03-13-2014
Hi Bakunin,
Thank you for your detail explanation. Its is a good migration experience.
For our case, we are planing to buy all new set of server and its peripheral. (p7 server, IBM san switch, ibm SAN, tape library). And if we cannot connect the new server to old SAN, is it possible to install the AIX 7.1, power HA 7 ... first, and then any method to clone the data to new SAN (mid range SAN like DS4000).
Thx!
Ray
9 More Discussions You Might Find Interesting
1. AIX
Hi everybody,
I want ask if it is possible to copy all storage structure (VGs, LVs & filesystems) from one server to another. In other words, I want to move my system from old server to new one, so I want the new server exactly have the same sizes and number of VGs, LVs, & filesystems.
Thanks... (11 Replies)
Discussion started by: aldowsary
11 Replies
2. AIX
Can any one help.....
How will do migration through NIM server? (4 Replies)
Discussion started by: AIXlearner
4 Replies
3. Solaris
Hi All
We are having a very old server that is working on solaris 5.6 and oracle7.
now We are planning to migrate it to a Solaris 8 and oracle 9 environment.
The application software of the server is basically written in ProC and there are few sql ,perl and shell scripts on the server . We... (13 Replies)
Discussion started by: asalman.qazi
13 Replies
4. Shell Programming and Scripting
I am migrating from a host to another and I am trying to mimic the attributes on the old server.
Only problem is I can't figure out a fast way. Any recommendations?
Initially I thought about listing all my files on my previous host, but for some reason the listing of all files produced... (2 Replies)
Discussion started by: raykon
2 Replies
5. Linux
Hello, everyone. I've been lurking on this forum for a while but have never needed to post asking for a bit of help until now.
Long story short, I have a test of sorts scheduled with a prospective employer, a managed web hosting company, that involves migrating a hypothetical customer from... (2 Replies)
Discussion started by: Deputy Cartman
2 Replies
6. Solaris
Hi All,
I need your help urgently.
Below I have given the brief description of the Architecture and the Problem.
The brief details of the architecture:
We have 5 Containers(Non-Global Zones) running on one T5220 Box. The Global Zone is running Solaris 10.
The Non-global Zones are... (6 Replies)
Discussion started by: kamaldeep1986
6 Replies
7. Red Hat
Hi,
Can anyone help me on migration the print server from AIX to RHEL 4?
Appreciate your help? (1 Reply)
Discussion started by: brby07
1 Replies
8. UNIX and Linux Applications
Hi,
i have a server installed samba+openldap (pdc). Need to migration windows server 2003 (active directory) object users, computers.
Where you can read how to do it? Or can tell me how to do it?
Thanks.
P.S. Sorry for bad english (0 Replies)
Discussion started by: ap0st0l
0 Replies
9. Solaris
hi all,
i am refreshing my hardware, but i do not want to do a clean installation/reinstallation.
I am wondering if i could do
- do a ufsdump of the / partition (into a file on a nfs share)
- bootup using cdrom in the new machine
- mount the boot device/slice, and restore the ufsdump on... (7 Replies)
Discussion started by: javanoob
7 Replies
fp(7d) Devices fp(7d)
NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)