05-17-2013
Quote:
Originally Posted by
lchunleo
hi all,
kindly help in this matter. Can i check anyone has any experience in removing the CPU fan from its chassis? my fan is spoilt and i wish to replace with other type. See picture below..
---------- Post updated at 05:15 PM ---------- Previous update was at 05:12 PM ----------
this is the cPU fan for HP R390
Rather than asking in forums it would be easy for you to talk with the customer care team.
Check which is the mother board / processor company. Just browse for their customer support. Make a call.
7 More Discussions You Might Find Interesting
1. BSD
Hi all,
Is there any way that I can get some control over th fan in my Evo N400C laptop running OpenBSD 4.0?
Right now the fan is running constantly and it woulf be nice if it could be quiet sometime. (1 Reply)
Discussion started by: Timmy66
1 Replies
2. Hardware
Recently the rear fan assembly of one of our T2000 servers went faulty. I could replace it immediately with the one from a currently powered off standby machine. But now this one has to be replaced.
So I got a quote from our supplier who charges EUR 776 for a new spare part or EUR 405 (all... (0 Replies)
Discussion started by: hergp
0 Replies
3. What is on Your Mind?
I just ordered a Mini-Box M350 with a Mini-ITX Intel DM510MO motherboard.
NO FAN!
I've come to hate the wine of spinning mechanisms in PCs in my quiet home. This one is for surfing the web in my living room (instead of using this laptop), so it doesn't really need much power. If I do... (1 Reply)
Discussion started by: KenJackson
1 Replies
4. Solaris
would Solaris 10 shutdown automatically if both CPU fans fail? (7 Replies)
Discussion started by: orange47
7 Replies
5. Hardware
Hi all,
it is me again..now my HP J6000 fan is spoilt. Based on the error, i suspected it is Fan 1 in the power supply, however there is 3 fans in the power supply, how do i know which is Fan 1?
Thanks for your response
regards (2 Replies)
Discussion started by: lchunleo
2 Replies
6. Solaris
Hey,
I have a V210 with a failed CPU fan.
The temperature is currently at 84C and I've been asked to wait a few weeks before replacing as its a production system and it cant be shut down yet.
Is it too hot? Do I risk killing the CPU at this temp?
Its been like this for a few weeks now... (5 Replies)
Discussion started by: magarvo
5 Replies
7. Solaris
Hi all,
I made some calculations and it seems that fans are working more than they supposed to keep the internals at the specified values. Is there a way to adjust this ?
I have 2 approaches ;
-from ALOM sc|ok prompt
-from Solaris 10
or
-from a HW Switch
I am pretty sure that... (5 Replies)
Discussion started by: y33t
5 Replies
LEARN ABOUT DEBIAN
mrtg-sensors
MRTG-SENSORS(1) MRTG helper utilities MRTG-SENSORS(1)
NAME
mrtg-sensors - Returns data from lm-sensors
SYNOPSIS
mrtg-sensors [-m multiplier] chip label [chip label]
DESCRIPTION
mrtg-sensors uses the lm-sensors library to query various system sensors for information such as temperature, fan speed, etc. The output is
written in a form useful as input for the mrtg utility.
Up to two pairs of chips and labels may be specified. The first is used for the incoming data value in mrtg, while the second is used for
the outgoing data value. Of course, they need not correspond to incoming or outgoing data, that is merely what mrtg expects.
"chip" is the name of the chip to query, and "label" is the label of the piece of information that should be queried from the given chip.
sensors(1) can be used to look up all available chips and labels on your system.
Wildcards may be used in chip names, but only the first matching chip will be queried.
If you use the special name "dummy" as a chip name, nothing will be queried, and a value of zero will be sent to mrtg.
-m is the multiplier to be used in the output. The default multiplier is 1. Note that you may find it more useful to use sensors.conf(5) to
set global multipliers for sensors.
EXAMPLES
mrtg-sensors dummy dummy adm9240-* fan2
Get the speed of fan #2 from the adm9240 chip.
mrtg-sensors -m 0.5 adm9240-* fan1 adm9240-* fan2
Get the speeds of both fan #1 and fan #2, halfing both.
mrtg-sensors -m 2 dummy dummy adm9240-* temp
Get the cpu termerature, and double it.
SEE ALSO
sensors(1)
sensors.conf(5)
AUTHOR
mrtg-sensors was written by Joey 'no pseudo-code' Hess <joeyh@debian.org>.
mrtgutils 0.1 2001-03-04 MRTG-SENSORS(1)