Sponsored Content
Operating Systems AIX Disk replacement on SharedVG. Post 302901715 by bakunin on Thursday 15th of May 2014 07:16:40 AM
Old 05-15-2014
You have asked in this thread a very similar question and the solution i suggested there can be used here too.

A "STALE" partition means it is mirrored but one of the mirror copies is not there any more. It is possible to remove the failed copy (most probably from the disk in question) from the LV and remirror it to another disk. Do not forget to remove the disk from the VG afterwards.

Also, do a "learning import" on the other cluster node to synchronize the new VG layout. For a learning import to work only one hdisk previously already known as to be part of the VG has to stay. (This is why you have to do 2 learning imports when you replace all disks in a VG.)

That the disk is "Available" means only that its electronics is still working and doing what it takes to communicate with the driver if ther is one. It can still be defective because its magnetic platter cannot be read by the (working) drive electronics.

I hope this helps.

bakunin
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
vxsplitlines(1M)														  vxsplitlines(1M)

NAME
vxsplitlines - show disks with conflicting configuration copies in a cluster SYNOPSIS
vxsplitlines [-g diskgroup] [-c daname] DESCRIPTION
If you import portions of a disk group on different systems, this can lead to conflicting configuration copies on the disks of the disk group. If the configuration information in a disk group is ambiguous, it may not be possible for Veritas Volume Manager to determine which config- uration copy is most up-to-date. (This is usually termed a serial split brain (SSB) condition when it occurs in a cluster.) You cannot import a disk group in this state unless you specify which disk's configuration copy to use. You can use the vxsplitlines command to see which disks in a disk group have conflicting configuration copies, and use this information together with your knowledge of the history of the disk groups' usage to determine which configuration copy is most valid. The output from vxsplitlines displays the vxdg commands that you can run to import the disk group using the available configuration copies. The -o selectcp option of the vxdg import command is used to select the configuration copy to use for the import. OPTIONS
-c daname Display the SSB IDs for each disk that are stored in the configuration copy on the disk specified by its disk access name. Note: Although the SSB IDs for some disks may match, this does not necessarily mean that those disks' configuration copies have recorded all the configuration changes. When viewed from some other configuration copies, the SSB IDs of the same disks may not match. -g diskgroup Specifies the disk group. If a disk group is not specified, the default disk group is used as determined from the rules on the vxdg(1M) manual page. EXAMPLES
Display the disks on each side of the split in the disk group newdg: vxsplitlines -g newdg Display the SSB IDs stored in the configuration copy on disk c2t4d0: vxsplitlines -g newdg -c c2t4d0 NOTES
The vxsplitlines is primarily intended to be used with private disk groups, but it also works with shared disk groups. The version number of the disk group must be 110 or greater. SEE ALSO
vxdg(1M) Veritas Volume Manager Administrator's Guide VxVM 5.0.31.1 24 Mar 2008 vxsplitlines(1M)