Sponsored Content
Special Forums Hardware HP9000 Server - Stuck on RAID0 Post 302882367 by cjcox on Monday 6th of January 2014 11:15:06 AM
Old 01-06-2014
You should be able to find 18G LVD SCSI drives. HP used to make their machines with HVD drives... what a pain that was!

With regards to backups, etc. that could be more complicated. I think that unit has external SCSI, if so, you may be able to hook some extra space up that way and back things up.

If possible, I'd backup the data, and start from scratch with a new install with a different RAID config.
These 2 Users Gave Thanks to cjcox For This Post:
 

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

stuck in perl cgi to upload a file to server

hi, i m working on a perl cgi script which uploads a file to the server. i m stuck. i hav written the errors. plz help. Sachin Kaw ______________________________________________________________________ #!/usr/bin/perl -w use CGI; use CGI qw(:standard); use strict; use POSIX... (4 Replies)
Discussion started by: sachin_kaw
4 Replies

2. UNIX for Dummies Questions & Answers

Upgrade HP9000 HP-UX 10.20 to 11.00

To all expert members, i need your help. We have an existing HP9000 K-Class 32-bit with HP-UX 10.20 OS installed and we would like to upgrade it to HP-UX 11.00. I am not really confident in doing upgrades in our system because i don't have any experience or trainings on this. If somebody can... (3 Replies)
Discussion started by: Tris
3 Replies

3. Solaris

Solaris RAID0 doubt...

friends, Suppose I am typing metastat command and it is showing: d100: Concat/Stripe Size: 369495 blocks (180 MB) Stripe 0: (interlace: 32 blocks) Device Start Block Dbase Reloc c1d0s0 16065 Yes Yes c1d0s1 0 No Yes... (4 Replies)
Discussion started by: saagar
4 Replies

4. Linux

Raid0 recovery from external HD

Hi, I have the Lacie Big Disk, which is a external hard drive enclosure in a hardware RAID0 array of 2x250GB disks. The RAID controller seems to have died, leaving me with 2 working hard drives but no way to get the data. I tried hooking the drives up to a windows machine and using Raid... (4 Replies)
Discussion started by: dangral
4 Replies

5. UNIX for Dummies Questions & Answers

Why is RAID0 faster?

I have read anecdotes about people installing RAID0 (RAID - Wikipedia, the free encyclopedia) on some of their machines because it gives a performance boost. Because bandwidth on the motherboard is limited, can someone explain exactly why it should be faster? (7 Replies)
Discussion started by: figaro
7 Replies

6. HP-UX

LV and/or physical drive problems HP9000

I'm a technician who has been called upon to troubleshoot an ancient HP9000 K260, running HP UX 11.11. After a power sag/crash/restart FSCK gave multiple error/warning messages about logical volumes and groups. I have some modest experience with Unix servers, but not on such an old and... (2 Replies)
Discussion started by: patrick.scalia
2 Replies

7. HP-UX

HP9000 Container - NFS Issue

I am running HP9000 Containers version A.03.01. I have the container up and running. I now need to mount an exported file system from another HPUX server with both read and write permissions. I can get the mount okay but from the container I cannot read or write properly to the mounted file... (2 Replies)
Discussion started by: PaleRider
2 Replies

8. UNIX for Advanced & Expert Users

Home email server setup - stuck

Hello, Firstly, I am using Debian 7.1, updated (as of today), I installed postfix, sasl, and dovecot. I have read through various online tutorials and quick installation guides, videos etc. And, ventured into the actual text of postfix, sasl and dovecot. Everything is installed and "appears"... (5 Replies)
Discussion started by: jalisco
5 Replies

9. UNIX for Dummies Questions & Answers

Raid0 array stresses only 1 disk out of 3

Hi there, I've setup a raid0 array of 3 identical disks using : mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity : dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Discussion started by: chebarbudo
8 Replies
AMR(4)                                                     BSD Kernel Interfaces Manual                                                     AMR(4)

