Sponsored Content
Operating Systems Solaris [solved] How to blink faulty disk in Solaris hardware? Post 302867115 by badoshi on Wednesday 23rd of October 2013 12:57:53 PM
Old 10-23-2013
like bartus11 mentioned, this can vary server to server.

In my experience, on newer Sun.Oracle machines, unconfiguring the disk using cfgadm (if possible) will switch the LED to indicate the drive is 'safe to remove'.
This User Gave Thanks to badoshi For This Post:
 

10 More Discussions You Might Find Interesting

1. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

2. Solaris

Solaris 10 installation issue Error 25: Disk cannot be read - Solved

Hi all, I guess most of you have seen this error message while installing Solaris 10 on an x86 platform. I got the error message while installing from DVD ISO on my home VMWare ESXi server. It took me a long time to figure the exact issue and a subsequent solution. the solution is very... (1 Reply)
Discussion started by: admin_xor
1 Replies

3. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. UNIX for Advanced & Expert Users

[Solved] Add hardware in virt-install command

Hi, Again a question about virt-install. Someone knows how to add hardware in the virt-install command? I put the first disk with --disks path=/.... but I need a second disk and I don't know how to include it? Thanks (2 Replies)
Discussion started by: hiddenshadow
2 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
sgpio(1)							   USER COMMANDS							  sgpio(1)

NAME
sgpio - captive backplane LED control utility SYNOPSIS
sgpio [-h] [-V] [[-d|--disk <device>[,<device>...]] | [-p|--port <port>[,<port>...]]] [-s|--status <status>] [-f|--freq <frequency>] DESCRIPTION
Serial General Purpose Input Output (SGPIO) is a communication method used between a main board and a variety of internal and external hard disk drive bay enclosures. This utility can be used to control LEDs in an enclosure. For more information about SGPIO, please consult the SFF-8485 Specification. OPTIONS
-h, --help displays a short help text -V, --version displays the utility and AHCI SGPIO specification -d, --disk disk name of LED location. Names are sda,sdb,sdc,... Multiple names can be provided in a comma-delimited list. -p, --port SATA port number of LED location, can be used if a disk name is no longer valid. 0,1,2,3,... Multiple ports can be provided in a comma-delimited list. -s, --status status of the LED to set. LED status is: locate, fault, rebuild, off -f, --freq Set the frequency at which the LED should blink (in Hz). Frequency should be an integer between 1 and 10. EXAMPLES
Set the locate LED on SDA with an Intel Intelligent backplane: sgpio -d sda -s locate Set the locate LED on SDA to flash at 3 Hz for non-intelligent backplanes: sgpio -d sda -s locate -f 3 Set SATA port 2 with fault at a 3 Hz flash rate: sgpio -p 2 -s fault -f 3 Set disks sda through sdf to fault: sgpio -d sda,sdb,sdc,sdd,sde,sdf -s fault EXIT STATUS
sgpio should return zero when successful. It will return with a non-zero value if there was a failure. AUTHOR
Eric R. Hall <Eric.R.Hall@intel.com> version 0.3 December 2007 sgpio(1)
All times are GMT -4. The time now is 07:31 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy