02-12-2013
M5000 splitting existing domain
Hi
We have an M5000 with one domain running Sun Cluster on it. We would like to split the domain into two domains. One with the existing Sun Cluster and one with a fresh install. We have 2 CPU Boards (8 CPU) / 4 Mem Boards (64 gb memory) and 2 IOU as well as 4 disks
Is it possible to have such a configuration?
Domain 0
5 CPU
40 GB Memory
1 IO Board
2 Disks
Domain 1
3 CPU
24 GB Memory
1 IO Board
2 Disks
What are the limitations in configuring domains? What is the relationship between memory and cpu?
Is there anything I need to be aware of if I want to split the existing domain?
How would I split the domain without risking to lose the Sun Cluster OS.
Here the showhardconf
Code :
XSCF> showhardconf
SPARC Enterprise M5000;
+ Serial:BCF092004F; Operator_Panel_Switch:Locked;
+ Power_Supply_System:Single; SCF-ID:XSCF#0;
+ System_Power:On; System_Phase:Cabinet Power On;
Domain#0 Domain_Status:Running;
MBU_B Status:Normal; Ver:0201h; Serial:BC0920031A ;
+ FRU-Part-Number:CF00541-0478 07 /541-0478-07 ;
+ Memory_Size:64 GB;
+ Type:1;
CPUM#0-CHIP#0 Status:Normal; Ver:0401h; Serial:PP0910014R ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#0-CHIP#1 Status:Normal; Ver:0401h; Serial:PP0910014R ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#1-CHIP#0 Status:Normal; Ver:0401h; Serial:PP090903WE ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#1-CHIP#1 Status:Normal; Ver:0401h; Serial:PP090903WE ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#2-CHIP#0 Status:Normal; Ver:0401h; Serial:PP091702L0 ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#2-CHIP#1 Status:Normal; Ver:0401h; Serial:PP091702L0 ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#3-CHIP#0 Status:Normal; Ver:0401h; Serial:PP091604HZ ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
CPUM#3-CHIP#1 Status:Normal; Ver:0401h; Serial:PP091604HZ ;
+ FRU-Part-Number:CA06761-D202 E0 /375-3568-05 ;
+ Freq:2.400 GHz; Type:32;
+ Core:4; Strand:2;
MEMB#0 Status:Normal; Ver:0101h; Serial:BF09175UHL ;
+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;
MEM#0A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a66;
+ Type:2A; Size:2 GB;
MEM#0B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a7c;
+ Type:2A; Size:2 GB;
MEM#1A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a51;
+ Type:2A; Size:2 GB;
MEM#1B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a4d;
+ Type:2A; Size:2 GB;
MEM#2A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a7d;
+ Type:2A; Size:2 GB;
MEM#2B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a52;
+ Type:2A; Size:2 GB;
MEM#3A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a4c;
+ Type:2A; Size:2 GB;
MEM#3B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a75;
+ Type:2A; Size:2 GB;
MEMB#1 Status:Normal; Ver:0101h; Serial:BF091863HN ;
+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;
MEM#0A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-482569c2;
+ Type:2A; Size:2 GB;
MEM#0B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a73;
+ Type:2A; Size:2 GB;
MEM#1A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a79;
+ Type:2A; Size:2 GB;
MEM#1B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256a83;
+ Type:2A; Size:2 GB;
MEM#2A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256ac8;
+ Type:2A; Size:2 GB;
MEM#2B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256ac9;
+ Type:2A; Size:2 GB;
MEM#3A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256ac0;
+ Type:2A; Size:2 GB;
MEM#3B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256aab;
+ Type:2A; Size:2 GB;
MEMB#4 Status:Normal; Ver:0101h; Serial:BF091863L9 ;
+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;
MEM#0A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-482569cd;
+ Type:2A; Size:2 GB;
MEM#0B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-482569dd;
+ Type:2A; Size:2 GB;
MEM#1A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256989;
+ Type:2A; Size:2 GB;
MEM#1B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-4825698d;
+ Type:2A; Size:2 GB;
MEM#2A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f7355;
+ Type:2A; Size:2 GB;
MEM#2B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256980;
+ Type:2A; Size:2 GB;
MEM#3A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-4825698b;
+ Type:2A; Size:2 GB;
MEM#3B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-48256981;
+ Type:2A; Size:2 GB;
MEMB#5 Status:Normal; Ver:0101h; Serial:BF09175U6N ;
+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;
