03-18-2013
I was waiting for other comments - it has been a while since I have been taught a class using HEA - the HMC code might be improved - but a few years back one of the common things that went wrong was that after a HEA port was configured into promiscuous mode people still tried to use it in multiple partitions and got mixed results.
So, in the HMC you need to open the HEA tab and verify the port is only assigned to a single partition (in this case the VIOS).
I do not have an HMC or a POWER6 system, so I cannot provide commands to check/set HEA at system level and lhea at profile level.
6 More Discussions You Might Find Interesting
1. SuSE
We are using sea application in SUSE linux 10, we are getting the below problem while launching the SEA
Sea is stopped with the message ' sh: /home/pub/bin/awk: cannot execute binary file' in the log window.
Anybody can help me in this issue
Thanks in Advance (1 Reply)
Discussion started by: durgaprasadr13
1 Replies
2. AIX
Hi Guys,
I'm getting the below error while trying to create a SEA adapter in VIOS
$ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
... (4 Replies)
Discussion started by: kkeng808
4 Replies
3. AIX
Hi all,
I set up the following configuration on my system:
- An LPar with a virtual adapter, first one with a vlan id=703 and id port=13.
- The first adapter have to connect to a VIOS in which i configured an SEA.
So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Discussion started by: idro
0 Replies
4. AIX
hi guys
BTW pretty new to VIO
I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8
# lsdev -Cc adapter | grep ent
ent0 Available Logical Host Ethernet Port (lp-hea)
ent1 Available Logical Host Ethernet Port (lp-hea)
ent2 Available 04-20... (8 Replies)
Discussion started by: karlochacon
8 Replies
5. AIX
hello,
what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
Discussion started by: amvineeth
1 Replies
6. AIX
Hello,
POWER7 machine.
4 x 1Gbit port ethernet adapter is dedicated to vios. 8023ad etherchannel is created using those 4 ports. Etherchannel adapter is shared to lpars using SEA.
If I test network performance directly from vios partition (using iperf) I'm geting nice 4Gbit throughput. But if... (3 Replies)
Discussion started by: vilius
3 Replies
LEARN ABOUT HPUX
vparconfig
vparconfig(1M) vparconfig(1M)
NAME
vparconfig - specify the partition mode policy, partition CLM policy, and partition ILM policy for the next system boot
SYNOPSIS
[mode]]
memtype size
DESCRIPTION
The command sets the EFI variable that determines the partition mode on Itanium-based systems and then automatically reboots the system.
The partition mode policy can be vPars or nPars.
In addition, the command sets the partition ILM policy EFI variable (for InterLeaved Memory) and the partition CLM policy EFI variable (for
Cell Local Memory). However, the reboot does not happen automatically. The partition ILM policy or partition CLM policy change will only
occur when you reboot the system using the command.
The default behavior of the command specified without any options is to display the current settings of the partition mode policy, the par-
tition ILM policy, and the partition CLM policy.
This command is only available at the EFI shell if the vPars depot has been installed on the disk.
This command is not supported on PA-RISC platforms.
Options and Arguments
recognizes the following command line options and arguments:
Specifies the partition mode for the next system boot and then automatically reboots the system. The valid values for mode are case-insen-
sitive and The system reboots in the following ways:
o If mode is then after reboot, the system will be in vPars mode.
vPars mode allows you to boot the vPars Monitor and virtual partitions in the next nPartition boot.
o If mode is then after reboot, the system will be in nPars mode.
In nPars mode you cannot boot the vPars Monitor or virtual partitions. However, you can boot HP-UX as a standalone operating
system.
o If is specified with no arguments, then the system reboots with the existing mode.
memtype size
Specifies the desired granularity of Cell Local Memory (CLM) or InterLeaved Memory (ILM) to be set in the appropriate EFI variable
for the next reboot.
memtype is either or
size specifies the desired granularity in megabytes corresponding to memtype. Only a decimal value is allowed to specify the gran-
ule size.
Displays command line options and arguments.
EXAMPLES
Reboot the system to mode.
Reboot the system to mode.
Set the ILM granularity to 128 MB.
Set the CLM granularity to 128 MB.
AUTHOR
was developed by the Hewlett-Packard Company.
SEE ALSO
vparenv(1M).