Sponsored Content
Operating Systems AIX Unable to access to p5 9131 AIX system Post 302786163 by MichaelFelt on Wednesday 27th of March 2013 03:27:20 AM
Old 03-27-2013
just a cable

Actually, cable problems are not product related. I used to solder my own - still have cable and various 9 and 25 pin plugs for making them.

Once properly cabled systems that can be started via the serial port are extremely flexible. I manage 4 different systems - power on remotely, via serial cables - as this can be automated with "expect".

Here is an easy cut/paste script for powering on a POWER5/6/7 system using expect: HOWTO: POWER on using EXPECT
This User Gave Thanks to MichaelFelt For This Post:
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Need help to access/mount so to access folder/files on a Remote System using Linux OS

Hi I need to access files from a specific folder of a Linux system from an another Linux System Remotely. I know how to, Export a folder on One SCO System & can access the same by using Import via., NFS in the Sco Unix SVR4 System using the scoadmin utility. Also, I know to use mount -t ... (2 Replies)
Discussion started by: S.Vishwanath
2 Replies

2. Solaris

Unable to access home area

Good morning, I have a solaris 8 machine (Sunblade 1000) that is configured with NIS, I have checked everything I can think of to make sure everything is correctly configured which it appears it is but when I try to log into CDE it says it is unable to access my home area and it also does the... (1 Reply)
Discussion started by: Mr Pink
1 Replies

3. Solaris

Unable to access 3500 FC array. Where is the problem?..

Hi, I have two Sun Fire V490 with Solaris 10 5/08, FC switch and two Sun StorageTek 3500 FC arrays. Each array is connected to switch and to one server at a time. In the last week I installed Solaris 10 5/08 on both servers and set up Sun Cluster, version 3.2. At wednesday all was fine - all... (7 Replies)
Discussion started by: Sapfeer
7 Replies

4. Shell Programming and Scripting

Unable to access variable outside loop

I am unable to access the value set inside the loop from outside loop . Thought of taking this to forum , I had seen other replies also , where a pipe takes the execution to another shell and mentioned thats the reason we do not get the variable outside loop . But I am getting an issue and I am... (1 Reply)
Discussion started by: Armaan_S
1 Replies

5. Solaris

unable to access infodoc!!

Hi, I am refered to see Infodoc 80854. but I am not able to access from sun.com. Is there any precedure to view these?. Please guide me. Thanks in advance. (1 Reply)
Discussion started by: bpsunadm
1 Replies

6. HP-UX

Unable to access TAR file

hi friends, I am using hp unix HP-UX B.11.11 .. Generally i do the compression to maintain the space availability . To compress the files first i used the TAR to collect all the files. it has done fine. when i am using command ls in the folder which has TAR file , it shows the TAR... (2 Replies)
Discussion started by: rdhaprakasam
2 Replies

7. AIX

Console Setup for RS-232 port on 9131-52A

Hi, I have tried to setup the console on a Power5 9131-52A type IBM Server. On the back there are 2 RS-232 ports labeled T1 T2. I am going under the assuming that these are the serial ports (Normally the serial ports are S1 S0). When I finish assigning the console under smit, I get no response... (3 Replies)
Discussion started by: mrmurdock
3 Replies

8. AIX

P550 Unable to access Console

I have recently aquired the following machine: IBM,9113-550 Up until yesterday we could connect a dumb terminal to serial port 1 and get console login. However the dumb terminal died. We are now using a laptop with a null modem cable attached to serial port 1. This works perfectly for all of... (1 Reply)
Discussion started by: rsw7724
1 Replies

9. Shell Programming and Scripting

Unable To access array in awk

Hi, i have the following code in which i am passing array tldn in awk using -v option & despite of that condition is not getting matched,can somebody suggest how to handle shell arrays in awk tcount=(9875 9667) awk -F"\t" -v ltldn="${tldn}" 'NR==FNR {POSTPAIDMDNS=$2"|"$3;next} ... (6 Replies)
Discussion started by: siramitsharma
6 Replies

10. AIX

Samba 3.6 on AIX 7.1 - Windows 10 Access to AIX file shares using Active Directory authentication

I am running AIX 7.1 and currently we have samba 3.6.25 installed on the server. As it stands some AIX folders are shared that can be accessed by certain Windows users. The problem is that since Windows 10 the guest feature no longer works so users have to manually type in their Windows login/pwd... (14 Replies)
Discussion started by: linuxsnake
14 Replies
NEWAPC(8)						      Network UPS Tools (NUT)							 NEWAPC(8)

NAME
newapc - Driver for American Power Conversion Smart Protocol UPS equipment NOTE
This man page only documents the hardware-specific features of the newapc driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
newapc should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and Back-UPS Pro lines. Older APC models may work better with the apcsmart driver. The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible. Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.exploits.org/nut/library/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0: soft shutdown or powerdown, depending on battery status 1: soft shutdown followed by powerdown 2: instant power off 3: power off with grace period Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the apcsmart driver by Russell Kroll). SEE ALSO
The core driver: nutupsdrv(8) The apcsmart driver: apcsmart(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ Tue Oct 22 2002 NEWAPC(8)