Sponsored Content
Operating Systems Solaris Connect using ALOM to Sun Fire V210 Post 302799831 by danijeljames on Sunday 28th of April 2013 12:03:25 AM
Old 04-28-2013
Thank you for pointing me to that info. It seems to be clearing up for me a bit.

I do however have a few more questions;

#1 Can I use my MacBook with the CISCO cable, having the RS-232 end in the back of the V210 and the eth0 end of the cable in the Ethernet port of my Mac, manually set an IP and use the command
Code:
telnet 10.20.30.40:10000

or will that not work?

#2 Failing that, could I use a USB to RS-232 adapter with the CISCO cable and plug the USB into my MacBook and then use some magical command in terminal to telnet via the USB instead or will that not work?

#3 Is this image the CISCO cable that we are referring to?

Image

If I can't use my MacBook to do this, I'm already scouring for an older crapolá laptop that I can whack WinXP on there. I tested out HyperTerminal in Parallels on OSX, and it is easy to follow, but I think because my computer doesn't have a serial port, it wouldn't give the option I needed to generate a faux connection.

Last edited by danijeljames; 04-28-2013 at 01:05 AM.. Reason: added last line of text
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire v210 display card

hi all, how can install a display card on a sun fire v210. regards. marcel (2 Replies)
Discussion started by: marcelious
2 Replies

2. Solaris

how to connect to alom

Hello Guys, I am working with sunfire V480 and wants to know how to connect to alom. Can you please guide? (7 Replies)
Discussion started by: mokkan
7 Replies

3. Solaris

Sun Fire 280R Sun Solaris CRT/Monitor requirements

I am new to Sun. I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor? Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies

4. Solaris

Alom Sun V240

hallo anybody know how to set alom mail alerty server with yahoomail ? thank u?where i can find mail server address for yahoomail?thank (1 Reply)
Discussion started by: yanto85
1 Replies

5. Solaris

ALOM wont work when KVM connected to Sun Fire V440 server

Hi, I was asked to connect a KVM screen to a Sun Fire V440 last night so I connected it up but no joy and nothing on the KVM screen. I was told that a reboot may fix the problem so connected to the ALOM and rebooted. On the plus side, the KVM screen now works but I lost the ALOM connection. ... (0 Replies)
Discussion started by: jimmy54321
0 Replies

6. Solaris

Booting error in Sun V210

Sun Fire V210, No Keyboard Copyright 1998-2003 Sun Microsystems, Inc. All rights reserved. OpenBoot 4.13.2, 4096 MB memory installed, Serial #61203679. Ethernet address 0:3:ba:a5:e4:df, Host ID: 83a5e4df. Boot device: net File and args: 100 Mbps FDX Link up Timeout waiting for... (5 Replies)
Discussion started by: Mrudhul
5 Replies

7. UNIX for Dummies Questions & Answers

New to Forum & Sun Surefire V210 Access

Purchased a Sun Surefire V210 Server off eBay. Unable to Access the Terminal Mode via the Terminal MGT. Using Windows 7 home, and downloaded the ConEmu. The ConEmu brings up a Command line on the PC, and that's it. Being new to all this, I was expecting a Login prompt to pop up. Read the... (22 Replies)
Discussion started by: screenprintr
22 Replies

8. Solaris

Sun Fire V210 CPU Fan Temp too high?

Hey, I have a V210 with a failed CPU fan. The temperature is currently at 84C and I've been asked to wait a few weeks before replacing as its a production system and it cant be shut down yet. Is it too hot? Do I risk killing the CPU at this temp? Its been like this for a few weeks now... (5 Replies)
Discussion started by: magarvo
5 Replies

9. Solaris

Sun v215 ALOM Reset

Hi all, I got a v215 but the login credentials are unknown. I plug the serial management RS232-RJ45 and get the output on the terminal. I reseted NVRAM and battery but I can't use the default login still. After these operations the output from boot is as such ; ALOM POST 1.0 Status =... (21 Replies)
Discussion started by: y33t
21 Replies

10. Solaris

Any hope for this bootlooping Sun V210?

Hi, First post here! I have a Sun V210 that I use occasionally for build testing things big-endian. I switched it on the other day, at it aint comin' up. I was wondering if anyone on this fine forum knows if it can be brought back from the dead. With the SCC card in, and conencted to... (22 Replies)
Discussion started by: vext01
22 Replies
APCSMART-OLD(8) 						    NUT Manual							   APCSMART-OLD(8)

NAME
apcsmart-old - Driver for American Power Conversion Smart Protocol UPS equipment SYNOPSIS
apcsmart-old -h apcsmart-old -a UPS_NAME [OPTIONS] Note This man page only documents the hardware-specific features of the apcsmart-old driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
apcsmart-old should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and Back-UPS Pro lines. The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible. Some older hardware may only report a handful of variables. This is usually not a bug--they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.networkupstools.org/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0 soft shutdown or powerdown, depending on battery status 1 soft shutdown followed by powerdown 2 instant power off 3 power off with grace period 4 "force OB" hack method for CS 350 Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. Mode 4 exploits an oddity in the CS 350 models since they only seem to support the S command, but then only when running on battery. As a result, the driver will force the UPS to go on battery if necessary before sending the shutdown command. This ensures that the load gets reset. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. APC UPS models with both USB and serial ports require a power cycle when switching from USB communication to serial, and perhaps vice versa. AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the original apcsmart driver by Russell Kroll). This driver was called newapc for a time and was renamed in the 1.5 series. In 2.6.2 the driver was renamed to apcsmart-old, being superseded by updated version with new features. SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 APCSMART-OLD(8)