06-28-2013
see if editing /kernel/drv/ce0.conf helps ... reboot the server as required ...
also, check that the switch port the v240 is attached to is actually set to 1000mbs and full duplex ... if yes and the issue is still the same, see if you can move the cable to another port on the switch ... some catalyst switches had a bug that killed a port when it had issues with the negotiation though i am unable to remember the exact cause ...
9 More Discussions You Might Find Interesting
1. IP Networking
I am trying to set an interface to 100/Full, but the command I use are getting rejected. I think it is the last argument, but I don't know how to find the correct values.
I am trying to use the following script, but change hme to le .
echo "Setting hme interface 1: 100mb/full-duplex..."
... (2 Replies)
Discussion started by: bbrandeb49
2 Replies
2. Solaris
Hi Guys,
I need help with ndd.
I was going through network FAQ but i have more questions then answers regarding ndd.
#ndd -set /dev/hme instance 0
#ndd -set /dev/hme adv_100fdx_cap 1
#ndd -set /dev/hme adv_100hdx_cap 0
#ndd -set /dev/hme adv_10fdx_cap 0
#ndd -set /dev/hme adv_10hdx_cap 0... (2 Replies)
Discussion started by: nitinkgoud
2 Replies
3. Solaris
Hello Gurus
I would like to know more about ndd commands related to ethernet(NIC) like how to set link_status, link_speed & link_mode as I know how to check these value. And I also would like to know how to make these setting permanents after reboot as I know that these setting will vanish... (5 Replies)
Discussion started by: amity
5 Replies
4. Solaris
Hi,
I would like to know whether there is any config file that i can refer to for the result of 'ndd -get /dev/tcp tcp_time_wait_interval'?
When i man 'ndd', there is one statement which is -> Each driver chooses which parameters to make visible using ndd. Does it answering my question above... (3 Replies)
Discussion started by: honmin
3 Replies
5. Solaris
Solaris 10 server (SunOS 5.10 Generic_137137_09)
I have a services file configured in /etc in there windows clients connect to my server on port 6034-6037
when I do the following
netstat | grep TestServices
it pulls all the connections active for those ports
so right now I have 10 clients... (3 Replies)
Discussion started by: deaconf19
3 Replies
6. Solaris
Following command was set up in startup script on Solaris 8 servers - improved network transfers of files from one server to the another (doubled transfer speed).
ndd -set /dev/tcp tcp_host_param '10.140.20.10 sendspace 279600 recvspace 279600 timestamp 1'
Now they are getting a new server... (15 Replies)
Discussion started by: RTM
15 Replies
7. Solaris
Hello,
I recently upgraded our system from Solaris 8 to 10. It seems couple of binaries crashed in the new server Solaris 10. Before digging too much on it , from theory it sounds like any binary that is built on Solaris 8 (using gmake) is supposed to be compatible with Solaris 10 , right ?
... (1 Reply)
Discussion started by: sudsa
1 Replies
8. UNIX for Dummies Questions & Answers
Hi,
I'm having issues with sendmail when I try to send host to host mail. I've had to change the "my official domain name" line to mycompany.com to get the mails through the external spam filter, when a mail was sent with hostname.mycompany.com it was blocked. I had to change the Dj macro... (0 Replies)
Discussion started by: elcounto
0 Replies
9. Solaris
Hi,
Recently, I had to disable autoneg in one of my servers having ixgbe1 interface. While using below command I got "Permission denied" error:
ndd -set /dev/ixgbe1 adv_autoneg_cap 0
On investigating further I found that adv_autoneg_cap is showing as read-only parameter. Although it is... (1 Reply)
Discussion started by: rochitsharma
1 Replies
LEARN ABOUT DEBIAN
fence_vixel
fence_vixel(8) System Manager's Manual fence_vixel(8)
NAME
fence_vixel - I/O Fencing agent for Vixel FC switches
SYNOPSIS
fence_vixel [OPTION]...
DESCRIPTION
fence_vixel is an I/O Fencing agent which can be used with Vixel FC switches. It logs into a Vixel switch via telnet and removes the spec-
ified port from the zone. Removing the zone access from the port disables the port from being able to access the storage.
fence_vixel accepts options on the command line as well as from stdin. fenced sends parameters through stdin when it execs the agent.
fence_vixel can be run by itself with command line options which is useful for testing.
After a fence operation has taken place the fenced machine can no longer connect to the Vixel FC switch. When the fenced machine is ready
to be brought back into the GFS cluster (after reboot) the port on the Vixel FC switch needs to be enabled. In order to do this, log into
the Vixel FC switch. Then go to:
config->zones->config <port> <comma-separated-list-of-ports-in-the-zone>
Then apply
Consult the Vixel manual for details
Vendor URL: http://www.emulex.com
OPTIONS
-a IPaddress
IP address of the switch.
-h Print out a help message describing available options, then exit.
-n port
The port number to remove zoning from on the switch.
-p password
Password for login.
-S path
Full path to an executable to generate the password for login.
-V Print out a version message, then exit.
STDIN PARAMETERS
agent = < param >
This option is used by fence_node(8) and is ignored by fence_vixel.
ipaddr = < hostname | ip >
IP address or hostname of the switch.
passwd = < param >
Password for login.
passwd_script = < param >
Full path to an executable to generate the password for login.
port = < param >
The port number to remove zoning from on the switch.
SEE ALSO
fence(8), fence_node(8)
fence_vixel(8)