Sponsored Content
Operating Systems AIX SAN Disk Appearing double in AIX Post 302843788 by filosophizer on Thursday 15th of August 2013 06:07:01 AM
Old 08-15-2013
Smilie no, i got this test san box for testing oracle applications before deploying rman backup.

ok.

Port 0 = FCS0 of Dual Port Fibre Card connected to Controller A
Port 1 = FCS1 of Dual Port Fibre Card connected to Controller B

DS Storage Client Software, in mappings, I can see only one Default Group to which I assigned one disk.



Code:
# lspath -H
status  name   parent

Enabled hdisk8 fscsi0
Enabled dac0   fscsi0
Enabled hdisk9 fscsi1
Enabled dac1   fscsi1

# lsattr -El fscsi0
attach       al           How this adapter is CONNECTED         False
dyntrk       no           Dynamic Tracking of FC Devices        True
fc_err_recov delayed_fail FC Fabric Event Error RECOVERY Policy True
scsi_id      0x1          Adapter SCSI ID                       False
sw_fc_class  3            FC Class for Fabric                   True

# lsattr -El fscsi1
attach       al           How this adapter is CONNECTED         False
dyntrk       no           Dynamic Tracking of FC Devices        True
fc_err_recov delayed_fail FC Fabric Event Error RECOVERY Policy True
scsi_id      0x1          Adapter SCSI ID                       False
sw_fc_class  3            FC Class for Fabric                   True

# lspv

hdisk8          none                                None
hdisk9          none                                None


# chdev -l hdisk8 -a pv=yes
hdisk8 changed
# chdev -l hdisk9 -a pv=yes
hdisk8 changed

# lspv

hdisk8          00c7780e803680fd                    None
hdisk9          00c7780e803680fd                    None

# lscfg -vl fcs0
  fcs0             U787B.001.DNW3313-P1-C1-T1  FC Adapter

        Part Number.................03N5029
        EC Level....................A
        Serial Number...............1F7050C060
        Manufacturer................001F
        Customer Card ID Number.....5759
        FRU Number.................. 03N5029
        Device Specific.(ZM)........3
        Network Address.............10000000C9612EFA
        ROS Level and ID............02C82774
        Device Specific.(Z0)........1036406D
        Device Specific.(Z1)........00000000
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........03000909
        Device Specific.(Z4)........FFC01231
        Device Specific.(Z5)........02C82774
        Device Specific.(Z6)........06C12715
        Device Specific.(Z7)........07C12774
        Device Specific.(Z8)........20000000C9612EFA
        Device Specific.(Z9)........BS2.71X4
        Device Specific.(ZA)........B1F2.70A5
        Device Specific.(ZB)........B2F2.71X4
        Device Specific.(ZC)........00000000
        Hardware Location Code......U787B.001.DNW3313-P1-C1-T1


# lscfg -vl fcs1
  fcs1             U787B.001.DNW3313-P1-C1-T2  FC Adapter

        Part Number.................03N5029
        EC Level....................A
        Serial Number...............1F7050C060
        Manufacturer................001F
        Customer Card ID Number.....5759
        FRU Number.................. 03N5029
        Device Specific.(ZM)........3
        Network Address.............10000000C9612EF9
        ROS Level and ID............02C82774
        Device Specific.(Z0)........1036406D
        Device Specific.(Z1)........00000000
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........03000909
        Device Specific.(Z4)........FFC01231
        Device Specific.(Z5)........02C82774
        Device Specific.(Z6)........06C12715
        Device Specific.(Z7)........07C12774
        Device Specific.(Z8)........20000000C9612EF9
        Device Specific.(Z9)........BS2.71X4
        Device Specific.(ZA)........B1F2.70A5
        Device Specific.(ZB)........B2F2.71X4
        Device Specific.(ZC)........00000000
        Hardware Location Code......U787B.001.DNW3313-P1-C1-T2

 

10 More Discussions You Might Find Interesting

1. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

2. AIX

hard disk and san

Hello everyone I got several aix boxes with aix 5.3 I got a ibm san ds4500 My question is How can I do a match between my disks on aix and the san? I try to do a match with the LUN but for example. In my san I got several 1 LUN and on one of my aix box I got this If I type lscfg... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies

