Sponsored Content
Operating Systems Solaris Sense key unit attention & iostat hardware and transport errors on SAN disks Post 302836879 by achenle on Wednesday 24th of July 2013 08:40:48 PM
Old 07-24-2013
Are your switches zoned? Or is your SAN set up as "everyone sees everything"?

I wonder if those resets correlate to any server on the SAN rebooting.
This User Gave Thanks to achenle For This Post:
 

9 More Discussions You Might Find Interesting

1. Linux

problem with disks on SAN

Hi I have a linux box attched to a SAN storage from EMC with RAID 5 .I understand that it has 3g cache howver a 20gb file creation takes too much time here are my results any ideas why time dd if=/dev/zero of=disk.img bs=1048576 count=20000 20000+0 records in 20000+0 records out 997.59s... (2 Replies)
Discussion started by: xiamin
2 Replies

2. Solaris

iostat -nE with Hard Errors

iostat -nE returns the followings I want to know what is happening to my StorEDGE A1000? Can someone help me? It is a critical device. (1 Reply)
Discussion started by: nickychung
1 Replies

3. Solaris

Sense Key: Media Error

Hi all, We have below WARNING in /var/adm/messages file from our Solaris server. WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@0,0 (sd0): Error for Command: write(10) Error Level: Fatal Requested Block: 16745265 Error Block: 16745269 Vendor: SEAGATE Serial Number:... (8 Replies)
Discussion started by: summerboy
8 Replies

4. Solaris

SAN DISKS - Number of slices ?

Good morning to one and all :-) Thank god its Friday, as its bee na rubbish week for me ! So, a quick question. Disks ! Ive got a few local disks, and a few SAN disks used on my solaris server. Whats confusing me, and Im not sure if there's an issue at the SAN end, or my end, regarding the... (3 Replies)
Discussion started by: sbk1972
3 Replies

5. Solaris

What is the difference between softerrors,harderrors,transport errors?

what is the difference between softerrors,harderrors,transport errors? (3 Replies)
Discussion started by: tv.praveenkumar
3 Replies

6. Solaris

iostat -En errors

I all, I would like to know what are the causes of : -soft error -harderror -transport error and how to avoid and repare them. I got the iostat out put below: atng-mm01% iostat -En | grep -i hard c0t0d0 Soft Errors: 1 Hard Errors: 0 Transport Errors: 0 c0t0d1 ... (3 Replies)
Discussion started by: zaza
3 Replies

7. UNIX for Dummies Questions & Answers

Identify SAN disks

Hello everybody, I'm using the binary inqraid (Linux RHEL) in order to retrieve information about SAN disks. The questions are: Given an LDEV, how do I know if the SAN disk related to this LDEV is being used by the OS? I mean, how can I demonstrate to "Storage department" that all disks of... (4 Replies)
Discussion started by: asanchez
4 Replies

8. Red Hat

Identify SAN disks not in use

Hello, How can I identify SAN disks not in use by the OS? Thank you. (8 Replies)
Discussion started by: asanchez
8 Replies

9. UNIX for Dummies Questions & Answers

transport errors in iostat

Hi Unix experts, I have a question regarding a disk failure seen in "iostat -Enm" output: # iostat -Enm c1t0d0 Soft Errors: 0 Hard Errors: 7 Transport Errors: 9 Vendor: FUJITSU Product: MAU3073NCSUN72G Revision: 0802 Serial No: 0514F005M0 Size: 73.40GB <73400057856 bytes> Media... (5 Replies)
Discussion started by: dyavuzy1
5 Replies
fp(7d)                                                                Devices                                                               fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 05:42 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy