Sponsored Content
Operating Systems AIX VIOS - fibre adapters not seeing luns Post 302903392 by -=XrAy=- on Tuesday 27th of May 2014 09:59:31 AM
Old 05-27-2014
Quote:
Originally Posted by aixkidbee
Oh on another thought X-ray, what happens if on the switch the port comes up as FE - Fabric Extender?
Sorry no idea Smilie
 

6 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

2. AIX

20EE0008 : No adapters found Adapter, Riser, System Bd.

Hello, When I try to upgrade AIX from 5.1 to 5.3 I get this error message 20EE0008 : No adapters found Adapter, Riser, System Bd. Anyone know anything about it ? (1 Reply)
Discussion started by: filosophizer
1 Replies

3. Red Hat

Designating Default Gateway for multiple networks/adapters

Hi I have 4 NIC's connected to my RHEL 5.3 server. Two on one subnet creating bond0, and two on a second subnet which create bond1. Both bonds are set to use DHCP to obtain IP addresses. Here is the config file for ifcfg-bond0: DHCP_HOSTNAME=rrnltshckvmx001 DEVICE=bond0 BOOTPROTO=dhcp... (2 Replies)
Discussion started by: Padow
2 Replies

4. Windows & DOS: Issues & Discussions

Order of Adapters in Windows 7

I am trying to get my boss' ipad to print on our local printers, and rapidly coming to loathe the product. After several false starts I'm attempting to use the free WePrint application, running on a Windows machine, to "forward" our printers from it to the ipad over the local network. I've hit... (2 Replies)
Discussion started by: Corona688
2 Replies

5. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

6. AIX

VIO SEA Adapters

hi guys BTW pretty new to VIO I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8 # lsdev -Cc adapter | grep ent ent0 Available Logical Host Ethernet Port (lp-hea) ent1 Available Logical Host Ethernet Port (lp-hea) ent2 Available 04-20... (8 Replies)
Discussion started by: karlochacon
8 Replies
ppmtopgm(1)						      General Commands Manual						       ppmtopgm(1)

NAME
ppmtopgm - convert a portable pixmap into a portable graymap SYNOPSIS
ppmtopgm [ppmfile] DESCRIPTION
Reads a portable pixmap as input. Produces a portable graymap as output. The output is a "black and white" rendering of the original image, as in a black and white photograph. The quantization formula used is .299 r + .587 g + .114 b. Note that although there is a pgmtoppm program, it is not necessary for simple conversions from pgm to ppm , because any ppm program can read pgm (and pbm ) files automatically. pgmtoppm is for colorizing a pgm file. Also, see ppmtorgb3 for a different way of converting color to gray. And ppmdist generates a grayscale image from a color image, but in a way that makes it easy to differentiate the original colors, not necessarily a way that looks like a black and white photograph. QUOTE
Cold-hearted orb that rules the night Removes the colors from our sight Red is gray, and yellow white But we decide which is right And which is a quantization error. SEE ALSO
pgmtoppm(1),ppmtorgb3(1),rgb3toppm(1),ppmdist(1),ppm(5),pgm(5) AUTHOR
Copyright (C) 1989 by Jef Poskanzer. 10 April 2000 ppmtopgm(1)
All times are GMT -4. The time now is 03:45 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy