01-25-2013
If he has no support contract, he can not talk to Oracle support! So all statements of achenle are correct.
10 More Discussions You Might Find Interesting
1. Solaris
I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it.
I have one StorageTek 2540 array that I would like to connect to the T2000.
For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
2. Solaris
We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey.
Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)?
One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies
3. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
4. Solaris
Hi,
I have a simple question on how to correctly disable the matrix?
Looking for the Common Array Manager and I do not see this option...
Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
5. Solaris
Hi peeps,
Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables.
Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies
6. Hardware
Hello all !
I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.
I... (2 Replies)
Discussion started by: acorradi
2 Replies
7. Filesystems, Disks and Memory
Hi,
I have a question about Sun StorageTek Common Array Manager (CAM): What is the concept of 'host'? Is it the hostname of the server that has access to the managed array? If so, can I use its IP instead of its hostname?
I've found a 'host' under CAM called XYZ (See below). In our... (7 Replies)
Discussion started by: aixlover
7 Replies
8. Hardware
Hi all,
My Sun StorageTek 2540 have redundant batteries, but a battery was failed.
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name FRU Alarm State Status Revision Unique Id
-------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies
9. Hardware
Hi Guys and Gals,
Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable.
Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies
10. Solaris
Hi Guys,
I have situation here ...
server M4000 server lost connectivity to storagetek 2540
, storagetek 2540 unable to be ping.From DAS URL the storage is undetected.
Any idea why this is happening. Please share.
Thank you.
Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
LEARN ABOUT HPUX
st_san_safe
st_san_safe(5) OBSOLETED st_san_safe(5)
NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED)
VALUES
Failsafe
Default
Allowed values
Recommended values
or
DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3.
This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When
this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with
a status of
The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files
without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from
HP-UX systems via standard tape commands like which would corrupt a backup in process.
Who Is Expected to Change This Tunable?
Anyone.
Restrictions on Changing
Changes to this tunable take effect immediately.
When Should the Tunable Be Turned On?
This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration.
What Are the Side Effects of Turning the Tunable On?
The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This
behavior prevents the usage of any tape device special file without the no-rewind-on-close option.
When Should the Tunable Be Turned Off?
This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not
function unless it has access to device special files without the no-rewind-on-close option.
What Are the Side Effects of Turning the Tunable Off?
A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard.
SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7).
Tunable Kernel Parameters st_san_safe(5)