Sponsored Content
Full Discussion: ISO C++ ambiguous error
Operating Systems Linux Red Hat ISO C++ ambiguous error Post 302766233 by dany2704 on Monday 4th of February 2013 12:08:45 PM
Old 02-04-2013
ISO C++ ambiguous error

String.h has the following operator overloading function which is an user defined
Code:
//declaration
int operator==(char *ch)
//definition
int String::operator==(char *ch)
{
        if (strcmp(_text, ch) == 0)
        {
                return TRUE;
        }
        else
        {
                return FALSE;
        }
}

The above operator overloading function is called in the file Sample.c The g++ compiler throws the following error.
Code:
String.h:67: note: candidate 1: int String::operator==(char*)
Sample.c:230: note: candidate 2: operator==(const char*, const char*) <built-in>
Sample.c:249: error: ISO C++ says that these are ambiguous, even though the worst conversion for the first is better than the worst conversion for the second:

i have pasted the caller code (sample.c)
Code:
230  if (String(StrInputBuffer.part_string(4)) == ":86:")
     {
       //statement
     }
249  else if (String(StrInputBuffer.part_string(1)) == ":")
     {
     }

I used the below gnu command to compile the source file
Code:
>g++ -c -g Sample.c -o sample 

compiler version:
Target: x86_64-redhat-linux
gcc version 4.1.2 20080704 (Red Hat 4.1.2-54)
Could you please help me to resolve the issue?

Thanks for looking into this

Last edited by Corona688; 02-04-2013 at 01:17 PM..
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

ambiguous redirect

i have following statement in the script echo -e "$str_XML_col_name:$str_field_type;" >> $i_DC_Key_$i_Tgt_DC_key_Schema here $i_DC_Key is DC key and $i_Tgt_DC_key are the variables............... when i ran the script i am getting error rec_merge.sh: $i_DC_Key_$i_Tgt_DC_key_Schema:... (1 Reply)
Discussion started by: mahabunta
1 Replies

2. Shell Programming and Scripting

getting Ambiguous error on kill -9 @pid from csh

Hello all i have simple script that executing program every 10 seconds im invoke this script as daemon with second script that put it in the background this is my first script (IsAliveTester.csh) #!/bin/csh -f @ iSleep = 10 set processName = "ClientTester" while(1) $processName ... (0 Replies)
Discussion started by: umen
0 Replies

3. Shell Programming and Scripting

`ls -l`: Ambiguous

Hi, I'm trying to code a simple script (c-shell) on a Solaris box and I'm getting an "Ambiguous" error. These are the lines that cause the error: On c-shell: > set var = "" > @ var = `ls -l` `ls -l`: Ambiguous However if I change the second line to: > set var = `ls -l` This works... (2 Replies)
Discussion started by: Guillermo Lopez
2 Replies

4. UNIX for Dummies Questions & Answers

Ambiguous and Command not found Error in UNIX

Hi,All I wrote below script(Example1.sh) and i ran but it giveing error. it's excuted yesterday. SYSTEM_TIME=`date '+%H:%M:%S'` CMP_LOG_TIME=`head -1 runcmp-HINET.log` CMP_ENDED1=`grep 'HINET CMP ended' runcmp-HINET.log` CMP_ENDED2=`echo "HINET CMP ended"` CMP_FAILED2=`echo "HINET... (2 Replies)
Discussion started by: koti_rama
2 Replies

5. Shell Programming and Scripting

Ambiguous and Command not found Error in UNIX

Hi,All I wrote below script(Example1.sh) and i ran but i got error. it's excuted yesterday. SYSTEM_TIME=`date '+%H:%M:%S'` CMP_LOG_TIME=`head -1 runcmp-HINET.log` CMP_ENDED1=`grep 'HINET CMP ended' runcmp-HINET.log` CMP_ENDED2=`echo "HINET CMP ended"` CMP_FAILED2=`echo "HINET CMP... (2 Replies)
Discussion started by: koti_rama
2 Replies

6. Shell Programming and Scripting

Ambiguous output redirect error

Hi everyone, While I was trying to do DATE=`date +"%Y%m%d_%H%M%S"` STARTLOG=$TUXSTDDIR/start_$DATE.log tmboot -y > $STARTLOG 2>&1 I got an error i.e. Ambiguous output redirect error. Here the first part is to boot the account so there is nothing wrong with that.... (6 Replies)
Discussion started by: pareshan
6 Replies