3. AIX

AIX 5.2/5.3 - rootvg on SAN disk - pros and cons

We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies

4. Solaris

SAN disk failure

hi all, have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ?? thanks in advance. (3 Replies)
Discussion started by: cesarNZ
3 Replies

5. Filesystems, Disks and Memory

SAN Disk w/o Cluster

Scenario: I've got 2 M5000's connected to a 9985 SAN storage array. I have configured the SAN disks with stmsboot, format and newfs. I can access the same SAN space from both systems. I have created files from both systems on the SAN space. Question: Why can't I see the file created... (3 Replies)
Discussion started by: bluescreen
3 Replies

6. UNIX for Dummies Questions & Answers

SAN and Disk I/O ... do we care?

Hi all, My main function is as a DBA. Another person manages the server and the SAN. I just want to know if I should be worried about high disk I/O or is it irrelevant as the I/O "load balancing" will be "taken care" of by the SAN? For example, I have hdisk1-5 and I can see that there are... (2 Replies)
Discussion started by: newbie_01
2 Replies

7. Solaris

I/O Error on SAN Disk

Hi, I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk. I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error. ... (6 Replies)
Discussion started by: Mack1982
6 Replies

8. AIX

SAN DISK raid level in AIX

Hello All, Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ? Am having AIX 6.1 and EMC clarion 5.5. Regards, Gowtham.G (3 Replies)
Discussion started by: gowthamakanthan
3 Replies

9. AIX

San disk appearing double in old AIX

Hi guys, :) I'm a studient in IT field (AIX) I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00) I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN root@localhost # lscfg | grep hdisk + hdisk7 ... (13 Replies)
Discussion started by: Tharsan
13 Replies

10. UNIX for Beginners Questions & Answers

SAN vs. Local disk.

I am in the market looking to purchase a new E950 server and I am trying to decide between using local SSD drives or SSD based SAN. The application that will be running on this server is read-intensive so I am looking for the most optimal configuration to support this application. There are no... (2 Replies)
Discussion started by: ikx
2 Replies
hbaapi(3C)																hbaapi(3C)

NAME
hbaapi - Fibre Channel Storage Network Industry Association Host Bus Adapter Application Programming Interface (FC SNIA HBA API) DESCRIPTION
The Common HBA API provides a consistent HBA standard interface for accessing information in a Fibre Channel Storage Area Network (SAN) that would be implemented across vendors as a standard 'C' API supported by vendor specific library instances. This API library is thread-safe, but threads should not be cancelled when execution is in the API. The following functions are available in the API for managing a Fibre Channel HBA. This API would be exposed to upper level applications to control SAN functionality. Please refer to for details on structures used. 01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. FCP Information Functions require that the applications calling them have an effective user id as that of the root user (euid = 0). 20. 21. 22. SCSI Information Functions require that the applications calling them have an effective user id as that of the root user (euid = 0). 23. 24. FILES
Contains the related data structures and definitions as in AUTHOR
These APIs were developed by Hewlett-Packard Company. SEE ALSO
HBA_GetVersion(3C), HBA_LoadLibrary(3C), HBA_FreeLibrary(3C), HBA_GetNumberOfAdapters(3C), HBA_GetAdapterName(3C), HBA_OpenAdapter(3C), HBA_CloseAdapter(3C), HBA_GetAdapterAttributes(3C), HBA_GetAdapterPortAttributes(3C), HBA_GetPortStatistics(3C), HBA_GetDiscoveredPortAt- tributes(3C), HBA_GetPortAttributesByWWN(3C), HBA_SendCTPassThru(3C), HBA_GetEventBuffer(3C), HBA_SetRNIDMgmtInfo(3C), HBA_GetRNIDMgmt- Info(3C), HBA_SendRNID(3C), HBA_GetFcpTargetMapping(3C), HBA_GetFcpPersistentBinding(3C), HBA_SendScsiInquiry(3C), HBA_SendReportLUNs(3C), HBA_SendReadCapacity(3C), HBA_RefreshInformation(3C), HBA_ResetStatistics(3C). hbaapi(3C)
All times are GMT -4. The time now is 09:16 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy