11-13-2013
I am not sure if i understand you correctly. If you mean that you want to see the underlying RAIDs from within the system the LUN is attached to: no, you can't. You can't because these are different logical levels of abstraction.
For the system where the LUN is attached to a "disk" is a disk, regardless from what hardware it is constructed. Virtually, the Clariion exports a (vSCSI) disk simply not telling the target system from what it is made of. The target system connects to this disk using a (virtualized) SCSI protocol. Basically, the traget system treats the disk like it would be a locally connected SCSI drive, not caring for what is "underneath" this abstraction.
I hope this helps.
bakunin
10 More Discussions You Might Find Interesting
1. AIX
I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
Discussion started by: scottsl
0 Replies
2. AIX
Hi All,
I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX?
Is that going to boot on SAN rootvg volume?
Thanks in advance,
itik (3 Replies)
Discussion started by: itik
3 Replies
3. AIX
We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies
4. AIX
To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies
5. AIX
Steps to upgrade AIX TL ( technology Level ) / Maintenance Level in AIX ( including Firmware HMC VIOS )
This article or post covers upgrades for
- Hardware Management Console ( HMC )
- Firmware ( also known as microcode )
- VIO ( Virtual I/O Server = PowerVM )
- AIX Version, Technology... (2 Replies)
Discussion started by: filosophizer
2 Replies
6. Solaris
Hi,
I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk.
I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error.
... (6 Replies)
Discussion started by: Mack1982
6 Replies
7. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
8. AIX
Hi Admins,
What is the command to check the RAID level in aix 5.3
I have a vg with 5 disks.I want to check the raid level.
Regards
newaix (1 Reply)
Discussion started by: newaix
1 Replies
9. AIX
Hello Folks,
I have directly connected my IBM Pseries AIX machine to SAN Storage
I have a dual port Fibre Channel Adapter
Connected both fiber ports to SAN Box IBM DS4500 Controller A & Controller B
Using IBM DS storage manager client 10 -- created one logical disk and assigned to a... (18 Replies)
Discussion started by: filosophizer
18 Replies
10. AIX
Hi guys, :)
I'm a studient in IT field (AIX)
I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00)
I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN
root@localhost # lscfg | grep hdisk
+ hdisk7 ... (13 Replies)
Discussion started by: Tharsan
13 Replies
LEARN ABOUT SUNOS
metaimport
metaimport(1M) metaimport(1M)
NAME
metaimport - imports disk sets into existing Solaris Volume Manager configurations
SYNOPSIS
metaimport -s setname [-n] [-v] [-f] [disks...]
metaimport -r [disks...]
metaimport -V
metaimport -?
The metaimport command allows the importing of disk sets, including replicated disk sets, into an existing Solaris Volume Manager configu-
ration. Replicated disk sets are disk sets created using remote replication software.
The default Solaris Volume Manager configuration specifies a maximum number of disk sets that can be configured. The metaimport command
fails if importing the disk set would result in exceeding the number of disk sets configured on the system. To increase the number of disk
sets allowed on a system, see the .
Use metaset(1M) or metastat(1M) to view the configuration of the imported set.
You must run metaimport as root.
metaimport requires a functional Solaris Volume Manager configuration before it runs.
The following options are supported:
-f Force the import, even if a quorum of replicas from the imported disk set is not available. This option could
result in corrupt configurations and should only be used when metaimport fails with the "Insufficient quorum
detected; exiting" error. If only a partial disk set is available, this option might be necessary to successfully
import. Some or all data could be corrupted or unavailable when importing a partial set or a set lacking a replica
quorum.
-n Does not actually perform the operation, but shows the output or errors that would have resulted from the opera-
tion, had it been run.
-r Report on the non-configured disk sets found on the system. If no disk device or LUN is specified, metaimport
reports on all non-configured disk sets attached to the system. When the name of one disk is specified, metaimport
reports on the disk set (or virtual LUN) containing the specified disk. If two or more disks are specified, metaim-
port reports on the set (or sets, if they belong to different disk sets) containing the specified disks. If two or
more disks are specified, metaimport reports on the set (or sets, if they belong to different disk sets) containing
the specified disks.
-s setname Specify the disk set name to use when importing. The imported disk set will be called setname, without regard to
the name it may have had on a different system.
-v Verbose. Provides detailed information about the metadb replica location and status.
-V Version information.
-? Display a help message.
Example 1: Importing a Disk Set
The following example creates a disk set called blue and identifies c1t5d0 as a disk containing a state database replica from the disk set
being imported.
# metaimport -s blue c1t5d0
Example 2: Reporting Disk Sets to Import
The following example scans all disks and LUNs attached to the system and configured as part of the system. It scans for disks that could
be part of a disk set to be imported. Components that are already part of the Solaris Volume Manager configuration are ignored.
This use of metaimport provides suggested forms of the metaimport command to use to actually import the disk sets that have been found. You
can specify a component on the command line to reduce the scope of the scan and generate results more quickly.
# metaimport -r
0 Successful completion.
>0 An error occurred.
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWmdu |
+-----------------------------+-----------------------------+
|Interface Stability |Stable |
+-----------------------------+-----------------------------+
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M),
metarecover(1M), metareplace(1M), metaroot(1M), metaset(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), attributes(5)
16 May 2005 metaimport(1M)