Operating Systems Solaris [solved] How to blink faulty disk in Solaris hardware? Post 302867125 by manalisharmabe on Wednesday 23rd of October 2013 01:14:00 PM
Old 10-23-2013
Its sun4u Sun Fire V210

But Oracle Engineer said that it is hot swappable.

Moreover do I need to do metadetach and metaclear before removing the old disk? as the disks are mirrored.

I think I can directly remove old disk and insert new disk right?

Please advise, I really want to know this.

Thanks.
 

10 More Discussions You Might Find Interesting

1. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

2. Solaris

Solaris 10 installation issue Error 25: Disk cannot be read - Solved

Hi all, I guess most of you have seen this error message while installing Solaris 10 on an x86 platform. I got the error message while installing from DVD ISO on my home VMWare ESXi server. It took me a long time to figure the exact issue and a subsequent solution. the solution is very... (1 Reply)
Discussion started by: admin_xor
1 Replies

3. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. UNIX for Advanced & Expert Users

[Solved] Add hardware in virt-install command

Hi, Again a question about virt-install. Someone knows how to add hardware in the virt-install command? I put the first disk with --disks path=/.... but I need a second disk and I don't know how to include it? Thanks (2 Replies)
Discussion started by: hiddenshadow
2 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
volreattach(8)						      System Manager's Manual						    volreattach(8)

NAME
volreattach - Reattaches disk drives that have once again become accessible SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...] /usr/sbin/volreattach -c accessname OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the name of the disk group and disk media name at which the disk can be reattached is displayed. DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment. This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical Storage Manager is started, causing disks to enter the failed state. If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the reattach happens before any volumes on the disk are started. The volreattach command is called from the voldiskadm menus as part of disk recovery. The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists. EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned. SEE ALSO
volintro(8), voldiskadm(8), volrecover(8) volreattach(8)