NAME
amr -- MegaRAID SCSI/ATA/SATA RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device amr Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): amr_load="YES" DESCRIPTION
The amr driver provides support for LSI Logic MegaRAID SCSI, ATA and SATA RAID controllers and legacy American Megatrends MegaRAID SCSI RAID controllers, including models relabeled and sold by Dell and Hewlett-Packard. LSI MegaRAID SAS controllers are supported by mfi(4) and will not work with this driver. HARDWARE
Controllers supported by the amr driver include: o MegaRAID SATA 150-4 o MegaRAID SATA 150-6 o MegaRAID SATA 300-4X o MegaRAID SATA 300-8X o MegaRAID SCSI 320-1E o MegaRAID SCSI 320-2E o MegaRAID SCSI 320-4E o MegaRAID SCSI 320-0X o MegaRAID SCSI 320-2X o MegaRAID SCSI 320-4X o MegaRAID SCSI 320-0 o MegaRAID SCSI 320-1 o MegaRAID SCSI 320-2 o MegaRAID SCSI 320-4 o MegaRAID Series 418 o MegaRAID i4 133 RAID o MegaRAID Elite 1500 (Series 467) o MegaRAID Elite 1600 (Series 493) o MegaRAID Elite 1650 (Series 4xx) o MegaRAID Enterprise 1200 (Series 428) o MegaRAID Enterprise 1300 (Series 434) o MegaRAID Enterprise 1400 (Series 438) o MegaRAID Enterprise 1500 (Series 467) o MegaRAID Enterprise 1600 (Series 471) o MegaRAID Express 100 (Series 466WS) o MegaRAID Express 200 (Series 466) o MegaRAID Express 300 (Series 490) o MegaRAID Express 500 (Series 475) o Dell PERC o Dell PERC 2/SC o Dell PERC 2/DC o Dell PERC 3/DCL o Dell PERC 3/QC o Dell PERC 4/DC o Dell PERC 4/IM o Dell PERC 4/SC o Dell PERC 4/Di o Dell PERC 4e/DC o Dell PERC 4e/Di o Dell PERC 4e/Si o Dell PERC 4ei o HP NetRAID-1/Si o HP NetRAID-3/Si (D4943A) o HP Embedded NetRAID o Intel RAID Controller SRCS16 o Intel RAID Controller SRCU42X DIAGNOSTICS
Driver initialisation/shutdown phase amr%d: memory window not available amr%d: I/O window not available The PCI BIOS did not allocate resources necessary for the correct operation of the controller. The driver cannot attach to this controller. amr%d: busmaster bit not set, enabling The PCI BIOS did not enable busmaster DMA, which is required for the correct operation of the controller. The driver has enabled this bit and initialisation will proceed. amr%d: can't allocate register window amr%d: can't allocate interrupt amr%d: can't set up interrupt amr%d: can't allocate parent DMA tag amr%d: can't allocate buffer DMA tag amr%d: can't allocate scatter/gather DMA tag amr%d: can't allocate s/g table amr%d: can't allocate mailbox tag amr%d: can't allocate mailbox memory A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. amr%d: can't obtain configuration data from controller amr%d: can't obtain product data from controller The driver was unable to obtain vital configuration data from the controller. Initialisation has failed and the driver will not attach to this controller. amr%d: can't establish configuration hook amr%d: can't scan controller for drives The scan for logical drives managed by the controller failed. No drives will be attached. amr%d: device_add_child failed amr%d: bus_generic_attach returned %d Creation of the logical drive instances failed; attachment of one or more logical drives may have been aborted. amr%d: flushing cache... The controller cache is being flushed prior to shutdown or detach. Operational diagnostics amr%d: I/O beyond end of unit (%u,%d > %u) A partitioning error or disk corruption has caused an I/O request beyond the end of the logical drive. This may also occur if FlexRAID Vir- tual Sizing is enabled and an I/O operation is attempted on a portion of the virtual drive beyond the actual capacity available. amr%d: polled command timeout An initialisation command timed out. The initialisation process may fail as a result. amr%d: bad slot %d completed The controller reported completion of a command that the driver did not issue. This may result in data corruption, and suggests a hardware or firmware problem with the system or controller. amr%d: I/O error - %x An I/O error has occurred. SEE ALSO
cd(4), da(4), mfi(4), sa(4), scsi(4) AUTHORS
The amr driver was written by Mike Smith <msmith@FreeBSD.org>. This manual page was written by Mike Smith <msmith@FreeBSD.org> and Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org>. BSD March 29, 2006 BSD
All times are GMT -4. The time now is 09:56 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy