thermal Interface Material (TIM) already on the heatsink matting surface. Because mine is used it does not have the TIM. Also there are 2 different TIM material SUN used based on the Processor (1-1.28GHz uses a glue backed... (1 Reply)
Discussion started by: danneskjold0809
1 Replies

8. Hardware

Sun X4600 M2 enable Hyperthreading

Booting and checking BIOS there is no option to enable-disable hyperthreading. I have 8 Dual-Core AMD Opteron(tm) Processor 8220 and I see 16 cores. Enable hyperthreading I should have 32 cores. I have red hat 5.4 installed. Anyone know how can enable hypethreading ? I have last BIOS/Firmware... (2 Replies)
Discussion started by: laxtnog
2 Replies

9. Linux

Add two different subnet public IPs to single NIC or two different NIC on same box

Hello Admins, My ask is how can I add two different subnet IPs to same box with two different gateways? The issue is I can connect to the box when I am on ethernet LAN, but I am not able to connect to the same IP when I am on wifi. The server is RHEL 7 VM on vmware. How can I get connected... (4 Replies)
Discussion started by: snchaudhari2
4 Replies
afe(7D) 							      Devices								   afe(7D)

NAME
afe - ADMtek Fast Ethernet device driver SYNOPSIS
/dev/afe DESCRIPTION
The afe driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on ADMtek (now Infineon) Centaur and Comet Fast Ethernet controllers. APPLICATION PROGRAMMING INTERFACE
The afe driver can be used as either a "style 1" or a "style 2" Data Link Service Provider. Physical points of attachment (PPAs) are inter- preted as the instance number of the afe controller as assigned by the Solaris operating environment. The relevant fields returned as part of a DL_INFO_ACK response are: o Maximum SDU is 1500. o Minimum SDU is 0. o The dlsap address length is 8. o MAC type is DL_ETHER. o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP. o Service mode is DL_CLDLS. o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff). If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are bound to SAP zero (the 802.3 SAP). PROPERTIES
The following properties may be configured using either ndd(1M) or the afe.conf configuration file as described by driver.conf(4): adv_autoneg_cap Enables (default) or disables IEEE 802.3u auto-negotiation of link speed and duplex settings. If enabled, the device negotiates among the supported (and configured, see below) link options with the link partner. If disabled, at least one of the link options below must be specified. The driver selects the first enabled link option according to the IEEE 802.3u specified preferences. adv_100T4_cap Enables the 100 BaseT4 link option. (Note that most hardware does not support this unusual link style. Also, this uses two pairs of wires for data, rather than one.) adv_100fdx_cap Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern equipment supports this mode.) adv_100hdx_cap Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.) adv_10fdx_cap Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps switch.) adv_10hdx_cap Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when the link partner is a 10 Mbps hub or is an older network card.) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SPARC, x86 | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ FILES
/dev/afe Special character device. /kernel/drv/afe 32-bit driver binary (x86). /kernel/drv/amd64/afe 64-bit driver binary (x86). /kernel/drv/sparcv9/afe 64-bit driver binary (SPARC). /kernel/drv/afe.conf Configuration file. SEE ALSO
ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P) IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002 SunOS 5.11 1 Apr 2007 afe(7D)
All times are GMT -4. The time now is 06:50 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy