Old 01-08-2014
I'd say from the Hitachi storage point of view the LUN ID would be 0x1B on WWPN 50:06:0E:80:04:29:42:54

LUN ID 0x81 is probably what the client sees.

HTH
This User Gave Thanks to dukessd For This Post:
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Ids

What's the relationship beteew IDS and informix ? (1 Reply)
Discussion started by: wuhuatao
1 Replies

2. UNIX for Dummies Questions & Answers

can't su to any IDs

hello friends, i had this problem couldn't figure out. Every time i tried to su to an id by this command. it gave all killed command after that. Can't use it at all. ( OS Irix ). Any help greatly appreciated. ========= server 23# su - hbl3121 Killed Killed Killed Killed Killed Killed... (2 Replies)
Discussion started by: anphdula
2 Replies

3. Shell Programming and Scripting

Migrating IDs

I need a script that will move files and change the ownership from a user's old home directory to a new home directory on multiple NIS+ servers. (0 Replies)
Discussion started by: mackdaddy07
0 Replies

4. Cybersecurity

Bayesian IDS

Hi there, I am working on Anomaly based Network IDS... Statistical based technique is simple but not quite effective in real scenario... I understand Bayesian classifier/Network is more effective in the context of anomaly detection, but i have very little idea about Bayesian approach for... (0 Replies)
Discussion started by: Dinakara
0 Replies

5. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

6. AIX

Multiple IDs

Hello Guys, We've around 20 machines & I've root access for all of them. Also, we have around 4 different ID's in these machines. I have to change the passwords every month, I was wondering is there a way to change the password for multiple IDs at one shot? Thanks, (1 Reply)
Discussion started by: AbhijithS
1 Replies

7. Shell Programming and Scripting

common ids

I have file1.txt I have file2.txt and I want to extract all the rows in file1.txt that have the same idsas file2.txt in the 3rd column in the file1.txt. so the output willl be I have tried sort ${data}/13.txt > ${data}/13 sort -k3,3 ${data}/333.txt > ${data}/333 awk... (4 Replies)
Discussion started by: johnkim0806
4 Replies

8. Shell Programming and Scripting

Match ids

Hello, I have two files File 1 with 10 columns rsid position ........ xx 1:10000 File 2 position 1:10000 2:2000 .... I need to extract the IDs given in file 2(column1) from file 1 (column2) and print all columns from file1. I am trying this command (1 Reply)
Discussion started by: nans
1 Replies

9. UNIX for Beginners Questions & Answers

List of all ids,groups, privilege ids

I wish to pull out a list of all user ids on the system, including the privileged ids, the groups to which they belong to. Sometimes after deleting an id also, its home dir does not get deleted or an entry is left behind in /etc/passwd. Can someone help me with a script to achieve both. (2 Replies)
Discussion started by: ggayathri
2 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 09:27 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy