Sponsored Content
Operating Systems AIX Moving VIOS, LPAR's, HMC to different subnet Post 302892808 by spricer on Friday 14th of March 2014 02:43:38 PM
Old 03-14-2014
Code:
This sentence is not really true, because the connection to Manage  systems is through Private network and that is the reason you see Manage  systems with different subnets are connected to HMC...

I understand that private network is used to manage FSP's and let's forget remote access to HMC (I will work directly on HMC hardware in server room). Question is why I cannot access VIOS via HMC console if I change default gateway for eth1 in Network settings? (this automatically starts another question what would happen if I put wrong network parameters in VIOS, how am I suppose to access it?).
A well configuration of eth2 (reverted everything back) does not guarantee that I will have access to VIOS if I missconfigure it (according to the problem on eth1).
What I would like to see is that I can access VIOS from HMC (hardware side) via console no matter of eth1 settings, or default gateway. Currently this is not case if I change dafault gateway.
 

10 More Discussions You Might Find Interesting

1. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

2. AIX

To see vhost on VIOS after creating an HMC profile

I created a profile in HMC for a new LPAR and activated it but not yet installed AIX. Is there a step to make this new LPAR available as vhostX from the VIO server after creating and activating an HMC profile? I already shared the CD-ROM device from the HMC profile. Thanks. -... (1 Reply)
Discussion started by: learner1
1 Replies

3. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

4. AIX

What's the difference between VIOS and LPAR?

Hi All, Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great. ... (5 Replies)
Discussion started by: itik
5 Replies

5. AIX

Discovery LPAR from HMC

Hi All, i would like to know if it's possible to know all the IP Addresses of all LPAR's interfaces from HMC (without connect into LPAR). And if i can know also the "Application" hostname of LPAR from HMC. Thanks in advance. Bye Mario (2 Replies)
Discussion started by: Zio Bill
2 Replies

6. AIX

List LPAR from VIOS

Hi guys, does anyone know how to get a list of the LPAR running on VIOS? Thanks! (5 Replies)
Discussion started by: cecco16
5 Replies

7. AIX

VIOS LPAR Error 0518

I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518 Reference Code Selection 0518 (Time stamp: 12/18/12 12:10:20 AM UTC) Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC) AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Discussion started by: filosophizer
10 Replies

8. AIX

Command to show HMC of this lpar?

Does anyone know of a command that can be run on the lpar to show the name of the lpars managing HMC? We have a large environment and records a little old on which HMC manages which lpars....if i could login to an lpar and just issue a command to show me its managing hmc that would be great. (2 Replies)
Discussion started by: Foiled
2 Replies

9. UNIX for Beginners Questions & Answers

Hmc lpar console integration

We want to integrate powervm by using openstack with hmc. Now we encounter problem with the console, we can open the terminal within hmc, and I think hmc using tech java applet. sample applet code like <applet codebase="https://172.16.28.174/hmc/"... (0 Replies)
Discussion started by: eagle
0 Replies

10. AIX

IBM VIOS AIX HMC Error

hello P6 was managed by HMC, tried to install on it VIOS 2.2.6 and got this error message Hosting requires a hosting partition -- boot not permitted vios-4 - imgbb.com then after creating an lpar in HMC got this message B2001230 vios-3 - imgbb.com anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
Match-all classifier in tc(8)					       Linux					     Match-all classifier in tc(8)

NAME
matchall - traffic control filter that matches every packet SYNOPSIS
tc filter ... matchall [ skip_sw | skip_hw ] [ action ACTION_SPEC ] [ classid CLASSID ] DESCRIPTION
The matchall filter allows to classify every packet that flows on the port and run a action on it. OPTIONS
action ACTION_SPEC Apply an action from the generic actions framework on matching packets. classid CLASSID Push matching packets into the class identified by CLASSID. skip_sw Do not process filter by software. If hardware has no offload support for this filter, or TC offload is not enabled for the inter- face, operation will fail. skip_hw Do not process filter by hardware. EXAMPLES
To create ingress mirroring from port eth1 to port eth2: tc qdisc add dev eth1 handle ffff: ingress tc filter add dev eth1 parent ffff: matchall skip_sw action mirred egress mirror dev eth2 The first command creats an ingress qdisc with handle ffff: on device eth1 where the second command attaches a matchall filters on it that mirrors the packets to device eth2. To create egress mirroring from port eth1 to port eth2: tc qdisc add dev eth1 handle 1: root prio tc filter add dev eth1 parent 1: matchall skip_sw action mirred egress mirror dev eth2 The first command creats an egress qdisc with handle 1: that replaces the root qdisc on device eth1 where the second command attaches a matchall filters on it that mirrors the packets to device eth2. To sample one of every 100 packets flowing into interface eth0 to psample group 12: tc qdisc add dev eth0 handle ffff: ingress tc filter add dev eth0 parent ffff: matchall action sample rate 100 group 12 SEE ALSO
tc(8), iproute2 21 Oct 2015 Match-all classifier in tc(8)
All times are GMT -4. The time now is 01:23 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy