05-28-2014
What kind of instrumentation? Just dealing with this building's solar instrumentation I've needed to combine RS-232, RS-485, USB, I2C, and ethernet. If you're lucky enough to stick with one manufacturer I suppose it's the same protocol all the time.
You could set up another computer to send it to the "usb server" I suppose, but that seems like overkill. It could be possible to run your application on the same machine. Is this application willing to read from a FIFO or file?
8 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
We are trying to Establish Network using Linux.Now we are facing the problem in configring Ethernet.In out network we are giving eth0 in server and activating it at the boot time,so it is activating as it is but when we define the Ethernet of node on server and allowing it to activate at boot time... (5 Replies)
Discussion started by: at_renai2001
5 Replies
2. Solaris
I have a Quad Ethernet card in a 220R. 2 ports activated. Each has its own hostname file and both hostnames are in the hosts file. I want both ports to have the same IP address so we can use the 2nd port in case we lose communication on the port. On bootup, the box gives me:
SIOCSLIFFLAGS:... (5 Replies)
Discussion started by: hshapiro
5 Replies
3. AIX
Hello everyone
I have a problem with one server, has Aix 5.3 in the errpt has this message
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
F3931284 0105133009 I H ent0 ETHERNET NETWORK RECOVERY MODE
EC0BCCD4 0105133009 T H ent0 ETHERNET DOWN
F3931284 ... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies
4. Solaris
I have a new Sun 440 and I am trying to configure it. Non of the Ethernet ports are enabled; when I issue "ifconfig -a" it returns nothing. Is there a way to know the available port name (e.g. ce, bge, etc.) by running a command or so ? (4 Replies)
Discussion started by: StarSol
4 Replies
5. Solaris
my solris box network is unreachable how to solve this
ipaddress assiagning and entry in vi /etc/host
how to solve network is unreachable (2 Replies)
Discussion started by: tirupathi
2 Replies
6. Solaris
I had installed soalris 10 on my dell vostro 1400.It had installed succefully.
If i type ifconfig -a it is showing only my loop back adpater.
So how to tell me how to mount my usb drive and how to configure
my lan ethernet card,My lan ethernet card is Broadcom.
Tell me step... (1 Reply)
Discussion started by: testerindia25
1 Replies
7. UNIX for Dummies Questions & Answers
Is there an easy way to setup a cross-over cable (USB-USB) between a linux box and a windows PC? My 2 machines are next to each other but I really do not want to keep transfering my files using my USB drive.
Thanks! (4 Replies)
Discussion started by: Xterra
4 Replies
8. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
LEARN ABOUT PLAN9
s390_runtime_instr
S390_RUNTIME_INSTR(2) System Calls Manual S390_RUNTIME_INSTR(2)
NAME
s390_runtime_instr - enable/disable s390 CPU run-time instrumentation
SYNOPSIS
#include <asm/runtime_instr.h>
int s390_runtime_instr(int command, int signum);
DESCRIPTION
The s390_runtime_instr() system call starts or stops CPU run-time instrumentation for the calling thread.
The command argument controls whether run-time instrumentation is started (S390_RUNTIME_INSTR_START, 1) or stopped (S390_RUN-
TIME_INSTR_STOP, 2) for the calling thread.
The signum argument specifies the number of a real-time signal. The real-time signal is sent to the thread if the run-time instrumentation
buffer is full or if the run-time-instrumentation-halted interrupt occurred.
RETURN VALUE
On success, s390_runtime_instr() returns 0 and enables the thread for run-time instrumentation by assigning the thread a default run-time
instrumentation control block. The caller can then read and modify the control block and start the run-time instrumentation. On error, -1
is returned and errno is set to one of the error codes listed below.
ERRORS
EINVAL The value specified in command is not a valid command or the value specified in signum is not a real-time signal number.
ENOMEM Allocating memory for the run-time instrumentation control block failed.
EOPNOTSUPP
The run-time instrumentation facility is not available.
VERSIONS
This system call is available since Linux 3.7.
CONFORMING TO
This Linux-specific system call is available only on the s390 architecture. The run-time instrumentation facility is available beginning
with System z EC12.
NOTES
Glibc does not provide a wrapper for this system call, use syscall(2) to call it.
SEE ALSO
syscall(2), signal(7)
COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the
latest version of this page, can be found at https://www.kernel.org/doc/man-pages/.
Linux Programmer's Manual 2017-09-15 S390_RUNTIME_INSTR(2)