Sponsored Content
Full Discussion: RAID 0 for SSD
Special Forums Hardware Filesystems, Disks and Memory RAID 0 for SSD Post 302780583 by figaro on Thursday 14th of March 2013 06:01:29 PM
Old 03-14-2013
I was wondering about the situation when having two disks in RAID 0 setup, with one distinctly faster than the other. Would the faster disk be overkill, because the speed gain is not utilised to its full advantage? In other words, would software have to be written to use the faster disk more often?
 

8 More Discussions You Might Find Interesting

1. BSD

Using SSD in FreeBSD

Now that SSD drives are becoming mainstream, I had a few questions on installing a SSD drive in a FreeBSD environment. Can FreeBSD be made SSD aware, that is, somehow let FreeBSD know that reads and writes should be limited or deferred to extend the disk's life? Is there a setting for wear... (0 Replies)
Discussion started by: figaro
0 Replies

2. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

3. AIX

SSD with GPFS ?

Hi, does anyone here happen to know if I could run GLVM or GPFS on Solid State Disks? I have a high volume / high transaction Sybase HACMP cluster currently setup with SRDF to the DR datacentre. My business now considers to move everything to SSD storage but we still need to get the data to... (0 Replies)
Discussion started by: zxmaus
0 Replies

4. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

6. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

7. UNIX for Dummies Questions & Answers

What should I format my SSD with?

Hello All, I recently received a new SSD that I am going to use for the purpose of Booting Virtual Machines. I use VMWare Player to boot Windows Guest Operating Systems onto my Linux Laptop. I currently have a SSD drive that I use for this exact same purpose that is formatted as ext3 and I'm... (3 Replies)
Discussion started by: mrm5102
3 Replies

8. Linux

CentOS 6.6 SSD trim on HP DL380 G2 RAID 0

I'm running glusterfs on CentOS 6.6 two nodes, (the SSD (samsung 840 1TB x2) is RAID 0 on the HP DL380 G6) x2, and trimming is not enable on it by checking /dev/sdb1/xxxxx/discard_max_bytes=0. Do I still need trimming? Somehow my filesystem is fine with 35-30% free space and running very fast. ... (1 Reply)
Discussion started by: itik
1 Replies
voldiskadd(8)						      System Manager's Manual						     voldiskadd(8)

NAME
voldiskadd - Adds one or more disks for use with the Logical Storage Manager SYNOPSIS
/usr/sbin/voldiskadd disk-address-list DESCRIPTION
The voldiskadd utility sets up new disks that are added to the system after the initial system installation and configures the disks for use by the Logical Storage Manager. A valid disk label must exist on the disk before using the voldiskadd utility. One or more disks may be specified using a disk-address-list. Disk addresses in the list have the form dskn (for the entire disk) or dsknp (for a specific partition). When specifying multiple disks, use a space between entries. Disk address names relate directly to device names in the /dev/disk directory. For example, here are some valid voldiskadd disk-address-list specifications: # voldiskadd dsk1 # voldiskadd dsk2 dsk3a The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadd. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadd utility prompts the user for a disk group name and disk media name for the disks. If a new disk group name is specified, that disk group is created for the new disks. If no disk group name is specified, the disks are left as unassigned replacement disks for future use. If an existing disk group name is specified, the user is prompted for whether the disks should be designated as spares for the disk group. If a disk is found to already contain non-Logical Storage Manager partitioning, the user is asked whether the disk should be encapsulated. Encapsulation turns each partition of the disk into a volume. A disk should be encapsulated if it contains file systems or data that should not be overwritten. If encapsulation is not desired for a disk, the disk can be initialized as a new disk for use by the Logical Storage Manager. For new disks, all space on the disk becomes free space in the disk's disk group. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. The voldiskadd utility supports the following general classes of actions: Initializing a disk with reserved regions and partitions. Disk initialization is performed by calling voldisksetup command. Adding a disk to an existing disk group. This operation can be performed independently of the initialization of the disk drive to add a disk's storage space to a disk group's free space pool. The volassist command may subsequently allocate from that free space. The disk can also be added as a hot spare device. Creating new disk groups in which to import new disks. If no disk group exists for importing disks, the option of creating the disk group is offered. Encapsulating disks that have exist- ing contents. This is the default action for disks that do not have a valid, existing Logical Storage Manager private region, but that do have a disk label. Encapsulation is performed by calling volencap. Reconnecting a drive that was temporarily inaccessible. This situation is detected automatically, by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the volrecover script. ERRORS
You may receive the following messages when using the voldiskadd command: Initialization of disk device special-device failed. Error: special-device or an overlapping partition is open. This message indicates that the partition you specified or an overlapping partition on the disk is actively in use. The partition could be a mounted UFS or AdvFS filesystem, initialized as an LSM disk or used as a swap device. special-device is marked in use for fstype in the disklabel. If you continue with the operation you can possibly destroy existing data. Would you like to continue?? [y,n,q,?] (default: n) This message indicates that the fstype of a partition or an overlapping partition is set in the disk label. The voldiskadd command prints this message to warn that a disk partition may have valid data which could be destroyed. If you are sure that the disk partition does not have valid data and that the partition can be added to LSM, you can ignore the warning message by entering y at the prompt. The voldiskadd command will proceed to initialize the disk partition and add it to LSM. FILES
A list of disks to exclude from use by voldiskadd. SEE ALSO
disklabel(8), volassist(8), voldisk(8), voldiskadm(8), voldisksetup(8), voldg(8), volintro(8) voldiskadd(8)