12-17-2013
Output from netstat -s would be good to see, even if it is a bit long.
Do you have a problem in FTP speed when you compare speeds just within company B?
We had a problem once where the auto-negotiation was wrong and we had a switch at 100M-Full duplex with a servers at 10M-Half. It all worked fine until we forced lots of data with an FTP, so it was difficult to track down.
You might need to ask the network manager to display the switch ports settings. You may be able to give IP address, or they may require the MAC address of your network card.
I regret I do not know how to display the requested and negotiated speeds on OSR. Can anyone else chip in?
Robin
8 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
This isn't really a unix question, or even a programming question, but I hope you guys can help. I want to create a program to control the electricity on a model railway.
I have created the program to that it sends characters over the serial cable, but now I need to do the switch that will... (1 Reply)
Discussion started by: KrazyGuyPaul
1 Replies
2. Filesystems, Disks and Memory
Hello,
I have a Supermicro server with a P4SCI mother board running Debian Sarge 3.1. This is the "dmidecode" output related to RAM info:
RAM speed information is incomplete.. "Current Speed: Unknown", is there anyway/soft to get the speed of installed RAM modules? thanks!!
Regards :)... (0 Replies)
Discussion started by: Santi
0 Replies
3. Solaris
Hi,
Can anyone suggest a Unix command or c-shell algorithm to simulate to behavior of "wall" command minus the "all users"? What I'm trying to do is to send a notice to just one particular user but i dont want other remotely-logged-on users to receive the message (on the pseudo-terminals). I... (3 Replies)
Discussion started by: Deanne
3 Replies
4. HP-UX
HI ALL,
I have been trying to install a particular software using remote linux server.
some thing like this:
rsh <host ID> /usr/sbin/swinstall -x autoreboot=true -s /tmp/<software> <Product name>.
The problem is whenever I try to install the product through a shell script the installation... (1 Reply)
Discussion started by: barun agarwal
1 Replies
5. Cybersecurity
Hey GUys,
Once again I run in to problem and I am here for ur help.
I have two sun(solaris) box on company LAN.
One Unix Box is behind the firewall and the other one is Outside the firewall. The thing i need to do is
remote display a graphic on Unix box outside the firewall to the Unixbox... (5 Replies)
Discussion started by: ajnabi
5 Replies
6. UNIX for Dummies Questions & Answers
Hiya Everybody just joined,
Not sure if this is the right section:o
I require abit of an assistance with IPC!
I know there are different types of IPC porcesses like signals, semaphores, mutexes, shared memory, message queues, pipes and sockets.
Now say a system has a number of... (4 Replies)
Discussion started by: G.I.Joe
4 Replies
7. Filesystems, Disks and Memory
I analysed disk performance with blktrace and get some data:
read:
8,3 4 2141 2.882115217 3342 Q R 195732187 + 32
8,3 4 2142 2.882116411 3342 G R 195732187 + 32
8,3 4 2144 2.882117647 3342 I R 195732187 + 32
8,3 4 2145 ... (1 Reply)
Discussion started by: W.C.C
1 Replies
8. What is on Your Mind?
I have been wondering how do Systems Administrators do the jump into Systems Engineering? Is it only a matter of time and experience or could I actually help myself get there?
Opinions? Books I could read?
Thanks a lot for your help! (0 Replies)
Discussion started by: svalenciatech
0 Replies
LEARN ABOUT HPUX
cfsetospeed
cfspeed(3C) cfspeed(3C)
NAME
cfgetospeed(), cfsetospeed(), cfgetispeed(), cfsetispeed() - tty baud rate functions
SYNOPSIS
DESCRIPTION
These functions set and get the input and output speed codes in the termios structure referenced by termios_p. The termios structure con-
tains these speed codes representing input and output baud rates as well as other terminal related parameters. Setting the parameters on a
terminal file does not become effective until is successfully called.
returns the output speed code from the
termios structure referenced by termios_p.
sets the output speed code in the
termios structure referenced by termios_p to speed. The speed code for a baud rate of zero, is used to termi-
nate the connection. If is specified, the modem control lines are no longer asserted, which normally discon-
nects the line.
returns the input speed code from the
termios structure referenced by termios_p.
sets the input speed code in the
termios structure referenced by termios_p to speed.
RETURN VALUE
returns the output speed code from the termios structure referenced by termios_p.
returns the input speed code from the termios structure referenced by termios_p.
and return zero upon successful completion. Otherwise, they return -1 and set to indicate the error.
ERRORS
and fail when the following condition is encountered:
[EINVAL] The value of speed is outside the range of possible speed codes as specified in
WARNINGS
and can be used to set speed codes in the termios structure that are not supported by the terminal hardware.
SEE ALSO
tcattribute(3C), thread_safety(5), termio(7).
STANDARDS CONFORMANCE
cfspeed(3C)