Sponsored Content
Operating Systems AIX Disk replacement on SharedVG. Post 302901715 by bakunin on Thursday 15th of May 2014 07:16:40 AM
Old 05-15-2014
You have asked in this thread a very similar question and the solution i suggested there can be used here too.

A "STALE" partition means it is mirrored but one of the mirror copies is not there any more. It is possible to remove the failed copy (most probably from the disk in question) from the LV and remirror it to another disk. Do not forget to remove the disk from the VG afterwards.

Also, do a "learning import" on the other cluster node to synchronize the new VG layout. For a learning import to work only one hdisk previously already known as to be part of the VG has to stay. (This is why you have to do 2 learning imports when you replace all disks in a VG.)

That the disk is "Available" means only that its electronics is still working and doing what it takes to communicate with the driver if ther is one. It can still be defective because its magnetic platter cannot be read by the (working) drive electronics.

I hope this helps.

bakunin
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
cmdk(7D)                                                              Devices                                                             cmdk(7D)

NAME
cmdk - common disk driver SYNOPSIS
cmdk@target, lun : [ partition | slice ] DESCRIPTION
The cmdk device driver is a common interface to various disk devices. The driver supports magnetic fixed disks and magnetic removable disks. The block-files access the disk using the system's normal buffering mechanism and are read and written without regard to physical disk records. There is also a "raw" interface that provides for direct transmission between the disk and the user's read or write buffer. A sin- gle read or write call usually results in one I/O operation; raw I/O is therefore considerably more efficient when many bytes are transmit- ted. The names of the block files are found in /dev/dsk; the names of the raw files are found in /dev/rdsk. I/O requests to the magnetic disk must have an offset and transfer length that is a multiple of 512 bytes or the driver returns an EINVAL error. Slice 0 is normally used for the root file system on a disk, slice 1 as a paging area (for example, swap), and slice 2 for backing up the entire fdisk partition for Solaris software. Other slices may be used for usr file systems or system reserved area. Fdisk partition 0 is to access the entire disk and is generally used by the fdisk(1M) program. FILES
/dev/dsk/cndn[s|p]n block device (IDE) /dev/rdsk/cndn[s|p]n raw device (IDE) where: cn controller n dn lun n (0-7) sn UNIX system slice n (0-15) pn fdisk partition(0) /kernel/drv/cmdk 32-bit kernel module. /kernel/drv/amd64/cmdk 64-bit kernel module. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
fdisk(1M), mount(1M), lseek(2), read(2), write(2), readdir(3C), scsi(4), vfstab(4), attributes(5), dkio(7I) SunOS 5.10 9 Oct 2004 cmdk(7D)
All times are GMT -4. The time now is 08:41 AM.