01-25-2013
What do you mean by "upgraded the drives"?
Assuming the array is still working, you have three options:
1. Keep using it as-is with no support and without upgrading it (assuming it's still working)
2. Pay for support from Oracle for your existing array so you can get access to updates.
3. Buy another disk array from another vendor.
10 More Discussions You Might Find Interesting
1. Solaris
I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it.
I have one StorageTek 2540 array that I would like to connect to the T2000.
For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
2. Solaris
We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey.
Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)?
One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies
3. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
4. Solaris
Hi,
I have a simple question on how to correctly disable the matrix?
Looking for the Common Array Manager and I do not see this option...
Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
5. Solaris
Hi peeps,
Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables.
Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies
6. Hardware
Hello all !
I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.
I... (2 Replies)
Discussion started by: acorradi
2 Replies
7. Filesystems, Disks and Memory
Hi,
I have a question about Sun StorageTek Common Array Manager (CAM): What is the concept of 'host'? Is it the hostname of the server that has access to the managed array? If so, can I use its IP instead of its hostname?
I've found a 'host' under CAM called XYZ (See below). In our... (7 Replies)
Discussion started by: aixlover
7 Replies
8. Hardware
Hi all,
My Sun StorageTek 2540 have redundant batteries, but a battery was failed.
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name FRU Alarm State Status Revision Unique Id
-------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies
9. Hardware
Hi Guys and Gals,
Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable.
Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies
10. Solaris
Hi Guys,
I have situation here ...
server M4000 server lost connectivity to storagetek 2540
, storagetek 2540 unable to be ping.From DAS URL the storage is undetected.
Any idea why this is happening. Please share.
Thank you.
Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
LEARN ABOUT HPUX
rcsmerge
rcsmerge(1) General Commands Manual rcsmerge(1)
NAME
rcsmerge - merge RCS revisions
SYNOPSIS
rev2] file
DESCRIPTION
incorporates the changes between rev1 and rev2 of an RCS file into the corresponding working file. If is given, the result is printed on
the standard output; otherwise the result overwrites the working file.
A file name ending in is an RCS file name; otherwise it is a working file name. derives the working file name from the RCS file name and
vice versa, as explained in rcsintro(5). A pair consisting of both an RCS and a working file name can also be specified.
rev1 cannot be omitted. If rev2 is omitted, the latest revision on the trunk is assumed. Both rev1 and rev2 can be given numerically or
symbolically.
prints a warning if there are overlaps, and delimits the overlapping regions as explained for the option of co(1). The command is useful
for incorporating changes into a checked-out revision.
EXAMPLES
Suppose you have released revision 2.8 of Assume furthermore that you just completed revision 3.4 when you receive updates to release 2.8
from someone else. To combine the updates to 2.8 and your changes between 2.8 and 3.4, put the updates to 2.8 into file and execute:
Then examine Alternatively, if you want to save the updates to 2.8 in the RCS file, check them in as revision 2.8.1.1 and execute
As another example, the following command undoes the changes between revision 2.4 and 2.8 in your currently checked out revision in
Note the order of the arguments, and that is overwritten.
WARNINGS
does not work for files that contain lines with a single
AUTHOR
was developed by Walter F. Tichy.
SEE ALSO
ci(1), co(1), merge(1), ident(1), rcs(1), rcsdiff(1), rlog(1), rcsfile(4).
rcsmerge(1)