Operating Systems Linux Ubuntu Ubuntu Install on Sun Fire X4100 network issues Post 302781231 by kaf3773 on Friday 15th of March 2013 06:01:55 PM
Old 03-15-2013
Ubuntu Install on Sun Fire X4100 network issues

Hi

I have two Sun Fire X4100 machines with Ubuntu 12.04 installed on them.
I am able to configure the Net Mgt port with an IP address and access the ILOM from the browser. I can also boot the Ubuntu installed and redirect the output.

The issue i have is that when i configure the network interface(NET0) from Ubuntu and connect an ethernet cable to it i am unable to reach it via ping or ssh. I am also unable to ping out from it. I can confirm that all the network parameters(IP address,Netmask,gateway) are set correctly. And the NET0 interface is connected to the same switch the Net Mgt is connected to. I can ssh and ping the Net Mgt but not the NET0 interface.

I will really appreciate your help. Thanks
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Sun Fire v1280 is crashing

I still haven't got an answer to this question... Excerpt from My SysAd Blog A colleague of mine is having a problem with a Sun Fire v1280 server crashing. He tried Googling for the error message in red but hasn't found anything yet. Your insights would be greatly appreciated. "cannot... (2 Replies)
Discussion started by: esofthub
2 Replies

2. UNIX for Dummies Questions & Answers

Sun Fire 280R

Hello all, I'm lost and can't figure this problem out. I have a Sun fire 280R running Solaris 8. Everything was working great. I have one drive in bay 1(not 0). But when I reboot the system it trys to open files in /dev/rdsk/c1t1d0s0. Should it have been opeing /dev/rdsk/c1t0d0s0, the... (4 Replies)
Discussion started by: larryase
4 Replies

3. Solaris

Sun Fire 280R Sun Solaris CRT/Monitor requirements

I am new to Sun. I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor? Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies

4. Solaris

Does the Sun fire x4100 support HVM?

I have looked all over the bios configuration to enable hardware virtualization and found nothing. Could someone tell if this server support it and if so where I go to enable that feature. By the way this is a x86 server. (0 Replies)
Discussion started by: jsandova
0 Replies

5. Hardware

sun x4100 M2 processors

hi please how to know that a sun x4100 m2 server has one or two processors installed ?? the OS installed on this server is windows 2003 Enterprise Edition. thanks (2 Replies)
Discussion started by: bahjatm
2 Replies

6. Hardware

Sun X4100 graphics

Hello all. I have a requirement to install a aftermarket video card in the server, can you advise what fits? or if there is a sun riser part which convers the PCIx slot to PCIe The unit is a standard x4100 with PCIx slots, not an M2 with the PCIe slots. thanks (4 Replies)
Discussion started by: petebarchetta
4 Replies

7. Solaris

Sun Fire 4800 is not powering-on

I switched on the power to the server. But, the server did not power on i.e., none of the 3 LEDs on the front panel is lighted. (Power supplies are showing only amber LEDs with "Ready to remove" sign). I tried to turn on the power supplies via System Controller menu (platform shell), but it... (6 Replies)
Discussion started by: solind
6 Replies

8. Hardware

Multi-bit ECC Error on X4100 M2 Server Sun Fire

I have a problem, I have been installing Redhat Interprise Linux on X4100 M2 Server, when system is reboot after install, the server is restart (reboot) again (alias unlimited). The bios system show message error "Multi-bit ECC Error" and "bank interleave requested but not enable" I have... (5 Replies)
Discussion started by: hhaswan
5 Replies

9. Solaris

Sun fire x2270

Hello, I have purchaced an old SUn fire x2270 server . I wanted to make ILOM upgrade to the latest version of software : ILOM 3.0.9.18.a r126592 BIOS vers. 2.09 Server 2.2.3 (10-Aug-2018) Because my version is very outdated. But i can't download the updatebecause it's require... (4 Replies)
Discussion started by: LouisLakoute
4 Replies
ping(8) 						      System Manager's Manual							   ping(8)

Name
       ping - send ICMP ECHO_REQUEST packets to network hosts

Syntax
       /etc/ping [ options ] host [ datasize [ npackets ]]

Description
       The  DARPA  Internet  is  a large and complex network of hardware connected together by gateways.  The command utilizes the ICMP protocol's
       mandatory ECHO_REQUEST datagram to elicit an ICMP ECHO_RESPONSE from a host or gateway.	ECHO_REQUEST datagrams (pings) have an IP and ICMP
       header,	followed  by  a  struct timeval, and then an arbitrary number of pad bytes used to fill out the packet.  The length of the default
       datagram 64 bytes, but this may be changed using the command-line option.

       Typing ``ping host'' without any options will either report ``host is alive'' or ``no answer from host''.  To get more statistics  use  the
       -l option or one of the other options.

       When  using  for  fault	isolation,  it should first be run on the local host to verify that the local network interface is up and running.
       Then, hosts and gateways further and further away should be pinged.  The command with options sends one datagram per second and prints  one
       line  of  output  for every ECHO_RESPONSE returned.  No output is produced if there is no response.  If an optional npackets is given, only
       that number of requests is sent.  Round-trip times and packet loss statistics are computed.  When all responses have been received  or  the
       program times out with npackets specified, or if the program is terminated with a SIGINT, a brief summary is displayed.

Options
       -d   Turns on SO_DEBUG flag on the socket.

       -l   Gives more statistics than if is used without options.  Long output.

       -r   Bypasses  the  normal  routing  tables and sends directly to a host on an attached network.  If the host is not on a directly-attached
	    network, an error is returned.  This option can be used to ping a local host through an interface that has no route through  it.   For
	    example, after the interface was dropped by

       -v   Lists ICMP packets other than ECHO RESPONSE that are received. Verbose output.

Restrictions
       This  program is intended for use in network testing, measurement, and management.  It should be used primarily for manual fault isolation.
       Because of the load it could impose on the network, it is unwise to use during normal operations or from automated scripts.

See Also
       netstat(1), ifconfig(8c)

																	   ping(8)
All times are GMT -4. The time now is 05:28 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy