11-13-2013
I am not sure if i understand you correctly. If you mean that you want to see the underlying RAIDs from within the system the LUN is attached to: no, you can't. You can't because these are different logical levels of abstraction.
For the system where the LUN is attached to a "disk" is a disk, regardless from what hardware it is constructed. Virtually, the Clariion exports a (vSCSI) disk simply not telling the target system from what it is made of. The target system connects to this disk using a (virtualized) SCSI protocol. Basically, the traget system treats the disk like it would be a locally connected SCSI drive, not caring for what is "underneath" this abstraction.
I hope this helps.
bakunin
10 More Discussions You Might Find Interesting
1. AIX
I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
Discussion started by: scottsl
0 Replies
2. AIX
Hi All,
I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX?
Is that going to boot on SAN rootvg volume?
Thanks in advance,
itik (3 Replies)
Discussion started by: itik
3 Replies
3. AIX
We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies
4. AIX
To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies
5. AIX
Steps to upgrade AIX TL ( technology Level ) / Maintenance Level in AIX ( including Firmware HMC VIOS )
This article or post covers upgrades for
- Hardware Management Console ( HMC )
- Firmware ( also known as microcode )
- VIO ( Virtual I/O Server = PowerVM )
- AIX Version, Technology... (2 Replies)
Discussion started by: filosophizer
2 Replies
6. Solaris
Hi,
I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk.
I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error.
... (6 Replies)
Discussion started by: Mack1982
6 Replies
7. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
8. AIX
Hi Admins,
What is the command to check the RAID level in aix 5.3
I have a vg with 5 disks.I want to check the raid level.
Regards
newaix (1 Reply)
Discussion started by: newaix
1 Replies
9. AIX
Hello Folks,
I have directly connected my IBM Pseries AIX machine to SAN Storage
I have a dual port Fibre Channel Adapter
Connected both fiber ports to SAN Box IBM DS4500 Controller A & Controller B
Using IBM DS storage manager client 10 -- created one logical disk and assigned to a... (18 Replies)
Discussion started by: filosophizer
18 Replies
10. AIX
Hi guys, :)
I'm a studient in IT field (AIX)
I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00)
I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN
root@localhost # lscfg | grep hdisk
+ hdisk7 ... (13 Replies)
Discussion started by: Tharsan
13 Replies
SCSI(4) Kernel Interfaces Manual SCSI(4)
Name
SCSI - Small Computer System Interconnect
Description
The ULTRIX system interfaces to disk and tape devices through the Small Computer System Interconnect (SCSI). Initial ULTRIX SCSI support
is limited to the Digital-supplied mass storage devices. The following devices are fully supported on the ULTRIX system:
o Winchester disks: RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33
o Magnetic tapes: TZ30, TZK50, TLZ04, TSZ05, TKZ08, TZK10
o Optical disks: RRD40, RRD42
Under the ULTRIX operating system, a SCSI device is referred to by its logical name. Logical names take the following form:
nn#
The nn argument is the two-character name; the number sign (#) represents the unit number. The two character names for SCSI devices are:
rz - RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33, RRD40, RRD42 disks
tz - TZ30, TZK50, TLZ04, TSZ05, TKZ08, and TZK10 tapes
The unit number is a combination of the SCSI bus number, either 0, 1, ... and the device's target ID number. The unit number is eight
times the bus number plus the target ID. For example, an RZ23 disk at target ID 3 on bus 0 would be referred to as rz3; a TZK50 tape at
target ID 5 on the second SCSI bus would be referred to as 13.
The SCSI bus has eight possible target device IDs. By default, one is allocated to the system. This allows for a maximum of seven target
devices connected to a SCSI bus.
Restrictions
The ULTRIX SCSI device driver does not operate with optical disks, other than the Digital-supplied devices.
The SCSI driver attempts to support on a best effort basis, non-Digital-supplied winchester disks and magnetic tapes.
The following notes apply to the driver's handling of non-Digital-supplied disks:
o These disks are assigned a device type of RZxx, instead of RZ22, RZ23, RZ23L, RZ55, RZ56, RZ57, RX23, RX26, or RX33. The RZxx disks
follow the same logical device naming scheme as the Digital-supplied disks.
o During the autoconfigure phase of the system startup, the driver prints the contents of the SCSI vendor ID, product ID, and the
revision level fields of the inquiry data return by the SCSI device.
o RZxx disks are assigned a default partition table. The default table can be modified by editing the sz_rzxx_sizes[8] entry in the
file The utility can also be used to modify the partition table on a RZxx disk.
o The only logical unit number (LUN) supported for each target ID is 0.
See Also
rz(4), tz(4), chpt(8)