7. Shell Programming and Scripting

ambiguous redirect error

This script has ambiguous redirect error. ... cd $HOME cd folder/work # search all subfolders in work directory find -mindepth 1 -maxdepth 1 -type d | while read directory do CUR_FOLDER="${directory#"./"}" cd $CUR_FOLDER chmod 644 * for ff in *; do if ; then ... (5 Replies)
Discussion started by: candyme
5 Replies

8. Red Hat

How to make boot.iso image from rhel6 installation dvd iso ?

Hello Everyone, Can anyone let me know how to make minimal boot.iso from rhl6 installation dvd iso image. I have a dvd image with me but i want to make just a minimal boot media. Somehow it is not shipped with dvd iso. I know we can download boot.iso from redhat site but is there any anyway we... (5 Replies)
Discussion started by: Rohit Bhanot
5 Replies

9. Shell Programming and Scripting

Ambiguous error

Hello everybody, I just took over this job from someone else and in the past this script they built worked but i recently upgraded from openSuSe 11.4 to 12.1 Now when i run the script i get an ambiguous error at line 25 (the first line after add() ) I have edited out the webpath and any... (1 Reply)
Discussion started by: gumbicus
1 Replies

10. Linux

Ambiguous redirect error and syntax error when using on multiple files

Hi, I need help on following linux bash script. When I linux commands for loop or while loop on individual file it runs great. but now I want the script to run on N number of files so it gives me ambiguous redirect error on line 12 and syntax error on line 22 : (pls help ); #!/bin/bash #... (16 Replies)
Discussion started by: Madhusudan Das
16 Replies
PAGESIZES(5)							File Formats Manual						      PAGESIZES(5)

NAME
pagesizes - HylaFAX page size definitions DESCRIPTION
The pagesizes database defines the page dimensions and guaranteed reproducible areas (GRA) for well-known page sizes. The GRA is the por- tion of the page that is guaranteed to be imaged during facsimile transmission. This region is typically less than the full page dimen- sions because of paper roller contacts and other mechanical aspects of the printing process in a facsimile machine. All HylaFAX programs that require page size information read the information from this database using a page size name. Documents should be prepared such that the full page dimensions are employed with the imaged area contained within the GRA. The system-wide default page size to use in preparing documents for transmission is given by the ``default'' entry in the database. (NB: the default entry should be placed last so that inverse matches find the real page size name and not the default entry.) The page size database is an ASCII file with the following format. Each entry consists of whitespace-separated fields: name abbrev width height gra-width gra-height top-margin left-margin Fields have the following interpretation: name the full name for the page size; e.g. ISO A4; abbrev an abbreviated version of the full name for use in compact listings such as the receive queue listing printed by faxstat(1); width the full width of the page; height the full height of the page; gra-width the width of the GRA; gra-height the height of the GRA; top-margin the margin between the top of the full page and the top of the GRA; left-margin the margin between the left side of the full page the left side of the GRA. The first two fields must be separated from the subsequent fields by a tab character (possibly followed by more whitespace); this is done to easily permit blank characters to be included in names. Otherwise fields can be separated by any amount of any kind of whitespace. Numbers are all base 10 and in basic measurement units (BMU); defined as 1/1200 x 25.4 millimeters for paper output with a scale factor of one. All fields must be present on a single line; otherwise the entry is ignored. Comments are introduced by the ``#'' character and con- tinue to the end the line. Page size database lookups are either by name or by page dimensions. Lookups by name are done by sequentially scanning the entries in the database for the first entry that has a matching abbreviation or substring of the page size name field. The string comparisons ignore case so, for example, ``a4'' would match a full name of ``ISO A4''. Lookups by dimension scan the entire database and return the page with the closest dimensions using a straightforward distance metric. If the difference in dimensions of the closest match is greater than 1/2 inch on each side, then no page entry is returned for a lookup by dimension. SEE ALSO
hylafax-client(1), faxmail(1), faxstat(1), sendfax(1), sgi2fax(1), textfmt(1). December 5, 1994 PAGESIZES(5)
All times are GMT -4. The time now is 03:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy