03-19-2013
Dear Expert,
Please let me know, how can i enable the GUI mode for printers...do i need to uninstall the cups? please update the action plan.
Thank you,
Faiz.
8 More Discussions You Might Find Interesting
1. Linux
Hey,
I definately screwed up my libraries, but I am not sure how. I get this error:
/bin/sh: relocation error: /usr/local/lib/libdl.so.2 symbol _rtld_global_ro, version GLIBC_PRIVATE not defined in file ld-linux.so.2 with link time reference
when I try to even login. I cannot even get to a... (1 Reply)
Discussion started by: farhan00
1 Replies
2. UNIX for Dummies Questions & Answers
Hey,
I definately screwed up my libraries, but I am not sure how. I get this error:
/bin/sh: relocation error: /usr/local/lib/libdl.so.2 symbol _rtld_global_ro, version GLIBC_PRIVATE not defined in file ld-linux.so.2 with link time reference
when I try to even login. I cannot even get... (2 Replies)
Discussion started by: farhan00
2 Replies
3. SuSE
I don't know nearly enough about what versions of Open/Free Linux are available.
I was wondering if someone would create a new poll of all the major recent(ish) distros so we can see the percentage of people's preferred distro? I've only ever used Suse and have been very happy with it, but... (0 Replies)
Discussion started by: Mark Ward
0 Replies
4. Shell Programming and Scripting
Hi,
i need a guide how to write a script which i can do a http request. Let say the request look like below;
http://www.test.com?txid=1&type=service&server=linux
I have a list of "txid" (in *.txt) and need to run all "txid" acordingly. So that mean, every transaction i have to refer "txid"... (7 Replies)
Discussion started by: malaysoul
7 Replies
5. Solaris
hi everyone,
we have solaris 8 in sun v480 server.
it gives this error.
Segmentation Fault(coredump)
can anyone help me in this - urgently.
Regards
Karthik C (8 Replies)
Discussion started by: cksriramchandra
8 Replies
6. UNIX for Advanced & Expert Users
For a few weeks now, on several of our machines, i've been seeing this in /var/log/messages and dmesg:
Nov 14 16:37:48 stg2 kernel: svc: bad direction 256, dropping request
Nov 14 16:37:48 stg2 kernel: svc: short len 4, dropping request
Nov 14 16:38:02 stg2 kernel: svc: bad direction 256,... (2 Replies)
Discussion started by: fishsponge
2 Replies
7. IP Networking
Hi
I want to send non get request for HTTP from linux server.
Please let me knwo how to do that
Thanks
Lakshmikant (0 Replies)
Discussion started by: lakshmikant
0 Replies
8. Ubuntu
Hi
I have a proxy configured on my ubuntu o.s. running on vmware player, but when trying to wgetDownload Nagios Core from SourceForge.net, I have the following error:
failed: Connection refused
I have check on the web, they ask me to run sudo ufw status, but the output is enabled, so what... (0 Replies)
Discussion started by: fretagi
0 Replies
LEARN ABOUT OSX
cups-snmp
cups-snmp(8) Apple Inc. cups-snmp(8)
NAME
snmp - cups snmp backend
SYNOPSIS
/usr/lib/cups/backend/snmp ip-address-or-hostname
/usr/libexec/cups/backend/snmp ip-address-or-hostname
lpinfo -v --include-schemes snmp
DESCRIPTION
The CUPS SNMP backend provides legacy discovery and identification of network printers using SNMPv1. When used for discovery through the
scheduler, the backend will list all printers that respond to a broadcast SNMPv1 query with the "public" community name. Additional queries
are then sent to printers that respond in order to determine the correct device URI, make and model, and other information needed for
printing.
In the first form, the SNMP backend is run directly by the user to look up the device URI and other information when you have an IP address
or hostname. This can be used for programs that need to configure print queues where the user has supplied an address but nothing else.
In the second form, the SNMP backend is run indirectly using the lpinfo(8) command. The output provides all printers detected via SNMP on
the configured broadcast addresses. Note: no broadcast addresses are configured by default.
MIBS
The CUPS SNMP backend uses the information from the Host, Printer, and Port Monitor MIBs along with some vendor private MIBs and intelli-
gent port probes to determine the correct device URI and make and model for each printer.
CONFIGURATION
The SNMP backend reads the /etc/cups/snmp.conf configuration file, if present, to set the default broadcast address, community name, and
logging level. The configuration file is documented in cups-snmp.conf(5). The DebugLevel value can be overridden using the CUPS_DEBUG_LEVEL
environment variable and the MaxRunTime value can be overridden using the CUPS_MAX_RUN_TIME environment variable.
SEE ALSO
backend(7), cups-snmp.conf(5), cupsd(8), cupsd.conf(5), filter(7), lpinfo(8),
http://localhost:631/help
COPYRIGHT
Copyright 2007-2013 by Apple Inc.
8 July 2013 CUPS cups-snmp(8)