10-23-2013
If you have a service contract, the caseowner should provide a todo list for the intervention. If there is no action plan, ask the caseowner for help.
Outputs of metastat und format would be helpfull for detailed advice on your problem. If you have explorer installed, you should provide an explorer output to the caseowner.
This User Gave Thanks to DukeNuke2 For This Post:
10 More Discussions You Might Find Interesting
1. AIX
Hi Experts,
I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics.
pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D
SSA160 Physical Disk Drive ( MB)
Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies
2. Solaris
Hi all,
I guess most of you have seen this error message while installing Solaris 10 on an x86 platform. I got the error message while installing from DVD ISO on my home VMWare ESXi server.
It took me a long time to figure the exact issue and a subsequent solution. the solution is very... (1 Reply)
Discussion started by: admin_xor
1 Replies
3. Solaris
Hi folk,
I have this hardware faunty message, but dont know which hardware is this ? can you guide me ?
--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies
4. Solaris
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies
5. HP-UX
Requirement to remove a faulty mirrored disk from hp-ux LVM
<root@pdwp1s>/etc # vgdisplay -v /dev/vg00
vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies
6. HP-UX
Hi,
Have mirrored the primary disk to 3 .
Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
# strings /etc/lvmtab
/dev/vg00
+F@<
/dev/dsk/c1t2d0
/dev/dsk/c2t2d0
/dev/dsk/c2t0d0
But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies
7. HP-UX
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies
8. Solaris
Hi,
I'm trying to generate an alert related to Power Supply Failure.
As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty"
Any ideas are welcome and highly appreciated
-Thanks (3 Replies)
Discussion started by: justsam
3 Replies
9. UNIX for Advanced & Expert Users
Hi,
Again a question about virt-install.
Someone knows how to add hardware in the virt-install command?
I put the first disk with --disks path=/.... but I need a second disk and I don't know how to include it?
Thanks (2 Replies)
Discussion started by: hiddenshadow
2 Replies
10. UNIX for Beginners Questions & Answers
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
LEARN ABOUT DEBIAN
lps2torx
LPS2TORX(1) User Commands LPS2TORX(1)
NAME
lps2torx - provide TorX explorer interface to an LPS
SYNOPSIS
lps2torx [OPTION]... INFILE
DESCRIPTION
Provide a TorX explorer interface to the LPS in INFILE.
The LPS can be explored using TorX as described in torx_explorer(5).
OPTIONS
OPTION can be any of the following:
-y, --dummy
replace free variables in the LPS with dummy values
-rNAME, --rewriter=NAME
use rewrite strategy NAME:
'jitty' for jitty rewriting (default),
'jittyc' for compiled jitty rewriting,
'jittyp' for jitty rewriting with prover
--timings[=FILE]
append timing measurements to FILE. Measurements are written to standard error if no FILE is provided
Standard options:
-q, --quiet
do not display warning messages
-v, --verbose
display short intermediate messages
-d, --debug
display detailed intermediate messages
--log-level=LEVEL
display intermediate messages up to and including level
-h, --help
display help information
--version
display version information
AUTHOR
Written by Muck van Weerdenburg, Frank Stappers.
REPORTING BUGS
Report bugs at <http://www.mcrl2.org/issuetracker>.
COPYRIGHT
Copyright (C) 2012 Technische Universiteit Eindhoven.
This is free software. You may redistribute copies of it under the terms of the Boost Software License
<http://www.boost.org/LICENSE_1_0.txt>. There is NO WARRANTY, to the extent permitted by law.
SEE ALSO
See also the manual at <http://www.mcrl2.org/mcrl2/wiki/index.php/User_manual/lps2torx>.
lps2torx mCRL2 toolset 201202.0 (Release) April 2012 LPS2TORX(1)