MEM#0A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f74e5;
+ Type:2A; Size:2 GB;
MEM#0B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f7398;
+ Type:2A; Size:2 GB;
MEM#1A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f7392;
+ Type:2A; Size:2 GB;
MEM#1B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f73e0;
+ Type:2A; Size:2 GB;
MEM#2A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f734c;
+ Type:2A; Size:2 GB;
MEM#2B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f7397;
+ Type:2A; Size:2 GB;
MEM#3A Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f7395;
+ Type:2A; Size:2 GB;
MEM#3B Status:Normal;
+ Code:ce0000000000000001M3 93T5660QZA-CE6 4151-477f74e2;
+ Type:2A; Size:2 GB;
DDC_A#0 Status:Normal;
DDC_A#1 Status:Normal;
DDC_A#2 Status:Normal;
DDC_A#3 Status:Normal;
DDC_B#0 Status:Normal;
DDC_B#1 Status:Normal;
IOU#0 Status:Normal; Ver:0101h; Serial:BF0905133A ;
+ FRU-Part-Number:CF00541-2240 03 /541-2240-03 ;
+ Type:1;
DDC_A#0 Status:Normal;
DDCR Status:Normal;
DDC_B#0 Status:Normal;
PCI#1 Name_Property:network; Card_Type:Other;
PCI#3 Name_Property:SUNW,qlc; Card_Type:Other;
IOU#1 Status:Normal; Ver:0101h; Serial:BF091760TC ;
+ FRU-Part-Number:CF00541-2240 04 /541-2240-04 ;
+ Type:1;
DDC_A#0 Status:Normal;
DDCR Status:Normal;
DDC_B#0 Status:Normal;
PCI#1 Name_Property:network; Card_Type:Other;
PCI#3 Name_Property:SUNW,qlc; Card_Type:Other;
XSCFU Status:Normal,Active; Ver:0101h; Serial:BF09030HTG ;
+ FRU-Part-Number:CF00541-0481 04 /541-0481-04 ;
OPNL Status:Normal; Ver:0101h; Serial:BF09030CDF ;
+ FRU-Part-Number:CF00541-0850 06 /541-0850-06 ;
PSU#0 Status:Normal; Serial:1357FYG-0848AD00FR;
+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;
+ Power_Status:On; AC:200 V;
PSU#1 Status:Normal; Serial:1357FYG-0848AD00FU;
+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;
+ Power_Status:On; AC:200 V;
PSU#2 Status:Normal; Serial:1357FYG-0848AD00H3;
+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;
+ Power_Status:On; AC:200 V;
PSU#3 Status:Normal; Serial:1357FYG-0848AD00H5;
+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;
+ Power_Status:On; AC:200 V;
FANBP_C Status:Normal; Ver:0301h; Serial:BF0849PR0H ;
+ FRU-Part-Number:CF00541-0848 05 /541-0848-05 ;
FAN_A#0 Status:Normal;
FAN_A#1 Status:Normal;
FAN_A#2 Status:Normal;
FAN_A#3 Status:Normal;
XSCF>
XSCF> showboards -a
XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
----
----------- ---- ---- ----
--------
00-0 00(00) Assigned y y y Passed Normal
01-0 00(01) Assigned y y y Passed Normal
XSCF>
XSCF> showdomainstatus -a
DID Domain Status
00 Running
01 -
02 -
03 -
XSCF>
Thanks a lot for your help.
10 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
I want to look into a folder to see if there are any folders within it. If there are, I need to check inside each folder to see if it contains a .pdf file
So
If /myserver/myfolder/
contains a folder AND that folder conatins a .pdf file
do X
Else
do Z
I may have multiple folders and... (4 Replies)
Discussion started by: crowman
4 Replies
2. Solaris
Pre: no gpasswd/adduser
there is just usermod can be used, also there is no -a option for usermod.
How should I add a user into a group? (4 Replies)
Discussion started by: a2156z
4 Replies
3. Windows & DOS: Issues & Discussions
Dear Expert,
i have linux box that is running in the windows domain, BUT did not being a member of the domain. as I am not the System Administrator so I have no control on the server in the network, such as modify dns entry , add the linux box in AD and domain record and so on that relevant.
... (2 Replies)
Discussion started by: regmaster
2 Replies
4. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
5. Shell Programming and Scripting
I have a source file like this,
L4058S462 34329094 F51010141TK1070000483L4058S462 34329094 0232384840 381892 182 5690
L4058S462 34329094 F51020141FIRST CLEARING, LLC A/C 3432-9094
L4058S462 34329094 F51030141JOHAN HOLMQVIST ... (1 Reply)
Discussion started by: saravanamr
1 Replies
6. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
7. Hardware
Does it Moving the dvd drive domain 0 to domain1 on M5000 sun server (1 Reply)
Discussion started by: rama3479
1 Replies
8. UNIX for Advanced & Expert Users
Hi,
This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1?
... (0 Replies)
Discussion started by: aixlover
0 Replies
9. Solaris
Hi,
This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1?
Thank... (5 Replies)
Discussion started by: aixlover
5 Replies
10. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies