Operating Systems Solaris Can we configure link based IPMP in private connectivity in Oracle RAC Post 302771036 by DGPickett on Tuesday 19th of February 2013 11:16:47 AM
Old 02-19-2013
Just as easily as it does with any other IP medium. What does it care? It could be PPP or ISDN or hub, and still it is just another IP medium to the same destination. The instructions are how to bond additional IP and names to the path names so communication on the shared IP is sent out on either medium, for both double bandwidth and failover.

Just make sure it is configured with something to watch for outages, as one outage ignored eventually becomes two! RAID5 and the like have this weakness - It starts running on 4 drives but no alert, so nobody ever fixes the fifth drive. A complex medium has many demands n the administrators. Luckily, a cable and two NICs are pretty minimal and reliable. Biggest threat is human tripping on cable!

Remember it is full duplex, so length does not hurt bandwidth, and does very little to latency at a nanosecond a foot or less (speed of light lower in cables due to electromagnetic storage=capacitance and magnetic storage=inductance. The N Ohm rating on the cable says that a light second long cable would draw current like a N ohm resistor for two seconds, and then it depends on what was on the end of the wire. If N ohms load, nothing, else reflected standing wave of voltage (too much resisitance or open) or current (too little resistance or aa short) to destroy transmitter transistors.
This User Gave Thanks to DGPickett For This Post:
 

3 More Discussions You Might Find Interesting

1. Solaris

Link based Active Active IPMP

Hi, I need to configure 4 ip address (same subnet and mask) in one ipmp group (two interfaces) in an active active formation (link based). Can some one provide the steps or a tutorial link. Thanks (2 Replies)
Discussion started by: Mack1982
2 Replies

2. Solaris

IPMP on Private interconnects

I have a Oracle dbase running in a Solaris 10 cluster and have two private interconnects that are being used for communication. Is there any way to connect these two interconnects together using IPMP for redundancy? I've made several attempts with no luck so far and was wondering if anyone had... (17 Replies)
Discussion started by: goose25
17 Replies

3. Solaris

Link Based IPMP on Shared IP Solaris Zone

Hi, This may have already been raised previously so sorry for the duplication. What I want to achieve is have a physical server using link based IPMP setup in the global zone (not problem doing that) and then create a zone set as Shared-IP so when the servers NIC has an issue the IP will... (0 Replies)
Discussion started by: giles.cardew
0 Replies
IE(4)							 BSD/i386 Kernel Interfaces Manual						     IE(4)

NAME
ie -- Ethernet device driver SYNOPSIS
To compile this driver into the kernel, place the following line in your kernel configuration file: device ie Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): if_ie_load="YES" In /boot/device.hints: hint.ie.0.at="isa" hint.ie.0.port="0x300" hint.ie.0.irq="5" hint.ie.0.maddr="0xd0000" HARDWARE
The ie driver provides supports the following 8 and 16bit ISA Ethernet cards that are based on the Intel i82586 chip: o 3COM 3C507 o AT&T EN100 o AT&T Starlan 10 o AT&T Starlan Fiber o Intel EtherExpress 16 o RACAL Interlan NI5210 DIAGNOSTICS
ie%d: unknown board type code %d An i82586 chip was found, but the driver was unable to determine the actual board type during the probe. ie%d: kernel configured maddr %x doesn't match board configured maddr %x The device probe detected a different maddr than the one specified in the kernel configuration file. ie%d: can't find shared memory The device probe could not access the shared memory to determine its size. ie%d: kernel configured msize %d doesn't match board configured msize %d The device probe found a different size for the shared memory than the one specified in the kernel configuration file. ie%d: kernel configured irq %d doesn't match board configured irq %d The device probe detected that the board is configured for a different interrupt than the one specified in the kernel configuration file. ie%d: reset The Intel i82586 had to be reset by the driver. ie%d: transceiver problem The driver has detected a problem with the Ethernet transceiver. This is usually due to a loose or broken trans- ceiver cable when using an external transceiver. When you experience this problem with an on-card transceiver your card may be incorrectly jumpered for to use an external transceiver. Worst case your on-board transceiver may be broken. ie%d: TDR detected an open %d clocks away The driver detected an open circuit in the Ethernet cable. Check your coax cable and terminator resistors. ie%d: TDR detected a short %d clocks away The driver detected a short circuit in the Ethernet cable. Check your coax cable and terminator resistors. ie%d: TDR returned unknown status %x The driver got an unknown status from the card during the Ethernet cable test. ie%d: multicast address setup command failed The card could not be put into multicast mode. ie%d: configure command failed The card refused to respond correctly during configuration. ie%d: individual address setup command failed The programming of the Ethernet (MAC) address failed. CAVEATS
The Racal Interlan NI5210 comes in variants with 8 and 16 kbytes of shared memory. It is strongly advisable to use the 16 kbyte variant. You can upgrade your 8 kbyte card to 16 kbyte by adding an additional RAM chip. SEE ALSO
arp(4), netintro(4), ng_ether(4), ifconfig(8) AUTHORS
The ie device driver was written by Garrett A. Wollman, based on code by William F. Jolitz and Lawrence Berkeley Laboratories. 3C507 support was written by Charles M. Hannum. This manual page was written by Wilko C. Bulte. BSD