06-04-2013
This is quite involved.
There is major documentation that exists on this which I have somewhere. What major documentation have you already got? Please detail.
If you don't have much I will find what I have and upload it but will need to acknowledge all necessary copyrights and check that moderators are okay with that.
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
hi,
i have a volume on a LUN of an EMC-storage and i need to increase the
size.
i could increase the size of the LUN on the EMC, i could increase the
size of the disk for solaris, but how can i tell the veritas volume
manager that the disk is larger now?
what i've done:
1. LUN on EMC
2.... (3 Replies)
Discussion started by: pressy
3 Replies
2. Solaris
Hi,
I have a nasty little problem with my disks on my system
My system configuration is as follows
Sunv890 with sunos 9 connected tot a IBM6800 SAN using a 2port 2 GB qla2342 adapter.
We have bought a EMC SAN. The company who sold us the san, said that it would be no problem connecting the... (10 Replies)
Discussion started by: orac
10 Replies
3. Solaris
Hi,
Quick question if anyone knows this. Is there a command I can use in Veritas Volume manager on Solaris that will tell me what the name of the SAN I am connected to? We have a number of SANs so I am unsure which one my servers are connected to. Thanks. (13 Replies)
Discussion started by: gwhelan
13 Replies
4. Solaris
Hi
Can anyone suggest me some documents for EMC clarion documents which I am going to use in the servers with solaris environments. (1 Reply)
Discussion started by: ningy
1 Replies
5. UNIX for Advanced & Expert Users
I have seen a few threads / posts on the forum's but nothing specific to what Iam after. So Iam hoping you can help.
Issue : Iam hoping to remove unused emc luns from my solaris servers , T2000 (5.10 Generic_142900-02). I have a list of the process I have followed for the removal of the luns.... (3 Replies)
Discussion started by: furby
3 Replies
6. Linux
Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
echo "1" > /sys/class/fc_host/host<n>/issue_lip
and
echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies
7. Solaris
The Storage Admin presents a clone of a LUN, on the source side the device is under VxVM control, assuming that on the target side we have scanned the new cloned LUN at the OS level (solairs), from there on how do we initialize and mount the new volume.
Please give some guidence on this or a... (1 Reply)
Discussion started by: Tirmazi
1 Replies
8. Solaris
Hi All,
I have server : Sun-Fire-V490 configured with Solaris 10 zfs
..
and I have configured three mirror the third one from EMC
storage.
root@server # zpool status -v
pool: rpool
state: ONLINE
status: The pool is formatted using an older on-disk format. The pool can
... (8 Replies)
Discussion started by: top.level
8 Replies
9. AIX
we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
lsdev(1M) lsdev(1M)
NAME
lsdev - list device drivers in the system
SYNOPSIS
driver | class] block_major] char_major] major] [major ...]
DESCRIPTION
The command lists, one pair per line, the major device numbers and driver names of device drivers configured into the system and available
for invocation via special files. A in either the block or character column means that a major number does not exist for that type.
If no arguments are specified, lists all drivers configured into the system.
If the option is specified, will not print a heading. This option may be useful when the output of will be used by another program.
The and options are used to select specific device drivers for output. If more than one option is specified, all drivers that match the
criteria specified by those options will be listed. These search options are divided into two types: name search keys (the and options)
and major number search keys (the and options). If both types of options are present, only entries that match both types are printed. The
same type of option may appear more than once on the command line with each occurrence providing an ORing effect of that search type. The
and options may not be specified at the same time.
The ability to process major arguments is provided for compatibility and functions like the option.
Options
List device drivers that match
class.
List device drivers with the name
driver.
List device drivers with a block major number of
block_major.
List device drivers with a character major number of
char_major.
List device drivers with either a character
major number or block major equal to major.
DIAGNOSTICS
The and options may not be specified at the same time.
A major number is malformed or out of range.
EXAMPLES
To output entries for all drivers in the class:
To output entries that are in the class that have either a block or character major number of
To get the character major number of into a shell environment variable:
WARNINGS
Some device drivers available from the system may be intended for use by other drivers. Attempting to use them directly from a special
file may produce unexpected results.
A driver may be listed even when the hardware requiring the driver is not present. Attempts to access a driver without the corresponding
hardware will fail.
only lists drivers that are configured into the currently executing kernel. For a complete list of available drivers, please run (see
sam(1M).
DEPENDENCIES
Since relies on the device driver information provided in a routine, may not list drivers installed by other means.
AUTHOR
was developed by HP.
SEE ALSO
sam(1M).
Section 7 entries related to specific device drivers.
lsdev(1M)