03-13-2013
Quote:
Originally Posted by
DukeNuke2
what do you mean with "boot it normally"?
you can use the above commands and try to see the array (or better the volumes created on the array; if there are any) from ok prompt. then
boot the system with "-r" (reconfigure) to create /dev and /devices entries for the new volumes on solaris and check the output of
format.
Quote:
{0} ok probe-scsi-all (Shows attached SCSI devices for all host adapters - Internal and external)
/pci@7c0/pci@0/pci@1/pci@0,2/scsi@2
ERROR: LSI1030 MPT Firmware, issue-scsi-task-mgmt: completed, ioc-status = 004a
ERROR: LSI1030: reset-scsi-bus failed.
ERROR: LSI1030 MPT Firmware, issue-scsi-task-mgmt: completed, ioc-status = 004a
/pci@780/pci@0/pci@9/scsi@0
MPT Version 1.05, Firmware Version 1.09.00.00
Target 0
Unit 0 Disk FUJITSU MAY2073RCSUN72G 0401 143374738 Blocks, 73 GB
SASAddress 500000e0120f0092 PhyNum 0
Target 1
Unit 0 Disk FUJITSU MAY2073RCSUN72G 0501 143374738 Blocks, 73 GB
SASAddress 500000e0120ccbc2 PhyNum 1
Target 2
Unit 0 Disk FUJITSU MAY2073RCSUN72G 0501 143374738 Blocks, 73 GB
SASAddress 500000e01298e002 PhyNum 2
Target 3
Unit 0 Disk FUJITSU MAY2073RCSUN72G 0501 143374738 Blocks, 73 GB
SASAddress 500000e0129acb12 PhyNum 3
Not sure about those errors and it is only showing the 4 internal disks but not any array.
also you can check the storages documentation:
Sun StorageTek 3120 SCSI Array Product Library Documentation
6 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
We just purchased a MOD30 disk array strage system.
We have 15 drives and 2 hot spares.
We're running a database app with 8 data sets.
I'm trying to get the best i/o speed out of my disk configuration.
Right now I have 3 raid5 arrays setup. This seems to offer the same performance as having the... (1 Reply)
Discussion started by: ncmurf00
1 Replies
2. Solaris
hi
i haven't much experience in solaris. I would like to know about storage. how to configure,how it is working etc....can i get any simulator for doing these work? plaese send me the link .
please help me
advance thanks to all (2 Replies)
Discussion started by: sijocg
2 Replies
3. Solaris
Hi,
On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded".
After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK.
I am using CAM... (2 Replies)
Discussion started by: deepaksharma
2 Replies
4. Solaris
I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies
5. HP-UX
hi
I need to check status and configure HP Storage Array device.
HP Storageworks P2000
Please suggest (0 Replies)
Discussion started by: anand87
0 Replies
6. AIX
All,
I have a AIX server with multiple volumes and I need to move them from a legacy storage SAN to a new SAN. We are concerned because to use mirrorvg as we would have to run on a single HBA (one on the old SAN and one on the new). Our other option is to use an appliance to do a block... (3 Replies)
Discussion started by: bkchicago
3 Replies
LEARN ABOUT CENTOS
scsi-rescan
RESCAN-SCSI-BUS.SH(1) User Commands RESCAN-SCSI-BUS.SH(1)
NAME
rescan-scsi-bus.sh - script for adding and removing SCSI devices without rebooting
SYNOPSIS
rescan-scsi-bus.sh [options] [host [host ...]]
OPTIONS
-a, --alltargets
scan all targets, not just currently existing [default: disabled]
-d enable debug [default: 0]
-l activates scanning for LUNs 0--7 [default: 0]
-L NUM activates scanning for LUNs 0--NUM [default: 0]
-w, --wide
scan for target device IDs 0--15 [default: 0--7]
-c enables scanning of channels 0 1 [default: 0 / all detected ones]
-r, --remove
enables removing of devices [default: disabled]
-f, --flush
flush failed multipath devices [default: disabled]
-i, --issue-lip
issue a FibreChannel LIP reset [default: disabled]
-u, --update
look for existing disks that have been remapped
-s, --resize
look for resized disks and reload associated multipath devices, if applicable
--forcerescan
rescan existing devices
--forceremove
remove and readd every device (DANGEROUS)
--nooptscan
don't stop looking for LUNs is 0 is not found
--color
use coloured prefixes OLD/NEW/DEL
--hosts=LIST
scan only host(s) in LIST
--channels=LIST
scan only channel(s) in LIST
--ids=LIST
scan only target ID(s) in LIST
--luns=LIST
scan only lun(s) in LIST
--sync, --nosync
issue a sync / no sync [default: sync if remove]
--attachpq3
tell kernel to attach sg to LUN 0 that reports PQ=3
--reportlun2
tell kernel to try REPORT_LUN even on SCSI2 devices
--largelun
tell kernel to support LUNs > 7 even on SCSI2 devs
--sparselun
tell kernel to support sparse LUN numbering
Host numbers may thus be specified either directly on cmd line (deprecated) or or with the --hosts=LIST parameter (recommended).
LIST: A[-B][,C[-D]]... is a comma separated list of single values and ranges (No spaces allowed.)
SEE ALSO
rescan-scsi-bus.sh Homepage: http://www.garloff.de/kurt/linux/#rescan-scsi
sg3_utils Homepage: http://sg.danny.cz/sg
rescan-scsi-bus.sh 1.57 leden 2014 RESCAN-SCSI-BUS.SH(1)