03-27-2013
just a cable
Actually, cable problems are not product related. I used to solder my own - still have cable and various 9 and 25 pin plugs for making them.
Once properly cabled systems that can be started via the serial port are extremely flexible. I manage 4 different systems - power on remotely, via serial cables - as this can be automated with "expect".
Here is an easy cut/paste script for powering on a POWER5/6/7 system using expect:
HOWTO: POWER on using EXPECT
This User Gave Thanks to MichaelFelt For This Post:
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi
I need to access files from a specific folder of a Linux system from an another Linux System Remotely.
I know how to, Export a folder on One SCO System & can access the same by using Import via., NFS in the Sco Unix SVR4 System using the scoadmin utility.
Also, I know to use mount -t ... (2 Replies)
Discussion started by: S.Vishwanath
2 Replies
2. Solaris
Good morning,
I have a solaris 8 machine (Sunblade 1000) that is configured with NIS, I have checked everything I can think of to make sure everything is correctly configured which it appears it is but when I try to log into CDE it says it is unable to access my home area and it also does the... (1 Reply)
Discussion started by: Mr Pink
1 Replies
3. Solaris
Hi,
I have two Sun Fire V490 with Solaris 10 5/08, FC switch and two Sun StorageTek 3500 FC arrays. Each array is connected to switch and to one server at a time. In the last week I installed Solaris 10 5/08 on both servers and set up Sun Cluster, version 3.2. At wednesday all was fine - all... (7 Replies)
Discussion started by: Sapfeer
7 Replies
4. Shell Programming and Scripting
I am unable to access the value set inside the loop from outside loop .
Thought of taking this to forum , I had seen other replies also , where a pipe takes the execution to another shell and mentioned thats the reason we do not get the variable outside loop . But I am getting an issue and I am... (1 Reply)
Discussion started by: Armaan_S
1 Replies
5. Solaris
Hi,
I am refered to see Infodoc 80854. but I am not able to access from sun.com. Is there any precedure to view these?. Please guide me.
Thanks in advance. (1 Reply)
Discussion started by: bpsunadm
1 Replies
6. HP-UX
hi friends,
I am using hp unix HP-UX B.11.11 .. Generally i do the compression to maintain the space availability . To compress the files first i used the TAR to collect all the files. it has done fine. when i am using command ls in the folder which has TAR file , it shows the TAR... (2 Replies)
Discussion started by: rdhaprakasam
2 Replies
7. AIX
Hi,
I have tried to setup the console on a Power5 9131-52A type IBM Server. On the back there are 2 RS-232 ports labeled T1 T2. I am going under the assuming that these are the serial ports (Normally the serial ports are S1 S0). When I finish assigning the console under smit, I get no response... (3 Replies)
Discussion started by: mrmurdock
3 Replies
8. AIX
I have recently aquired the following machine:
IBM,9113-550
Up until yesterday we could connect a dumb terminal to serial port 1 and get console login. However the dumb terminal died. We are now using a laptop with a null modem cable attached to serial port 1. This works perfectly for all of... (1 Reply)
Discussion started by: rsw7724
1 Replies
9. Shell Programming and Scripting
Hi,
i have the following code in which i am passing array tldn in awk using -v option & despite of that condition is not getting matched,can somebody suggest how to handle shell arrays in awk
tcount=(9875 9667)
awk -F"\t" -v ltldn="${tldn}" 'NR==FNR {POSTPAIDMDNS=$2"|"$3;next}
... (6 Replies)
Discussion started by: siramitsharma
6 Replies
10. AIX
I am running AIX 7.1 and currently we have samba 3.6.25 installed on the server. As it stands some AIX folders are shared that can be accessed by certain Windows users.
The problem is that since Windows 10 the guest feature no longer works so users have to manually type in their Windows login/pwd... (14 Replies)
Discussion started by: linuxsnake
14 Replies
LEARN ABOUT MINIX
optiups
OPTIUPS(8) NUT Manual OPTIUPS(8)
NAME
optiups - Driver for Opti-UPS (Viewsonic) UPS and Zinto D (ONLINE-USV) equipment
NOTE
This man page only documents the hardware-specific features of the optiups driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
optiups was originally written against a PowerES 280es in nut-0.45. It was revised for nut-2.0.1 and tested against a PowerES 420E. It is
expected to work with at least the PowerES, PowerPS, and PowerVS models.
This driver additionally supports a Zinto D from ONLINE USV-Systeme AG because of their very similar commands, but it is unknown if it also
works with other UPS from them.
This driver will not work with the PowerES stock serial cable. You will need to construct your own three conductor cable:
UPS 6 -> PC 3
UPS 9 -> PC 2
UPS 4 -> PC 5
The cable for Online-USV uses pin UPS 7 (not UPS 4) -> PC 5.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file:
status_only
Only poll for critical status information. Without this, optiups (and all NUT drivers) poll all sorts of information from the UPS
fairly often. It is probably not often enough to hurt anything, so this option probably is not very useful, unless you have a flaky
serial connection or a highly loaded machine.
nowarn_noimp
Does not print warnings when the UPS reports that a variable is not implemented or not pollable. Without the option you will get a
message sent to your system logs each time NUT polls the UPS. If you specify nowarn_noimp, this message will only be logged once.
fake_lowbatt
This forces the low battery flag true. Without it, if you want to test your UPS, you will have to unplug it and wait until the battery
drops to a low/critical voltage level before NUT will respond and power down your system. With the flag, NUT should power down the
system soon after you pull the plug. When you are done testing, you should remove this flag.
For basic shutdown configuration testing, the command upsmon -c fsd is preferred.
powerup
Zinto D from ONLINE-USV cannot be identified when switched to standby. Set this flag to allow the driver to power-up your Zinto UPS.
This will also power-up your equipment connected to the UPS!
BUGS
On the 420E, ups.serial and ups.temperature are unsupported features. This is not a bug in NUT or the NUT driver, just the way things are
with this UPS.
AUTHOR
Russell Kroll, Scott Heavner, Matthias Goebl
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 OPTIUPS(8)