The scenario in the oracle t4-1 hardware with solaris 10 is as follows:
1. The initial install on the server was performed with an incorrect disk layout.
2. New disks were ordered and slot into the server.
3. The disks are allocated a controller and a disk number based on the disk or replacement disk WWN.
4. This allocation is dependent on the disk not on the slot.
5. The install on the server requires the slots and the controller and the disk allocation to be different than the original install
6. The disk allocation is at a lower level than the operating system and despite several installs of the operating system and attempts to manual configure/unconfigure the disks this has not been possible
I need to reassign the controller numbers for my disks.
Currently, they are like this:
but I would like them to be like this:
i.e. i want to swap around the position of disk 1 and disk 2.
Hello all,
How does the Solaris identifies the controller subscript ? ( like c0txdxs0 or c1txdxsx ?? )
I have a unix box ( Ultra 30) running with 2.5.1.
When I connected an external hard disk to the on-board scsi port, it got identified as c0t1dxsx...
(... (1 Reply)
Hi,
I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below:
/pci@8,600000/SUNW,qlc@2
LiD HA LUN --- Port WWN --- ----- Disk description -----
0 0 0 ... (1 Reply)
Dear Solarizer,
If i have a disk let say like this c1t0d0s0
How to change the controller to be come example : c3t0d0s0
Thanxs For your replay
Regads,
tpx (3 Replies)
hi...
i hav a problem to install sco unix
while installing sco unix 5.0.5 in acer altos with hardware raid
am getting error
"Warning HD: no root disk controller was found
system error 5: while getting fs type
flushing controller: DAC960PRL cache done."
i hav use the following... (18 Replies)
Replace an unknown status controller on HP FC60 disk array
Author:JoyOnline JoyChangLu@gmail.com
Trouble description:
The users detected that the status of controller at A is unknown.
Analysis and diagnostic:
Physical observed all leds on enclosure of disk array is normal.
The... (4 Replies)
I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd.
I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
hi all
i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online... (2 Replies)
So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller.
First, I downloaded the megasas driver from SCO and installed it on the old system.
Then I created a new Microlite Edge emergency boot cd with the new driver on it.
I... (2 Replies)
I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all.
How shall I solve this problem? I am thinking of booting from... (2 Replies)
Hi,
I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error:
WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1):
SCSI transport failed: reason 'reset': retrying... (15 Replies)