My question is:
i have a script called getevent
to run i just call ./getevent
can i convert this to make it binary executable and not letting my clients open it and see the code.??:(
I am using Solaris 8. (3 Replies)
All,
I want to convert multiple \0 005 characters to line feed 012 character
in a binary file to make to readable. Here is the sample od -c file
output:
0000000 254 355 \0 005 s r \0 * c o m . c i s c
Here is the sample od -b file output:
0000000 254 355 000... (0 Replies)
Hi frnds :)
I need a small help...
I have a very long file containing 20 digits decimal number which i want to convert into the corresponding 16 digit hexadecimal values.
File looks like....
11908486672755551741
05446378739602232559
04862605079740156652
.
.
.
I tried the script
for i... (7 Replies)
Hi,
I have got a library file, created by compiling C code. The file information with "file" command, gives it a "application/x-archive" type file. I want to extract the release string of my software from this file, so that i can know which version of C files were used to create the lib.
Can... (3 Replies)
Why would a binary which was compiled on a Solaris-10 not be runnable in a SunOS 5.10? (they are supposed to be precisely equivalent).
When I run the file command on it, it says:
ELF 32-bit LSB executable 80386 Version 1, dynamically linked, not stripped, no debugging information available... (10 Replies)
I have searched and the answers I have found thus far have led me to this point, so I feel I am just about there.
I am trying to convert a column of hexadecimal to decimal values so that I can filter out via grep just the data I want. I was able to pull my original 3 character hex value and... (10 Replies)
Hi Guys,
Is it possible to convert the hexadecimal to Binary by unix command.....I could not figure out....
If I need to convert AF6D to binary...what could be the way to do?
Thanks in advance!!
---------- Post updated at 02:57 AM ---------- Previous update was at 02:42 AM ----------
I... (6 Replies)
Dear all,
I am trying to write c-program to read the following file containing hexadecimal values (snippet of big data file).
I want to combine two hexadecimal values together like A0A03E01 and then would like to have the binary equivalent to perform further test on it. Unfortunately, it failed... (16 Replies)
Discussion started by: emily
16 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)