Sponsored Content
Operating Systems Solaris [solved] How to blink faulty disk in Solaris hardware? Post 302868169 by manalisharmabe on Saturday 26th of October 2013 09:00:53 AM
Old 10-26-2013
This is solved.

Thanks a lot guys.
 

10 More Discussions You Might Find Interesting

1. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

2. Solaris

Solaris 10 installation issue Error 25: Disk cannot be read - Solved

Hi all, I guess most of you have seen this error message while installing Solaris 10 on an x86 platform. I got the error message while installing from DVD ISO on my home VMWare ESXi server. It took me a long time to figure the exact issue and a subsequent solution. the solution is very... (1 Reply)
Discussion started by: admin_xor
1 Replies

3. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. UNIX for Advanced & Expert Users

[Solved] Add hardware in virt-install command

Hi, Again a question about virt-install. Someone knows how to add hardware in the virt-install command? I put the first disk with --disks path=/.... but I need a second disk and I don't know how to include it? Thanks (2 Replies)
Discussion started by: hiddenshadow
2 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
SLAGTS(l)								 )								 SLAGTS(l)

NAME
SLAGTS - may be used to solve one of the systems of equations (T - lambda*I)*x = y or (T - lambda*I)'*x = y, SYNOPSIS
SUBROUTINE SLAGTS( JOB, N, A, B, C, D, IN, Y, TOL, INFO ) INTEGER INFO, JOB, N REAL TOL INTEGER IN( * ) REAL A( * ), B( * ), C( * ), D( * ), Y( * ) PURPOSE
SLAGTS may be used to solve one of the systems of equations (T - lambda*I)*x = y or (T - lambda*I)'*x = y, where T is an n by n tridiagonal matrix, for x, following the factorization of (T - lambda*I) as (T - lambda*I) = P*L*U , by routine SLAGTF. The choice of equation to be solved is controlled by the argument JOB, and in each case there is an option to perturb zero or very small diagonal elements of U, this option being intended for use in applications such as inverse iteration. ARGUMENTS
JOB (input) INTEGER Specifies the job to be performed by SLAGTS as follows: = 1: The equations (T - lambda*I)x = y are to be solved, but diagonal elements of U are not to be perturbed. = -1: The equa- tions (T - lambda*I)x = y are to be solved and, if overflow would otherwise occur, the diagonal elements of U are to be per- turbed. See argument TOL below. = 2: The equations (T - lambda*I)'x = y are to be solved, but diagonal elements of U are not to be perturbed. = -2: The equations (T - lambda*I)'x = y are to be solved and, if overflow would otherwise occur, the diagonal elements of U are to be perturbed. See argument TOL below. N (input) INTEGER The order of the matrix T. A (input) REAL array, dimension (N) On entry, A must contain the diagonal elements of U as returned from SLAGTF. B (input) REAL array, dimension (N-1) On entry, B must contain the first super-diagonal elements of U as returned from SLAGTF. C (input) REAL array, dimension (N-1) On entry, C must contain the sub-diagonal elements of L as returned from SLAGTF. D (input) REAL array, dimension (N-2) On entry, D must contain the second super-diagonal elements of U as returned from SLAGTF. IN (input) INTEGER array, dimension (N) On entry, IN must contain details of the matrix P as returned from SLAGTF. Y (input/output) REAL array, dimension (N) On entry, the right hand side vector y. On exit, Y is overwritten by the solution vector x. TOL (input/output) REAL On entry, with JOB .lt. 0, TOL should be the minimum perturbation to be made to very small diagonal elements of U. TOL should normally be chosen as about eps*norm(U), where eps is the relative machine precision, but if TOL is supplied as non-positive, then it is reset to eps*max( abs( u(i,j) ) ). If JOB .gt. 0 then TOL is not referenced. On exit, TOL is changed as described above, only if TOL is non-positive on entry. Otherwise TOL is unchanged. INFO (output) INTEGER = 0 : successful exit element of the solution vector x. This can only occur when JOB is supplied as positive and either means that a diagonal element of U is very small, or that the elements of the right-hand side vector y are very large. LAPACK version 3.0 15 June 2000 SLAGTS(l)
All times are GMT -4. The time now is 05:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy