Sponsored Content
Top Forums Shell Programming and Scripting Removing blank space using VI Post 302877900 by ksgnathan on Tuesday 3rd of December 2013 07:36:52 PM
Old 12-03-2013
Removing blank space using VI

Hi,

How to remove blank spaces using vi (I am using AIX)?

Code:
#cat siva.txt
AAA    BBB
CCC    DDD
EEE    FFF

Need to remove space between 2 columns.

Regards,
Siva
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Removing blank spaces from a file?

Guys, I need some help... how can I remove the blank spaces between the lines below? (between the date and the hour fields) 21/05/07 00:05:00 99 21/05/07 00:10:01 99 21/05/07 00:15:00 99 21/05/07 00:20:00 99 21/05/07 00:25:00 99 I want to make the file... (4 Replies)
Discussion started by: dfs
4 Replies

2. Shell Programming and Scripting

Removing Blank Lines

Hi i have the below lines from a file 7538 PRGRP450800PERSONAL SOAP AND BATH ADDITIV 7036 PRGRP450800PERSONAL SOAP AND BATH ADDITIV 7036 PRGRP450800PERSONAL SOAP AND BATH ADDITIV 7036... (3 Replies)
Discussion started by: dhanamurthy
3 Replies

3. Shell Programming and Scripting

removing duplicate blank lines

Hi, how to remove the blank lines from the file only If we have more than one blank line. thanks rameez (8 Replies)
Discussion started by: rameezrajas
8 Replies

4. Shell Programming and Scripting

Removing blank lines from comma seperated and space seperated file.

Hi, I want to remove empty/blank lines from comma seperated and space seperated files Thanks all for help (11 Replies)
Discussion started by: pinnacle
11 Replies

5. UNIX for Dummies Questions & Answers

Removing blank lines in a file

Hi I have a text file that has blank lines at different places. How to remove all the blank lines in a file? Thanks Ashok (3 Replies)
Discussion started by: ashok.k
3 Replies

6. Solaris

Removing blank spaces

Hi , I want to go out of vi editor temporarily and execute a command in command prompt and again going back to the editor . Is it possible . Any help on this is really helpful. 1. Need to open vi 2. Temporarily come out and execute a command and go back to vi editor (6 Replies)
Discussion started by: rogerben
6 Replies

7. Shell Programming and Scripting

Removing blank space in file

TT0000013101257 | JCJMMUJMMUB018 ... (0 Replies)
Discussion started by: sususa
0 Replies

8. UNIX for Dummies Questions & Answers

Removing blank lines not working

In my bash script I want to echo lines in a file and ensure no blank lines are echoed:for i in $(cat txt) do echo $i | sed 's/|/ /g;s/ SEARCHTERM$//g;s/ /\r\n/g;s/^$/d' done Keep in mind this is a fragment so ignore the fact that the for loop is not closed. When I add the "s/^$/d' per... (12 Replies)
Discussion started by: MaindotC
12 Replies

9. Shell Programming and Scripting

Removing blank lines from a file

Hi All, How do i remove continuos blank lines from a file. I have a file with data: abc; def; ghi; jkl; mno; pqr; In the above file, there are two blank lines. I want to remove, one out of them. My output should look like: (2 Replies)
Discussion started by: raosr020
2 Replies

10. Shell Programming and Scripting

Removing blank lines

Hi, my input file is like this I want to remove the blank line. "/home/rit/sandbox/garuda/data/test/woman/T_RITK_F0008_ML_100080039.lab" r a N e l a k sh a m . "/home/rit/sandbox/garuda/data/test/woman/T_RITK_F0008_ML_100070453.lab" a v a s (4 Replies)
Discussion started by: sreejithalokkan
4 Replies
BESTUPS(8)							    NUT Manual								BESTUPS(8)

NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option. Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not known. This driver does not support some older Best/SOLA units. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): nombattvolt=num Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports battery.charge values just below 100% even when it's completely charged. If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good battery. The author's Best Fortress 750 uses nombattvolt=27.4. battvoltmult=num Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage. For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this particular case you can set battvoltmult = 12 in ups.conf(8) to fix this. ID=string Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F AAA is the three-character identification for the UPS model. BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9. CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC. DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC. EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts DC and a decimal point is present. FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for 700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F. Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0". BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver. Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes back on-line, so you can't tell when it is really recharged. Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use nombattvolt= in ups.conf(8) to fix this. AUTHOR
Russell Kroll, Jason White SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 BESTUPS(8)
All times are GMT -4. The time now is 07:51 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy